• Title/Summary/Keyword: Steady-state operation

Search Result 622, Processing Time 0.023 seconds

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Development of Web-based Power Plant Simulator System (원격 훈련용 발전 시뮬레이터 개발)

  • Byun, Seung-Hyun;Kang, Hae-su;Woo, Joo-Hee;Lee, Jee-Hoon;Kim, Duck-Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.277-283
    • /
    • 2021
  • Power plant simulators have been used for operator training, control verification and engineering verification. In general, simulators can be used in the place where they are installed by only single user group at a time. Considering high cost of simulator development, a lot of available scenarios, the diversity of user level and accessibility based on users' work location, development of simulator system that can be used by multiple user groups regardless of location is required in order to enhance utilization of simulators. In this paper, the simulator system that can be used by multiple user group simultaneously without location limitation is proposed. The simulator system is composed of simulator servers, database servers, HMI servers, a web server, web clients. Simulator server consists of control model, process model that are developed for Circulating Fluidized Bed power plant located overseas. A web server manages user accounts, operation procedures, multiple server access between web client group and simulator server group. In other words, a web server makes a user group select a simulator server at a time. The developed simulator system is integrated after implementing process model, control model, HMI, and web server. Web client systems are installed on local site where power plant is located, while simulator servers, HMI servers, database servers, and a web server are located in KEPCO RI. The developed simulator system is verified by steady-state test, malfunction test and so on via remote access.

A Performance Comparison of DSE-MMA and DQE-MMA Adaptive Equalization Algorithm using Dither Signal (Dither 신호를 이용한 DSE-MMA와 DQE-MMA 적응 등화 알고리즘의 성능 비교)

  • Lim, Seung-Gag;You, Jeong-Bong;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 2022
  • This paper compares the equalization performance of the DSE-MMA (Dithered Signed Error-MMA) and DQE-MMA (Dithered Quantized Error-MMA) adaptive equalization algorithm based on the dither signal in order to reduce the intersymbol interference occurs at communication channel. These algorithm was emerged in ordr to reduction of arithmetic operation than current MMA, it makes the independent and identical distribute the quantized error component by performing the 1 or N bit quautizer after adding the dither singal in obtaining the error signal for adapting process. It is possible to improve the robustness performance of adaptive algorithm, but degrade the MSE performance in steady state by dither signal. The paper directly compare the DSE-MMA and DQE-MMA adaptive equalization performance of the same concept of dithering in the same communication channel and signal to noise ratio by computer simulation. As a result of simulation, the DQE-MMA has more better in the every performance index, equalizer output constellation, residual isi, MSE and SER performance, but not in convergence speed.

Digital Control System Validation using the Simulator Models for 500MW Standard Type Fossil Power Plant (500MW급 표준화력발전소 시뮬레이터 모델을 이용한 디지털 제어시스템 검증)

  • Suh, Jeong-Kwan;Lee, Myeong-Soo;Hong, Jin-Hyuk
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.3
    • /
    • pp.71-79
    • /
    • 2010
  • The simulator models for 500MW fossil power plant have been developed, and interconnected with the turbine control system to test and validate the digital instrumentation & control (I&C) systems before they are implemented in operating power plants. When the performance of a selected digital I&C system is tested, the corresponding simulator model is replaced by the plant digital I&C systems which is considered as a non-tunable system. The input/out variables of simulator models and control systems were mapped using the LabView in interface systems. This paper describes the interconnection method between the simulator model and the digital I&C system, and summarizes the validation test results performed at the condition of steady-state operation, normal evolution, and malfunction. The integrated validation method of digital I&C systems using the simulator models showed that the simulator can be used as a test bed for the implementation of digital I&C systems in power plants.

Development of a New Prediction Alarm Algorithm Applicable to Pumped Storage Power Plant (양수발전 설비에 적용 가능한 새로운 고장 예측경보 알고리즘 개발)

  • Dae-Yeon Lee;Soo-Yong Park;Dong-Hyung Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.2
    • /
    • pp.133-142
    • /
    • 2023
  • The large process plant is currently implementing predictive maintenance technology to transition from the traditional Time-Based Maintenance (TBM) approach to the Condition-Based Maintenance (CBM) approach in order to improve equipment maintenance and productivity. The traditional techniques for predictive maintenance involved managing upper/lower thresholds (Set-Point) of equipment signals or identifying anomalies through control charts. Recently, with the development of techniques for big analysis, machine learning-based AAKR (Auto-Associative Kernel Regression) and deep learning-based VAE (Variation Auto-Encoder) techniques are being actively applied for predictive maintenance. However, this predictive maintenance techniques is only effective during steady-state operation of plant equipment, and it is difficult to apply them during start-up and shutdown periods when rises or falls. In addition, unlike processes such as nuclear and thermal power plants, which operate for hundreds of days after a single start-up, because the pumped power plant involves repeated start-ups and shutdowns 4-5 times a day, it is needed the prediction and alarm algorithm suitable for its characteristics. In this study, we aim to propose an approach to apply the optimal predictive alarm algorithm that is suitable for the characteristics of Pumped Storage Power Plant(PSPP) facilities to the system by analyzing the predictive maintenance techniques used in existing nuclear and coal power plants.

Waiting Time and Sojourn Time Analysis of Discrete-time Geo/G/1 Queues under DT-policy (DT-정책 하에서 운영되는 이산시간 Geo/G/1 시스템의 대기시간과 체재시간 분석)

  • Se Won Lee
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.2
    • /
    • pp.69-80
    • /
    • 2024
  • In this paper, we studied a discrete-time queuing system that operates under a mixed situation of D-policy and T-policy, one of the representative server control policies in queuing theory. A single server serves customers arriving by Bernoulli arrival process on a first-in, first-out basis(FIFO). If there are no customers to serve in the system, the server goes on vacation and returns, until the total service time (i.e., total amount of workload) of waiting customers exceeds predetermined workload threshold D. The operation of the system covered in this study can be used to model the efficient resource utilization of mobile devices using secondary batteries. In addition, it is significant in that the steady state waiting time and system sojourn time of the queuing system under a flexible mixed control policy were derived within a unified framework.

