• Title/Summary/Keyword: Steady State Performance

Search Result 1,426, Processing Time 0.03 seconds

A Hydration based Model for Chloride Penetration into Slag blended High Performance Concrete

  • Shin, Ki-Su;Park, Ki-Bong;Wang, Xiao-Yong
    • Architectural research
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • To improve the chloride ingress resistance of concrete, slag is widely used as a mineral admixture in concrete industry. And currently, most of experimental investigations about non steady state diffusion tests of chloride penetration are started after four weeks standard curing of concrete. For slag blended concrete, during submerged chloride penetration tests periods, binder reaction proceeds continuously, and chloride diffusivity decreases. However, so far the dependence of chloride ingress on curing ages are not detailed considered. To address this disadvantage, this paper shows a numerical procedure to analyze simultaneously binder hydration reactions and chloride ion penetration process. First, using a slag blended cement hydration model, degree of reactions of binders, combined water, and capillary porosity of hardening blended concrete are determined. Second, the dependences of chloride diffusivity on capillary porosity of slag blended concrete are clarified. Third, by considering time dependent chloride diffusivity and surface chloride content, chloride penetration profiles in hardening concrete are calculated. The proposed prediction model is verified through chloride immersion penetration test results of concrete with different water to binder ratios and slag contents.

A numerical analysis of forced convection heat transfer in an electric oven (전기오븐의 강제대류 열전달 특성 연구)

  • Noh, Sun-Jong;Cho, Seong-Ho;Kim, Hyeong-Sik;Kwag, Dong-Seong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.124-128
    • /
    • 2011
  • The heat transfer rate in an oven is very important for the quality of cooking food. For a robust performance design in an electric oven, forced convection has been used rather than natural convection, in bake and convection mode. Forced convection heat trans for in a vented electric oven has been numerically evaluated using the commercial software FLUENT. CFD modeling of the electric oven involves three-dimensional, steady state, MRF fan model and DO radiation model. In this study, the electric oven cavity and fan modules are not simplified. Other research shows that the boundary condition can often lead to non-physical solutions, such as reverse flaw at the top vent. To remove this non-physical solution, control volume has been expanded at the nearby vent. This numerical analysis has been performed with dedicated experimental support. The results show that there is less than a 2.2% difference between the simulation and experimental data for the temperature profile of food. From this research we can use this oven simulation technique to make a better convection system in an electric oven.

  • PDF

A STUDY ON IMPLICIT METHOD FOR SOLVING INCOMPRESSIBLE FLOW WITH UNSTRUCTURED MESHES (비정렬 격자상에서 비압축성 유동해석을 위한 음해법에 대한 연구)

  • Kim, M.G.;Ahn, H.T.
    • Journal of computational fluids engineering
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • A new and efficient implicit scheme is proposed to obtain a steady-state solution in time integration and the comparison of characteristics with the approximation ways for the implicit method to solve the incompressible Navier-Stokes equations is provided. The conservative, finite-volume cell-vertex upwind scheme and artificial compressibility method using dual time stepping for time accuracy is applied in this paper. The numerical results obtained indicate that the direct application of Jacobian matrix to the Lower and upper sweeps of implicit LU-SGS leads to better performance as well as convergence regardless of CFL number and true time step than explicit scheme and approximation of Jacobian matrix. The flow simulation around box in uniform flow with unstructured meshes is demonstrated to check the validity of the current formulation.

A Variable Modulus Algorithm using Sigmoid Nonlinearity with Variable Variance (가변 분산을 갖는 시그모이드 비선형성을 이용한 가변 모듈러스 알고리즘)

  • Kim Chul-Min;Choi Ik-Hyun;Oh Kil-Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.649-653
    • /
    • 2005
  • To estimate for an error signal with sigmoid nonlinearity what reduced constellation applies closed eye pattern in the initial equalization, there can be improves problems of previous soft decision-directed algorithm that increasing estimate complexity and decreasing of convergence speed when substitute high-order constellation. The characteristic of sigmoid function is adjusted by a mean and a variance parameter, so it depends on adjustment of variance that what reduced constellation $values(\gamma)$ can have ranges between + $\gamma$ and - $\gamma$. In this paper, we proposed Variable Modulus Algorithm (VMA) that can be improving a performance of steady-state by adjustment of variance when equalization works normally and each cluster of constellation decrease.

  • PDF

Fault Diagnosis of Induction Motor using Linear Predictive Coding and Deep Neural Network (LPC와 DNN을 결합한 유도전동기 고장진단)

  • Ryu, Jin Won;Park, Min Su;Kim, Nam Kyu;Chong, Ui Pil;Lee, Jung Chul
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.11
    • /
    • pp.1811-1819
    • /
    • 2017
  • As the induction motor is the core production equipment of the industry, it is necessary to construct a fault prediction and diagnosis system through continuous monitoring. Many researches have been conducted on motor fault diagnosis algorithm based on signal processing techniques using Fourier transform, neural networks, and fuzzy inference techniques. In this paper, we propose a fault diagnosis method of induction motor using LPC and DNN. To evaluate the performance of the proposed method, the fault diagnosis was carried out using the vibration data of the induction motor in steady state and simulated various fault conditions. Experimental results show that the learning time of our proposed method and the conventional spectrum+DNN method is 139 seconds and 974 seconds each executed on the experimental PC, and our method reduces execution time by 1/8 compared with conventional method. And the success rate of the proposed method is 98.08%, which is similar to 99.54% of the conventional method.

