• Title/Summary/Keyword: Steady state line

Search Result 255, Processing Time 0.032 seconds

Performance Evaluation of a Two-Product CONWIP System with Poisson Demand Processes (Poisson 수요과정을 갖는 두 품목 콘윕시스템의 성능평가)

  • Park, Chan-Woo;Kim, Su-Min;Bang, Woo-Hyung;Lee, Hyo-Seong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.3
    • /
    • pp.172-182
    • /
    • 2013
  • In this study we consider a flow line CONWIP system in which two types of product are produced. The processing times of each product type at each station follow an independent exponential distribution and the demands for the finished products of each type arrive according to a Poisson process. The demands that are not satisfied instantaneously are either backordered or lost according to the number of unsatisfied demands that exist at their arrival instants. For this system we develop an approximation method to obtain the performance measures such as steady state probabilities of the number of parts of each product type at each station, mean waiting times of backordered demands and the proportion of backordered demands. For the analysis of the proposed CONWIP system, we model the CONWIP system as a two class closed queueing network with a synchronization station and analyze the closed queueing network using a product-form approximation method for multiple classes developed by Baynat and Dallery. In the approximation method, each subsystem is analyzed using a matrix geometric method. Comparisons with simulation show that the approximation method provides fairly good results for all performance measures.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

Analysis on Hypothetical Multiple Events of mSGTR and SBO at CANDU-6 Plants Using MARS-KS Code (중수로 원전 가상의 mSGTR과 SBO 다중 사건에 대한 MARS-KS 코드 분석)

  • Seon Oh YU;Kyung Won LEE;Kyung Lok BAEK;Manwoong KIM
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.18-27
    • /
    • 2021
  • This study aims to develop an improved evaluation technology for assessing CANDU-6 safety. For this purpose, the multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout (SBO) in a CANDU-6 plant was selected as a hypothetical event scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes logic models for controlling the pressure and inventory of the primary heat transport system (PHTS) decreasing due to the u-tubes' rupture, as well as the main features of PHTS with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was successfully achieved to confirm the stable convergence of the key parameters. Until the turbine trip, the fuel channels were adequately cooled by forced circulation of coolant and supply of main feedwater. However, due to the continuous reduction of PHTS pressure and inventory, the reactor and turbine were shut down and the thermal-hydraulic behaviors between intact and broken loops got asymmetric. Furthermore, as the conditions of low-flow coolant and high void fraction in the broken loop persisted, leading to degradation of decay heat removal, it was evaluated that the peak cladding temperature (PCT) exceeded the limit criteria for ensuring nuclear fuel integrity. This study is expected to provide the technical bases to the accident management strategy for transient conditions with multiple events.

Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF

Numerical Simulajtions of Non-ergodic Solute Transport in Strongly Heterogeneous Aquiferss (불균질도가 높은 대수층내에서의 비에르고딕 용질이동에 관한 수치 시뮬레이션)

  • Seo Byong-Min
    • The Journal of Engineering Geology
    • /
    • v.15 no.3
    • /
    • pp.245-255
    • /
    • 2005
  • Three dimensional Monte-Carlo simulations of non-ergodic transport of a non-reactive solute plume by steady-state groundwater flow under a uniform mean velocity in isotropic heterogeneous aquifers were conducted. The log-normally distributed hydraulic conductivity, K(x), is modeled as a random field. Significant efforts are made to reduce the simulation uncertainties. Ensemble averages of the second spatial moments of the plume, $$lt;S_{ij}'(t',l')$gt;$ and plume centroid variances, $$lt;R_{ij}'(t',l')$gt;$ were simulated with 3200 Monte Carlo runs for three variances of log K, $\omega^2_y1.0,,2.5,$ and 5.0, and three dimensionless lengths of line plume sources ( l=,5 and 10) normal to the mean velocity. The simulated second spatial moment and the plume centroid variance in longitudinal direction fit well to the first order theoretical results while the simulated transverse moments are not fit well with the first order results. The first order theoretical results definitely underestimated the simulated transverse second spatial moments for the aquifers of large u: and small initial plume sources. The ergodic condition for the second spatial moments is far from reaching, and the first order theoretical results of the transverse second spatial moment of the ergodic plume slightly underestimated the simulated moments.

