• Title/Summary/Keyword: Steam boiler

Search Result 198, Processing Time 0.041 seconds

Fuzzy self-organizing controller for the industrial boiler system (보일러 제어를 위한 퍼지 자기구성 제어기의 설계)

  • 박태홍;배상욱;박귀태;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.737-741
    • /
    • 1993
  • In this paper, we design the fuzzy logic controller(FLC) for a nonlinear multivariable steam generating unit. Based on the knowledges of operator, the self-organizing controller(SOC) - a kind of FLC - is developed and tested. Both FLC and SOC based on linguistic rules have the advantages of not needing of some exact mathematical model for plant to be controlled. Beside, the SOC modifies the existing control rules by monitoring the control performance. The computer simulations have been carried out for the 200MW steam generating unit to show the usefulness of the proposed method and the effects of disturbances and parameter variations are considered.

  • PDF

Thermodynamic model of one of the super heaters and the related spray in the Nekka power plant and Presenting SCO method to control boiler temperature

  • Zalloi, Mehdi;Barghandan, Saeed;Badamchizadeh, M.A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.129-133
    • /
    • 2005
  • In this paper, first the thermodynamic model is presented to one of the super heaters and sprays of the Nekka power plant and then its unknown parameters are identified according to the registered data of the power plant. SCO control method is introduced to control the external steam temperature of super heater. Finally the conventional method in power plant for controlling external steam temperature of super heater is compared with new method and their performances are presented..

  • PDF

Dehydration and RDF Production of Organic Wastes with Pressurized Hydrothermal Treatment Process (증기가압형 처리공정을 이용한 유기성 폐기물의 건조처리 및 고형연료화)

  • Park, Se-Joon;Choi, Young-Chan;Choi, In-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.439-446
    • /
    • 2009
  • This paper investigates the dehydration and RDF (Refuse Derived Fuel) production of organic wastes, livestock manure and sewerage sludge with pressurized hydrothermal treatment process. The renewable technology for the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The pressurized hydrothermal treatment process promotes to evaporate moisture in the waste after being shortly treated in a reactor, which uses steam and heat supplied by an external boiler. By the pressurized steam, the cell walls of the waste break and effectively release the internal moisture. Then, the dried waste can be mixed with waste vinyls to produce RDF with a higher heating value as high as 6,700 kcal/kg.

Development of Dynamic Simulation Software for Power Plant and its Application to Once-Through Boiler (플랜트 동특성 해석용 소프트웨어 개발 및 초임계압 관류형 보일러에의 적용)

  • Lee, Ki-Hyun;Lee, Dong-Su;Cho, Chang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.656-661
    • /
    • 2000
  • In the recent trend of electric power supply market, a variable pressure operation supercritical once-through steam generator is highlighted as a thermal power plant for cycling load because of its superiority in load regulation. Almost all thermal power plants of the future are expected to be variable pressure operation supercritical once-through units. APESS(Advanced Plant Engineering & Simulation System) is a dynamic simulation software for power plant which is under being developed by Korea Heavy Industries & Construction Co., Ltd. This paper present the introduction of APESS and the result of simulation for variable pressure operation supercritical once-through steam generator.

  • PDF

A Study on Turbine Bypass System in a 500MW Rated Coal Fired Supercritical Thermal Power Plant with Sliding Pressure Operation (변압운전 방식의 500MW 초임계압 석탄 화력발전소 터빈 우회계통에 제어에 관한 고찰)

  • Choi, In-Kyu;Kim, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1663-1664
    • /
    • 2008
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operations and of drum type steam generators with circulation type boilers. But, nowadays almost all of them were of high efficiency, of supercritical pressure, of big capacity, of sliding pressure operations, and of once through type steam generators. Presently built once through boilers introduce turbine bypass systems to variable pressure operation which eliminates unexpected materials in boiler tube during startup, minimizes fuel loss by short startup period and eventually improve both total efficiency and power system stability.

