• Title/Summary/Keyword: Steady State Performance

Search Result 1,426, Processing Time 0.033 seconds

Study on the performance improvement of a Main Oxidizer shut-off Valve Using Computer Aided Structural Analysis (전산 구조해석을 이용한 산화제 개폐밸브 성능향상에 관한 연구)

  • Kim, Do-Hyung;Bae, Young-Woo;Hong, Moon-Geun;Yoo, Jae-Han;Kim, Eun-Soo;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.111-114
    • /
    • 2010
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the steady operational state. To modify the middle flange and rip of inlet valve design by Computer Aided Structural Analysis for improvement of EM core functions. In result, it has been verified to improve performance of EM by tests.

  • PDF

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • v.6 no.1
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

Performance of the Cooling and Heating of Heat Pump Using Non-azeotropic Refrigerant Mixtures (비공비혼합냉매를 이용한 열펌프의 냉난방성능에 관한 연구)

  • 박기원;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.53-61
    • /
    • 1994
  • An experimental study on heat pump cycle systematizing characteristics for non-azeotropic refrigerant mixtures of R-22+R-114 was reported. Data were obtained under steady state condition at the ranges of parameters, 550- 2, 170kcal/h, 670-2, 990kcal/h, 24-71kg/h, and 0-1, for as cooling capacity, heating capacity, mass 25, 50, 75, and 100 per cent of R-22 by weight fraction for R-22+R-114 mixtures. The results shown that the C.O.P of the 50wt% of R-22 mixture was considerably larger than for pure R-22 and other weight fraction of R-22 mixtures, but the compression power of the 25wt% of R-22 was lower than that of the pure R-22 and the other weight fraction of R-22 mixtures. The hightest value of cooling capacity was obtained at the conditions of evaporating temperature 5.deg.C and R-22 50wt% mixture. In general, with an increase in the R-22 weight fraction for fixed values of the other parameter, the cooling capacity increased at first, obtained a maximum, and then decreasd. This verified the importance of accurate weight fractions od refrigerant mixtures in the heat pump cycle.

  • PDF

Random Access Channel with Retransmission Gain

  • Shi, Junmin;Sun, Yi;Zhang, Xiaochen;Xiao, Jizhong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.3
    • /
    • pp.148-159
    • /
    • 2013
  • An analysis of the throughput and stability region of random access systems is currently of interest in research and industry. This study evaluated the performance of a multiuser random access channel with a retransmission gain. The channel was composed of a media access control (MAC) determined by the transmission probabilities and a multiuser communication channel characterized by the packet reception probabilities as functions of the number of packet transmissions and the collision status. The analysis began with an illustrative two-user channel, and was extended to a general multiuser channel. For the two-user channel, a sufficient condition was derived, under which the maximum throughput was achieved with a control-free MAC. For the channel with retransmission gain, the maximum steady throughput was obtained in a closed form. The condition under which the random access channel can acquire retransmission gain was also obtained. The stability region of the general random access channel was derived. These results include those of the well-known orthogonal channel, collision channel and slotted Aloha channel with packet reception as a special instance. The analytical and numerical results showed that exploiting the retransmission gain can increase the throughput significantly and expand the stability region of the random access channel. The analytical results predicted the performance in the simulations quite well.

  • PDF

Analysis of Heat Loss Due to Time Dependent Aging of Insulation Applied to Office Building (업무용 건축물에 적용된 단열재의 경년열화에 따른 열손실량 분석)

  • Lee, Do-Hyung;Nah, Hwan-Seon
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.5
    • /
    • pp.65-75
    • /
    • 2017
  • In this study, the change of heat loss due to the degree of deterioration of the XPS insulation in KEPCO's office buildings is analyzed. The acceleration aging test of the XPS insulation was carried out according to the test method A of KS M ISO 11561: 2009. The performance of the insulation was analyzed by applying it to the three - dimensional steady state heat transfer analysis program. The acceleration aging test of the XPS insulation, show that the thermal resistance performance decreased by 1.44% at the A regional headquarters, 0.85% at the B regional headquarters, 6.41% at the C branch office, 7.76% at the D regional headquarters, 8.51% at the E branch office, and by 8.54% at the F branch office respectively. Using simulation, we determined that the thermal resistance value of E branch office decreased by 8.04%, while its heat loss increased by 8.52%. At A regional headquarters, the thermal resistance decreased by 1.38%, and the heat loss increased by 1.51%. At D regional headquarters, these value are 6.82% and 7.17%, respectively.