Inhibition of L-type Ca2+ current by ginsenoside Rd in rat ventricular myocytes

  • Lu, Cheng;Sun, Zhijun;Wang, Line
    • Journal of Ginseng Research
    • /
    • v.39 no.2
    • /
    • pp.169-177
    • /
    • 2015
  • Background: Ginsenoside Rd (GSRd), one of the most abundant ingredients of Panax ginseng, protects the heart via multiple mechanisms including the inhibition of $Ca^{2+}$ influx.We intended to explore the effects of GSRd on L-type $Ca^{2+}$ current ($I_{Ca,L}$) and define the mechanism of the suppression of $I_{Ca,L}$ by GSRd. Methods: Perforated-patch recording and whole-cell voltage clamp techniques were applied in isolated rat ventricular myocytes. Results: (1) GSRd reduced $I_{Ca,L}$ peak amplitude in a concentration-dependent manner [half-maximal inhibitory concentration $(IC_{50})=32.4{\pm}7.1{\mu}mol/L$] and up-shifted the current-voltage (I-V) curve. (2) GSRd ($30{\mu}mol/L$) significantly changed the steady-state activation curve of $I_{Ca,L}$ ($V_{0.5}:-19.12{\pm}0.68$ vs. $-6.26{\pm}0.38mV$; n = 5, p < 0.05) and slowed down the recovery of $I_{Ca,L}$ from inactivation [the time content (${\zeta}$) from 91 ms to 136 ms, n = 5, p < 0.01]. (3) A more significant inhibitive effect of GSRd ($100{\mu}mol/L$) was identified in perforated-patch recording when compared with whole-cell recording [$65.7{\pm}3.2%$ (n = 10) vs. $31.4{\pm}5.2%$ (n = 5), p < 0.01]. (4) Pertussis toxin ($G_i$ protein inhibitor) completely abolished the $I_{Ca,L}$ inhibition induced by GSRd. There was a significant difference in inhibition potency between the two cyclic adenosine monophosphate elevating agents (isoprenaline and forskolin) prestimulation [$55{\pm}7.8%$ (n = 5) vs. $17.2{\pm}3.5%$ (n = 5), p < 0.01]. (5) 1H-[1,2,4]Oxadiazolo[4,3-a]-quinoxalin-1-one (a guanylate cyclase inhibitor) and N-acetyl-$\small{L}$-cysteine (a nitric oxide scavenger) partly recovered the $I_{Ca,L}$ inhibition induced by GSRd. (6) Phorbol-12-myristate-13-acetate (a protein kinase C activator) and GF109203X (a protein kinase C inhibitor) did not contribute to the inhibition of GSRd. Conclusion: These findings suggest that GSRd could inhibit $I_{Ca,L}$ through pertussis toxin-sensitive G protein ($G_i$) and a nitric oxide-cyclic guanosine monophosphate-dependent mechanism.

An Exploratory Study on Specialty Stores for Organic Foods

  • Lee, Young-Chul;Park, Chul-Ju;Lim, Su-Ji
    • Journal of Distribution Science
    • /
    • v.9 no.3
    • /
    • pp.47-54
    • /
    • 2011
  • This paper presents exploratory research on consumer awareness and attitudesabout organic food, for which consumer demand continues to increase the paper also assesses consumers' organic food distribution channel preferences. By conducting a literature review, a case study has been carried out in order to glean customer behavior, market condition and typesof distribution channels, and development of specialty stores for organic foods. The early research indicates that consumer awareness and customer attitudes toward organic food are mostly positive however, organic food's high price, as well as a lack of organic food stores, cause a negative effect on consumers' purchase intention. Secondly, the U.S. organic food retail channel consists of such mainstream supermarket/grocery stores and leading natural and organic food supermarket chains as Whole Foods, Trader Joe's, and Sunflower Farmers Market. For the current retail distribution of organic food in Korea, off-line stores are composed of direct management stores and franchise chains. Most of the organic food retail distribution operates through the Internet shopping mall, and are commonly located at retail distribution centers as multi-channel, shop-in-shop stores. Moreover, unlike in the U.S., association and consumers' cooperatives (Co-Ops), and such other member-direct retail stores as Hansallim, iCOOP, Nature Dream,and online shopping malls, are all active in Korea. Thirdly, as a result of an analysis of the present state of the organic food retail channel, as well as building a case for organic food specialty stores, the distinctive featuresand rapid growth of such unique organic food stores as Whole Foods Market, or Trader Joe's successful downsizing strategies, as well as Sunflower Farmers Market low-price approach, show steady industry growth. Moreover, as a result of a case studyof such domestic representative organic food specialty stores as "Olga" and "Chorokmaeul," a similar management style to the United States' "Whole Foods Market" and "Trader Joe's," respectively, can be seen. Similar to the U.S. market, Korean organic food markets should also implement active retail distribution opportunities, allowing consumers to select from various diverse and differentiated choices. In order to accomplish this goal, it is necessary to prepare such measures as sustaining reasonable prices, securing various suppliers for unique products,and improving consumer trust through advertisement strategies that are suitable for each company's branding processes.