  • PDF

A Study for the Optimal Operating Conditions of the Gas Turbine Based Combined Cycle Cogeneration Power Plant (가스터빈 복합 열병합 발전의 최적 운전조건에 관한 연구)

  • Cho, Young-Bin;Sohn, Jeong-Lak;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1582-1590
    • /
    • 2004
  • The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.

Evaluation of Particle Erosion Resistance for the Boronized Cr/Mo alloy (Boride 코팅의 내입자침식성평가)

  • 이의열;김종하
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.6
    • /
    • pp.371-376
    • /
    • 2002
  • Steam turbine components of power generators are subjected to severe damages from the particle erosion by iron oxides (mainly $Fe_3$$O_4$) which are formed due to the oxidation of boiler tubes, causing high costs for maintaining and repairing. One of the practical ways to minimize the particle erosion is to apply the erosion resistant boride coating on the turbine components which is composed of boride apply. But the evaluation of its performance has not been carried out. A particle erosion tester, which can offer the erosion condition of steam turbine components, was developed to evaluate the performances of the boronized Cr/Mo alloy. The result showed that the boronized Cr/Mo alloy showed superior resistance to particle erosion to the bare Cr/Mo alloy in all test conditions.

Multi-Optimization Study of a Boiler System Using Immune Algorithms (면역 알고리즘을 이용한 보일러 시스템의 다목적 성능 최적화 연구)

  • 김동화;박진일
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.05a
    • /
    • pp.177-181
    • /
    • 2003
  • PID(Proportional-Integral-Derivative)제어기는 제어악고리즘의 단순성과 실 현장에서의 강인성 등으로 산업용 보일러의 제어시스템서 주로 이용되어 왔다. 그러나 다중 루프를 가진 보일러 시스템에서는 루프간의 상호 간섭 영향 등으로 부하 변화에 따라 요구되는 증기(steam)압력, 증기 유량(steam flow)변화 등을 동시에 만족하도록 급수 유량, 연교 유량, 공기 유량 등을 PlH제어기만으로 제어하는 것은 어렵다. 본 연구에서는 보일러 시스템의 다목적 성능 최적화에 각각의 적합도 함수 $f_{a}$ , $f_{b}$, $f_{c}$를 정의하고 면역 알고리즘을 이용해 최적화를 구하고 그 결과에 대한 특성과 유효성을 검토하였다.다.다.

  • PDF

A Study on Characteristics of HRSG Boiler Inner Tube Scale (HRSG 보일러 튜브 내면 스케일의 특성연구)

  • Lee, Seung-Min;MIN, Byung-Yeon;JEONG, Nyeon-Ho
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.82-88
    • /
    • 2012
  • The thickness and chemical composition of oxides on heat recovery steam generator tubes of combined cycle power plant were examined in order to evaluate the corrosion of the tubes. Tubes were removed from the plant after actual operations for 21,482, 42,552 and 56,123 hours respectively. Thickness and growth rate of the oxide scale on reheater inner tube (SA213-T22) were very high compared to those other tubes. The oxide scale was about $250{\mu}m$ thick and uniform. The components of the scale were iron oxides. The oxide scale was mixed oxides consisting of magnetite$(Fe_3O_4)$ and hematite$(Fe_2O_3)$. The oxide on inner tube was removed using many kinds of chemicals and it was found that chelating agents were dissolved faster than other chemicals.

An Investigation on Flow and Structural Characteristics of Heat Exchanger in Rankine Steam Cycle for Co-generation System (기관 폐열 회수를 위한 열교환기의 Baffle 길이 변경에 따른 성능 예측에 관한 수치 해석적 연구)

  • Ryu, Kyuhyenn;Kim, Kusung;Lee, Younghum;Kang, Seokho;Park, Gibeom
    • New & Renewable Energy
    • /
    • v.9 no.4
    • /
    • pp.32-39
    • /
    • 2013
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop is used to recover waste heat from exhaust gas and a low temperature loop is used to recover waste heat from cold engine coolant. This paper has dealt with a layout of low temperature loop system, the review of the velocity contours through numerical analysis. According to the result of analysis, the designed heat exchanger. And comparing with flow analysis results, LT Boiler is safe to operation.