Suggestions for the Activation of the Elementary Science Camp through the Present Status of Operation and Preference Survey (초등과학캠프의 운영 실태와 선호도 조사를 통한 활성화 방안)

  • Kwon, Nanjoo;Kim, Sangyong;Na, Sanghoon
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.306-319
    • /
    • 2010
  • The purpose of this study is to pursue suggestions for the activation of the elementary science camp through the present status of operation and preference survey; examined 50 elementary science camps conducted since year 2004, and surveyed 590 people of students, parents and teachers around Seoul and Gyeonggi province. This study also explores ways of issues and solutions through interviews with five officials of the elementary science camp. This study drew data from the present status of the elementary science camp, the state of camp participation, student's preference, interviews with camp managers. The following are suggestions for the activation of the elementary science camp based on the results of this study; First, the elementary science camp especially in charge of science-related association or office of education should be enlarged, and other private institute or organization should prepare for specialized programs and expert teachers. Second, insufficient camp spot should be solved and participation fee differentials should be alleviated. Third, the period of the camp and its announcement should be various, so that students have more opportunities. In conclusion, managing elementary science camp needs specialism, and continuing effort, because it is related to many important matters such as theme, period, place, participation expenses, guiding teacher, number of student, program organization, student's preference, and method of notice. Therefore, this study insists steady cooperation, continuing endeavor, and appropriate support system for elementary science camps on a nationwide scale.

  • PDF

Performance Improvement of SE-MMA Adaptive Equalization algorithm by Selective Updating (Selective Updating에 의한 SE-MMA 적응 등화 알고리즘의 성능 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2016
  • This paper proposes the SU-SE-MMA algorithm which applying the concept of selective updaing to the SE-MMA that is possible to reduce the intersymbol interference due to distortion occurred at the channel when transmit the nonconstant modulus 16-QAM signal. The SE-MMA emerged for the simplifying the computational operation from the current MMA adaptation algorithm, then it's has the fast convergence speed and has a problem of increase the residual component in the steady state. The SU-SE-MMA performs the selectively tap updating when the distance of equalizer output and specified transmit signal point is greater than the given threshold value and tap updaing does not occurred in the small distance. By this selective updating process, it is possible to more reduction in the computational operation in the propose algorithm. The improved adaptive equalization performance of SU-SE-MMA like as the equalizer output signal constellation, residual isi, MD, SER were confirmed by computer simulation compared to SE-MMA. As a result of simulation, the AV-SE-MMA has better performance in output signal constellation, residual isi and MD compared to the SE-MMA, but it was confirmed that the AV-SE-MMA has similar in the SER performance that means the robustness to the noise.

Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions (정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.52-61
    • /
    • 2005
  • Permeate flux decline in a microfiltration was analyzed by measuring the permeability of bentonite colloidal solution through polyethylene capillary membranes. The flux decline with time was due to the growth of cake layer on the membrane surface and to the pore blocking by particles. As the time approaches to steady state, the permeate flux is almost controlled by the cake filtration model. Faster flux decline at high trans-membrane pressure was attributed to the formation of denser packed cake layer and pore blocking. The ratio of permeate flux to the initial permeate flux, J/J₁, decreased with increasing the trans-membrane pressure, from 45% for 0.5 kg/sub f//㎠ to 38% for 2.0 kg/sub f//㎠. In comparing the ratio of each fouling component to the total fouling for the 0.5 kg/sub f//㎠ TMP condition, complete blocking was 23.4%, standard blocking was about 14.6% and cake filtration was 62.0%, respectively. Permeate flux through the membrane increases with cross flow velocity, and the effect of the variation of velocity is more significant at 1.0 kg/sub f//㎠ rather than at 2.0 kg/sub f//㎠ of the operation pressure. Permeate flux for the membrane having the average pore diameter of 0.34 ㎛ was higher than that for the membrane of 0.24 ㎛ pore size, with the higher flux with the low concentration of feed. On the operation using the membrane of 0.34 ㎛ pore, the pore blocking in the low concentration of 200 ppm is negligible relative to the pore blocking in the 1000 ppm feed.

An Study on the Operation and Current Status of Non-public Records Management in Local Government Archives : Focused on the Seoul Archives and Gyeongnam Archives (지방기록물관리기관의 민간기록관리 운영과 현황에 관한 연구 서울기록원과 경남기록원을 중심으로)

  • Kim, Ji-ho;Youn, Eun-ha
    • The Korean Journal of Archival Studies
    • /
    • no.71
    • /
    • pp.273-309
    • /
    • 2022
  • The discussion on local archives management institutions started in the early 2000s and has been steady. In the law, local records management institutions first appeared in 1999, and in 2007, the establishment of local records management institutions by local governments became compulsory. The archival institutions of local government, however, were actually founded in the Gyeongnam Province, 2018, and in the Seoul City, 2019, over 10 years after the revision of the law. And as of 2021, various local governments, including Gyeonggi-do, are conducting research to establish local archives management institutions. This is the time when domestic records management institutions are introduced in earnest. However, it is still unclear how regional archives will operate in practice, particularly how they will accommodate the management of private archives, which has long been regarded as the mission of regional archives. In this thesis, the past discussions on the local record management institutions will be reviewed focusing on private record management. In this regard, it is intended to examine the current state of private records management of local records management institutions through the current status of local records management institutions in operation, and to seek directions for local records management institutions based on this.