  • PDF

Hepatitis B Virus-Induced TNF-a Expression in Hepa-lc1c7 Mouse Hepatoma Cell Line (마우스 Hepa-1c1c7 세포주에서 B형 간염 바이러스에 의한 tumor necrosis factor-a의 발현 유도)

  • Yea Sung Su;Jang Won Hee;Yang Young-Il;Lee Youn Jae;Kim Mi Seong;Seog Dae-Hyun;Park Yeong-Hong;Paik Kye-Hyung
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.38-44
    • /
    • 2005
  • Infection with hepatitis B virus (HBV) is a major health problem worldwide. Although a tremendous amount has been known about HBV, there have been obstacles in the study of HBV due to the narrow host range of HBV limited to humans and primates. In the present study, we investigated the susceptibility to HBV infection of mouse hepatoma cell line, Hepa-1c1c7. In addition, based on that human hepatocytes infected by HBV increase the expression of the pro-inflammatory cytokine TNF-a, the inducibility of TNF-a expression by HBV in the cells was determined. HBV surface antigen (HBsAg) secretion was measured by the microparticle enzyme immunoassay and steady state mRNA expression was analyzed by quantitative competitive RT-PCR. Transient transfection of Hepa-1c1c7 cells with HBV expression vector resulted in a dose-dependent induction of TNF-a expression. Infection of Hepa-1c1c7 cells with the serum of HBV carrier also increased TNF-a mRNA expression. Both in the transfected and infected cells, HBV mRNA was expressed and significant HBsAg secretion was detected. There was no significant variation in $\beta-actin$ mRNA expression by HBV. These results demonstrate that HBV is infectious to Hepa-lc1c7 in vitro and the viral infection induces TNF-a expression, which suggests that Hepa-lc1c7, a mouse hepatoma cell line, may be a possible model system for analysis of various molecular aspects of HBV infection.

Monte-Carlo Simulations of Non-ergodic Solute Transport from Line Sources in Isotropic Mildly Heterogeneous Aquifers (불균질 등방 대수층 내 선형오염원으로부터 기원된 비에르고딕 용질 이동에 관한 몬테카를로 시뮬레이션)

  • Seo Byong-min
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.20-31
    • /
    • 2005
  • Three dimensional Monte-Carlo simulations of non-ergodic transport of a lion-reactive solute plume by steady-state groundwater flow under a uniform mean velocity in isotropic heterogeneous aquifers were conducted. The log-normally distributed hydraulic conductivity, K(x), is modeled as a random field. Significant efforts are made to reduce tile simulation uncertainties. Ensemble averages of the second spatial moments of the plume and plume centroid variances were simulated with 1600 Monte Carlo runs for three variances of log K, ${\sigma}_Y^2=0.09,\;0.23$, and 0.46, and three dimensionless lengths of line plume sources normal to the mean velocity. The simulated second spatial moment and the plume centroid variance in longitudinal direction fit well to the first order theoretical results while the simulated transverse moments are generally larger than the first order results. The first order theoretical results significantly underestimated the simulated dimensionless transverse moments for the aquifers of large ${\sigma}_Y^2$ and large dimensionless time. The ergodic condition for the second spatial moments is far from reaching in all cases simulated, and transport In transverse directions may reach ergodic condition much slower than that in longitudinal direction. The evolution of the contaminant transported in a heterogeneous aquifer is not affected by the shape of the initial plume but affected mainly by the degree of the heterogeneity and the size of the initial plume.