STUDY ON THE OPTIMAL DESIGN OF A VEHICLE INTAKE SYSTEM USING THE BOOMING NOISE AND THE SOUND QUALITY EVALUATION INDEX

  • LEE J. K.;PARK Y. W.;CHAI J. B.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, an index for the evaluation of a vehicle intake booming noise and intake sound quality were developed through a correlation analysis and a multiple factor regression analysis of objective measurement and subjective evaluation data. At first, an intake orifice noise was measured at the wide-open throttle test condition. And then, an acoustic transfer function between intake orifice noise and interior noise at the steady state condition was estimated. Simultaneously, subjective evaluation was carried out with a 10-scale score by 8 intake noise and vibration expert evaluators. Next, the correlation analysis between the psychoacoustic parameters derived from the measured data and the subjective evaluation was performed. The most critical factor was determined and the corresponding index for intake booming noise and sound quality are obtained from the multiple factor regression method. And, the optimal design of intake system was studied using the booming noise and the sound quality evaluation index for expectation performance of intake system. Conclusively, the optimal designing parameters of intake system from noise level and sound quality whose point of view were extracted by adapting comparative weighting between the booming noise and sound quality evaluation index, which optimized the process. These work could be represented guideline to system engineers, designers and test engineers about optimization procedure of system performance by considering both of noise level and sound quality.

Performance Analysis of an Integrated Voice/Data Packet Communication Network with Window Flow Control (Window Flow 제어기능을 가진 음성/데이타 패킷통신망의 성능해석)

  • 손수현;은종관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.4
    • /
    • pp.227-236
    • /
    • 1986
  • In this paper, an integrated voice/data packet network with window flow control is modeled by a colsed multichain queueing system, and its performance is analyzed by the mean value analysis method. Particularly, for the analysis of a packet network having various kinds of messages with different priority classes, we introduce an approach based on the mean value analysis and the concept of effective capacity. By the mathematical analysis and computer simulation, we obtain the following network statistics in the steady state: Mean buffer occupancy at each node, utilization of link throughput of a virtual channel, and mean delay time of each message. Our iterative analysis method can predict the link data status in most cases within about 10 percent of accurady, and the statistics of voice messages and external data within 5 percent as compared to simulation results.

  • PDF

New Fuzzy Controller for High Performance of Induction Motor Drive (유도전동기 드라이브의 고성능 제어를 위한 새로운 퍼지제어기)

  • Chung, Dong-Hwa;Lee, Jung-Chul;Lee, Hong-Gyun
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.87-93
    • /
    • 2002
  • This paper is presented new fuzzy controller for high performance of induction motor drive. New fuzzy controller took out appropriate amounts of accumulated control input according to fuzzy described situations in addition to the incremental control input calculated by conventional direct fuzzy controller. The structures of the proposed controller was motivated by the problems of direct fuzzy controller. The direct controller was given generally inevitable overshoot when one tries to reduce rise time of response. The undesirable characteristics of the direct fuzzy controller are caused by integrating operation of the controller, even though the integrator itself is introduced to overcome steady state error in provide a thorough comparative insight into the behavior of induction motor drive with direct and new fuzzy speed controller. The validity of the comparative results is confirmed by the simulation results for induction motor drive system.

Design and control of Single Loop Output Voltage Controller for 3 Phase PWM Inverter (3상 PWM 인버터의 단일제어루프 전압제어기의 설계 및 제어)

  • Gang B.H.;Gho J.S.;Cho J.S.;Choe G.H.;Kwak C.H.;Kim J.H,
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.496-500
    • /
    • 2001
  • There are two ways in the output voltage control method in PWM inverter. One is the double loop voltage control composed of inner current control loop and outer voltage control loop. Because it shows fast response and low steady state error, utilized in many application. The Other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. But in low output impedance, it shows good control performance in all load range than double loop control. In this paper, single loop voltage control rule and gain was developed analytically, and these were verified through computer simulation and experiment.

  • PDF

A Criterion for Interaction Analysis and Loop Pairing Among Control System Variables (제어 시스템 변수들간의 상호작용 해석 및 루프 페어링을 위한 판별기준)

  • Ko Jae Wook;Yoon En Sup;Evans L. B.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.64-74
    • /
    • 1999
  • Using the steady state gains, an appropriate criterion used for the interaction analysis among variables and the loop pairing is suggested. Based upon the suggested criterion derived from the derivative relation of implicit function, the SISO pairing which has minimum interaction among control system variables and good control performance can be determined. The relative effect among diagonal gains and off-diagona gains, which was not considered in other criteria, can be explained deterministically Also, the criterion can be easily applied to partial MIMO pairing. This criterion was applied to several examples to illustrate its usefulness in finding the feasible SISO pairing and MIMO pairing

  • PDF