A Modified Switched-Diode Topology for Cascaded Multilevel Inverters

  • Karasani, Raghavendra Reddy;Borghate, Vijay B.;Meshram, Prafullachandra M.;Suryawanshi, H.M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1706-1715
    • /
    • 2016
  • In this paper, a single phase modified switched-diode topology for both symmetrical and asymmetrical cascaded multilevel inverters is presented. It consists of a Modified Switched-Diode Unit (MSDU) and a Twin Source Two Switch Unit (TSTSU) to produce distinct positive voltage levels according to the operating modes. An additional H-bridge synthesizes a voltage waveform, where the voltage levels of either polarity have less Total Harmonic Distortion (THD). Higher-level inverters can be built by cascading MSDUs. A comparative analysis is done with other topologies. The proposed topology results in reductions in the number of power switches, losses, installation area, voltage stress and converter cost. The Nearest Level Control (NLC) technique is employed to generate the gating signals for the power switches. To verify the performance of the proposed structure, simulation results are carried out by a PSIM under both steady state and dynamic conditions. Experimental results are presented to validate the simulation results.

A Novel High Step-Up Converter with a Switched-Coupled-Inductor-Capacitor Structure for Sustainable Energy Systems

  • Liu, Hongchen;Ai, Jian;Li, Fei
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.436-446
    • /
    • 2016
  • A novel step-up DC-DC converter with a switched-coupled-inductor-capacitor (SCIC) which successfully integrates three-winding coupled inductors and switched-capacitor techniques is proposed in this paper. The primary side of the coupled inductors for the SCIC is charged by the input source, and the capacitors are charged in parallel and discharged in series by the secondary windings of the coupled inductor to achieve a high step-up voltage gain with an appropriate duty ratio. In addition, the passive lossless clamped circuits recycle the leakage energy and reduce the voltage stress on the main switch effectively, and the reverse-recovery problem of the diodes is alleviated by the leakage inductor. Thus, the efficiency can be improved. The operating principle and steady-state analyses of the converter are discussed in detail. Finally, a prototype circuit at a 50 kHz switching frequency with a 20-V input voltage, a 200-V output voltage, and a 200-W output power is built in the laboratory to verify the performance of the proposed converter.

Blind Adaptive Equalizer Using the Improved Radius-Directed Algothm (개선된 반경-지향 방식을 이용한 블라인드 적응 등화기)

  • 윤영우;이영조;조형래;홍대식;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1364-1373
    • /
    • 1994
  • In this thesis, an algorithm for fast convergence to the steady state and for achieving an improved MSE in blind adaptive equalizers is proposed. The conventional radius-directed algorithm can be transformed into an algorithm that provides effective blind convergence in the aspect of the MSE as the convergence speed. This can be achieved through altering the stop and go algorithm. The performance of the new algorithm is analyzed and compared with the two conventional algorithms, such as the CMA and the stop and go algorithm. The experimental results show the superiority of the new algorithm.

  • PDF

Direct Single-stage Power Converter with Power Factor Improvement for Switched Mode Power Supply

  • Kalpana, R.;Singh, Bhim;Bhuvaneswari, G.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.468-476
    • /
    • 2010
  • This paper presents a direct single-stage power converter using single-phase isolated full-bridge converter modules, with inherent power factor correction (PFC) for a 12 kW switched mode power supply (SMPS). The advantages of the proposed converter are its simple control strategy, reduction in number of conversion stage, low input line current harmonics, and improvement in power factor. Analysis of the single-stage converter is carried out in continuous conduction mode of operation. Steady-state analysis of the proposed converter is conducted to obtain converter parameters. A systematic design procedure is also presented for a 12k W converter with a design example. The effect of load variation on SMPS is also studied in order to demonstrate the effectiveness of the proposed converter for the complete range of load conditions. A set of power quality indices on input ac mains for an SMPS fed from a single-stage converter is also presented for easy comparison of their performance.

Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torches

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.591-598
    • /
    • 2011
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torches. A series resonant half-bridge topology is presented as a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. A plasma torch rated at 3MW, 2kA and having a physical size of 1m is selected to be the high enthalpy source for a waste disposal system. The steady-state and transient operations of a plasma torch are simulated. The parameters of a Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. The circuit simulation waveform shows that the ripple of the arc current can be maintained within ${\pm}10%$ of its rated value under the presence of a load disturbance. This power conversion configuration provides a high enough ignition voltage, around 5KA, during the ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.