• 제목/요약/키워드: Stator current

검색결과 683건 처리시간 0.021초

마이크로 프로세서에 의한 영구자석 동기 전동기의 자기제어기(自己制御器) 설계 및 구동 (Microprocessor - based Self - controllers for the drive of Permanent Magnet Synchronous Motors -)

  • 윤병도;김윤호;이용석;김일환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.283-287
    • /
    • 1989
  • This paper presents a microprocesser based Self-Controller for a Permanent Magnet Synchronous Motor(PMSM), fed by voltage soure inverter. The proper operation of the PMSM can be ensured only if the stator current is always synchronized with the its Back-E.M.F. The use of incremantal encoder with high resolution makes it possible to design a Self-Control led P.W.M. inverter. The pulse ratios are controlled to reduce the torque ripple in the low-speed drive region. And during the operation, torque - speed characteristics are improved by the control of optimal load angle.

  • PDF

Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Flux-Weakening Control

  • Kim, Jan-Mok;Rhew, Hong-Woo;Kwon, Jung-Lock;Sul, Seung-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.103-109
    • /
    • 1998
  • A new flux-weakening scheme for an Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This control scheme enables the maximum torque operation for the fast acceleration in the constant power region according to the current and voltage limit condition. Especially the dynamic performance of the braking in the flux-weakening region is improved with the compensation of the stator resistance. Also since the onset of the flux weakening operation is adjusted according to the load conditions, the machine parameters, and whether motoring or braking region, the stable and precise transition operation into or out of the flux weakening region can be achieved. The effectiveness of the proposed scheme is verified through experiments with an IPMSM drive system.

  • PDF

Thermal Analysis of a Canned Induction Motor for Main Coolant Pump in System-Integrated Modular Advanced Reactor

  • Huh, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.32-36
    • /
    • 2003
  • The three-phase canned induction motor, which consists of a stator and rotor with a seal can, is used for the main coolant pump (MCP) of the System-integrated Modular Advanced Reactor (SMART). The thermal characteristics of the can must be estimated exactly, since the eddy current loss of the can is a dominant parameter in design. Besides the insulation of the motor winding is compared of Teflon, glass fiber, and air, so it is not an easy task to analyze. A FEM thermal analysis was per-formed by using the thermal properties of complex insulation which were obtained by comparing the results of finite element thermal analysis and those of the experiment. As a result, it is shown that the characteristics of prototype canned induction motor have a good agreement with the results of FEM.

축전기형 전동기의 토크에 대한 특성분석 및 그 변동성분의 감소를 위한 연구 (Identification of Torque Characteristics in Capacitor Type Electric Motors and Reduction of Its Fluctuation Components)

  • 고홍석;신성수;김광준
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.826-834
    • /
    • 1994
  • The purpose of this study is to identify torque characteristics in capacitor type electric motors and to illustrate the effects of several design parameters on the fluctuating components of the motor torque. To do this, two revolving field theory and stationary reference frame theory were applied to derive governing equations for the torque generated by motor. For simulation studies, parameters of the motor components were measured under the conditions of no loading and locking. Based on these, effects of several design variables on the torque characteristics were analyzed and compared with the actual measurements, which were estimated indirectly by measuring the stator voltage and current. Then, some illustrative improvements in design are suggested by taking Taguchi method.

DTW를 이용한 유도전동기 베어링 및 회전자봉 고장진단 (Fault Detection and Diagnosis of Faulty Bearing and Broken Rotor Bar of Induction Motors Based on Dynamic Time Warping)

  • 이재현;배현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.95-102
    • /
    • 2007
  • The issues of preventive and condition-based maintenance, online monitoring, system fault detection, diagnosis and prognosis are of increasing importance. This study introduces a technique to detect and identify faults in induction motors. Stator currents were measured and stored by time domain. The time domain is not suitable for representing current signals, so wavelet transform is used to convert the signals onto frequency domain. The raw signals can not show the significant feature, therefore difference values between the signal of the health conditions and that of the fault conditions are applied. The difference values were transformed by wavelet transform and the features are extracted from the transformed signals. The dynamic time warping method was used to identify the fault type. This study describes the results of detecting fault using wavelet analysis.

단순 원판형 평면 3자유도 액추에이터 설계 (Design of A Simple Disk-type 3-DOF Actuator)

  • 백두진;김하용;김승종
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.334-340
    • /
    • 2005
  • A disk-type 3-DOF actuator which has new principle and very simple structure is proposed. Also it utilizes the relation of bias and control fluxes produced by permanent magnets and coils, respectively, like other conventional electromagnetic actuators, but its main feature is that both the coils and permanent magnets are fixed in the stator, which makes it easy to design the shape of moving part. Operating principle is that a moving disk is driven by reaction force of Lorentz force acting on the fixed equivalent coil. Simple analytic approach and FEM analysis are performed to determine the design parameters so as to increase the driving force and distance. And some experimental results show the feasibility of the proposed actuator.

Winding Turn-to-Turn Faults Detection of Fault-Tolerant Permanent-Magnet Machines Based on a New Parametric Model

  • Liu, Guohai;Tang, Wei;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.23-30
    • /
    • 2013
  • This paper proposes a parametric model for inter-turn fault detection in a fault-tolerant permanent-magnet (FTPM) machine, which can predict the effect of the short-circuit fault to various physical quantity of the machine. For different faulty operations, a new effective stator inter-turn fault detection method is proposed. Finally, simulations of vector-controlled FTPM machine drives are given to verify the feasibility of the proposed method, showing that even single-coil short-circuit fault could be exactly detected.

2자유도 제어기를 이용한 철도차량시스템의 실시간 토크제어 (On-line Torque Control of Railway Vehicle System that Use 2DOF Controller)

  • 김은기;김철호;정은성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.196-203
    • /
    • 2010
  • 2DOF is applied to induction moor in order to supply these weak points of PI torque control method in this paper. and The proposed method utilize the combination of the voltage model based on stator equivalent model and the current model based on rotor equivalent model, which enables stable estimation of rotor flux. To prove the propriety of this paper, the various simulations carried out adequacy and stability using Matlab, and at the same time real system is made, so it is proved. As the results of embodying the system, the robust system is realized.

  • PDF

회전 기기의 수명 예측 평가에 관한 연구 (A Study on the Expected Life Evaluation of Rotating Machine)

  • 김기준;김상진;오용철;성낙진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.73-76
    • /
    • 2000
  • Traction motors that is one of the rotating machines for urban transit EMU have been subjected to increased demand for higher operating temperature, more demanding duty cycles, higher starting current, frequent voltage transients and severe environmental exposure. With the advent of PWM drives using power IGBTs in addition to the thermal considerations, it is important to take into account the impact of the dielectric stress upon the winding insulation system life. In analyzing the life of the stator winding, which is the heart of the motor, the majority of all winding failures are usually caused by a combination of various stresses acting on the insulation materials and system. In this paper, to evaluate the expected life of traction motor for urban transit E.M.U. it is proposed a new test method of complex accelerating degradation.

  • PDF

BLDC 전동기의 자계분포 Part II : 전기자 반작용 자계 (Magnetic Field Distribution in Brushless Permanent Magnet do Motors, Part II : Armature-Reaction Field)

  • 장석명;최장영;조한욱;양현섭;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.37-39
    • /
    • 2004
  • This paper deals with the prediction of armature reaction field produced by 3-phase stator windings whose current waveform contains significant harmonics. On the basis of 2-d analytical technics, we derived governing equation and predicted magnetic field distribution according to rotor position. The results of predictions from the analysis are compared with corresponding FE (finite element) analyses.

  • PDF