• 제목/요약/키워드: Steam Generator Level Control

검색결과 75건 처리시간 0.027초

Application of Fuzzy Algorithm with Learning Function to Nuclear Power Plant Steam Generator Level Control

  • Park, Gee-Yong-;Seong, Poong-Hyun;Lee, Jae-Young-
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1054-1057
    • /
    • 1993
  • A direct method of fuzzy inference and a fuzzy algorithm with learning function are applied to the steam generator level control of nuclear power plant. The fuzzy controller by use of direct inference can control the steam generator in the entire range of power level. There is a little long response time of fuzzy direct inference controller at low power level. The rule base of fuzzy controller with learning function is divided into two parts. One part of the rule base is provided to level control of steam generator at low power level (0%∼30% of full power). Response time of steam generator level control at low power level with this rule base is shown generator level control at low power level with this rule base is shown to be shorter than that of fuzzy controller with direct inference.

  • PDF

원전 증기발생기 수위제어를 위한 MPC 제어기 개발 (The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

적응제어알고리즘을 이용한 원자력발전소용 증기발생기 수위제어 시스템에 관한 연구 (A study on the microcomputer-based adaptive control system of a steam generator)

  • 배병환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.658-663
    • /
    • 1987
  • The new controller developed here, which is the facility with only one measurement, is a new concept for the level controller of the existing nuclear steam generator. A MACS (Microcomputer-based Adaptive Control System of a Steam Generator) is quite practical and efficient, and has also simple structure and higher flexibility in the installment for actual plant. A key ingredient of this system is adaptive regulator which can calculate adaptive, optimal valve position in response to changes in the dynamics of the process and the disturbances. In spite of many difficulties in the steam generator water level control at low power, it can be concluded from the experimental and simulation results, that the MACS can provide optimal, robust steam generator level control from zero to full power. The amount of the control input effort can be reduced by adjusting the weighting factor. However, the steady state water level errors are generated. To avoid the steady errors, the different adaptive algorithm should be investigated in the future. The 3 second sampling time is acceptable for this system. However, action should be taken to shorten the sampling time for better digital control.

  • PDF

증기발생기 수위제어를 위한 다중 안정화 제어기 설계 (Reliable stabilizing multi-controller for steam generator level control)

  • 권현진;박상현;이상정;함창식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1229-1232
    • /
    • 1996
  • This paper proposes the passive redundancy algorithm of multi-controller structure applicable to the steam generator level control system in the low power operating range. In the passive redundancy scheme of multi-controller structure, two suitable controllers exist if the plant is strongly stabilizable. One of the two controllers can be selected arbitrarily only if it is stable. In particular, this paper shows that the passive redundancy scheme can be efficiently used with PID and GPC control algorithms through simulation studies on the control of the steam generator.

  • PDF

The Level Control System Design of the Nuclear Steam Generator for Robustness and Performance

  • Lee, Yoon-Joon;Lee, Heon-Ju;Kim, Kyung-Yeon
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.157-168
    • /
    • 2000
  • The nuclear steam generator level control system is designed by robust control methods. The feedwater controller is designed by three methods of the H$\infty$, the mixed weight sensitivity and the structured singular value. Then the controller located on the feedback loop of the level control system is designed. For the system performance, the controller of simple PID whose coefficients vary with the power is selected. The simulations show that the system has a good performance with proper stability margins.

  • PDF

저 출력시 증기발생기 수위의 자동제어논리 개발 (Development of an automatic steam generator level control logic at low power)

  • 한재복;정시채;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.601-604
    • /
    • 1996
  • It is well known that steam generator water level control at low power operation has many difficulties in a PWR (pressurized water reactor) nuclear power plant. The reverse process responses known as shrink and swell effects make it difficult to control the steam generator water level at low power. A new automatic control logic to remove the reverse process responses is proposed in this paper. It is implemented in PLC (programmable logic controller) and evaluated by using test equipment in Korea Atomic Energy Research Institute. The simulation test shows that the performance requirements is met at low power (below 15%). The water level control by new control logic is stabilized within 1% fluctuation from setpoint, while the water level by YGN 3 and 4 control logic is unstable with the periodic fluctuation of 25% magnitude at 5% power.

  • PDF

THE MODEL PREDICTIVE CONTROLLER FOR THE FEEDWATER AND LEVEL CONTROL OF A NUCLEAR STEAM GENERATOR

  • Lee, Yoon Joon;Oh, Seung Jin;Chun, Wongee;Kim, Nam Jin
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.911-918
    • /
    • 2012
  • Steam generator level control at low power is difficult due to its adverse thermal hydraulic properties, and is usually conducted by an operator. The basic model predictive control (MPC) is similar to the action of an operator in that the operator knows the desired reference trajectory for a finite period of time and takes the necessary control actions needed to ensure the desired trajectory. An MPC is based on a model; the performance as well as the efficiency of the MPC depends heavily on the exactness of the model. In this study, steam generator models that can describe in detail its thermal hydraulic behaviors, particularly at low power, are used in the MPC design. The design scope is divided into two parts. First, the MPC feedwater controller of the feedwater station is determined, and then the MPC level controller for the overall system is designed. Because the dynamic properties of a steam generator change with the power levels, a realistic situation is simulated by changing the transfer functions of the steam generator at every time step. The resulting MPC controller shows good performance.

원전 증기발생기 수위제어 디지탈화 및 적응에 관한 연구 (A study on the digitalize and application of Steam Generator level control system for nuclear power plant)

  • 문병희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.265-267
    • /
    • 1993
  • A control for Steam Generator (S/C) level is very difficult by automatic control mode but also manual control node during plant start up and/or low power level operation with the analog control system because of a non-nominal process responce. The goal of this study is to improve and computerize and applicate for KO-RI #1 Steam Generator level control system.

  • PDF

A Model Predictive Controller for The Water Level of Nuclear Steam Generators

  • Na, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.102-110
    • /
    • 2001
  • In this work, the model predictive control method was applied to a linear model and a nonlinear model of steam generators. The parameters of a linear model for steam generators are very different according to the power levels. The model predictive controller was designed for the linear steam generator model at a fixed power level. The proposed controller at the fixed power level showed good performance for any other power levels by designed changing only the input-weighting factor. As the input-weighting factor usually increases, its relative stability does so. The steam generator has some nonlinear characteristics. Therefore, the proposed algorithm has been implemented for a nonlinear model of the nuclear steam generator to verify its real performance and also, showed good performance.

  • PDF

PI-신경망 제어기를 이용한 원자력 발전소용 증기 발생기 수위제어 (The level control of Steam Generator in Nuclear Power Plant by Neural Network-PI Controller)

  • 김동화
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.6-13
    • /
    • 1998
  • 본 연구에서는 증기유량, 중기온도 주 급수 온도 및 유량둥과 같은 외란에 의해 증기발생기의 웅축 및 팽창효 과가 발생하여 수위조절에 어려웅이 발생하는 문제를 신경망-PI제어기를 이용해 효과적으로 제어하는 연구를 하였다. 종래의 PI제어기는 저 출력에서 효과적으로 제어 할 수 없어 기동시는 숙련자의 노련한 기술이 필요한데 반해 본 연구에서 적용한 신경망 PI제어기는 Kp,Ti 파라매터를 외란에 영향을 줄 수 있는 파라메터를 고려하여 신경망을 이용해 튜닝함으로서 웅축 및 팽창효과를 줄이고 외란 및 설정치 변경에 대해 효과적으로 제어 될 수 있음을 실험과 시뮬레이션을 통해 확인 할 수 있었다.

  • PDF