• Title/Summary/Keyword: Statistic Technique

Search Result 121, Processing Time 0.027 seconds

Studies on the Optical and the Electrical Characterization of Organic Electroluminescence Devices of Europium Complex Fabricated with PVD(Physical Vopor Deposition) Technique (진공 증착법에 의하여 제작한 Europium complex 유기 박막 전기발광소자의 광학적.전기적 특성에 관한 연구.)

  • Lee, Myeong-Ho;Lee, Han-Seong;Kim, Yeong-Gwan;Kim, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.285-295
    • /
    • 1999
  • Electroluminescent(EL) devices based on organic materials have been of great interest due to their possible applications for large-area flat-panel displays. They are attractive because of their capability of multi-color emission, and low operation voltage. An approach to realize such device characteristics is to use active layers of lanthanide complexes with their inherent extremely sharp emission bands in stead of commonly known organic dyes. In general, organic molecular compounds show emission due to their $\pi$-$\pi*$ transitions resulting in luminescence bandwidths of about 80 to 100nm. Spin statistic estimations lead to an internal quantum efficiency of dye-based EL devices limited to 25%. On the contrary, the fluorescence of lanthanide complexes is based on an intramolecular energy transfer from the triplet of the organic ligand to the 4f energy states of the ion. Therefore, theoretical internal quantum efficiency is principally not limited. In this study, Powders of TPD, $Eu(TTA)_3(phen) and AlQ_3$ in a boat were subsequently heated to their sublimation temperatures to obtain the growth rates of 0.2~0.3nm/s. Organic electrolumnescent devices(OELD) with a structure of $glass substrate/ITO/Eu(TTA)_3(phen)/AI, glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AI and glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AIQ_3AI$ structures were fabricated by vacuum evaporation method, where aromatic diamine(TPD) was used as a hole transporting material, $Eu(TTA)_3(phen)$ as an emitting material, and Tris(8-hydroxyquinoline)Aluminum$(AlQ_3)$ as an electron transporting layer. Electroluminescent(EL) and current density-voltage(J-V) characteristics of these OELDs with various thickness of $Eu(TTA)_3(phen)$ layer were investigated. The triple-layer structure devices show the red EL spectrum at the wavelength of 613nm, which is almost the same as the photoluminescent(PL) spectrum of $Eu(TTA)_3(phen)$.It was found from the J-V characteristics of these devices that the current density is not dependent on the applied field, but on the electric field.

  • PDF

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

Study on the Selection of the Basin Characteristics Parameters in River Basin Using Satellite Images and GIS (위성영상(衛星映像)과 GIS를 이용한 하천유역(河川流域)의 유역특성인자(流域特性因子) 추출(抽出)추출 관한 연구(硏究))

  • Jo, Myung-Hee;Ahn, Seung-Seop
    • Journal of the Korean association of regional geographers
    • /
    • v.4 no.1
    • /
    • pp.121-134
    • /
    • 1998
  • In this study, the satellite images and the GIS technique are used to select the basin characteristics parameters as the basis of water resources management of river basin. The study area is Geum-ho river basin and the hydrologic characteristics data are computed through the database of the basin characteristics parameters classified by subjects with 35 maps correspond to the study basin of 1:25,000 scale as the basic map. As the result, the drawing up of land use map through satellite image processing that provides the quantitative informations for the land is very efficient to analysis the extensive land use information of the basin, and exact analysis of mass surface data is possible and the feasibility of statistic computation between spatial subjects as it superpose on other subject map is ascertained. It is thought also that the analysis of the basin characteristics data can be utilized very effectively for the basin management and the analysis of basin surface area, once it is expressed numerically for database, since the superposition analysis with different subject map and the correlative analysis with the property data are possible although the tracing process of each subject in the basic map is not efficient. Especially, modification and renewal of the data for the change of land surface become easy, therefore more rapid and exact selection of the basin characteristics data and the construction of more efficient basin management plan are possible.

  • PDF

GIS-based Spatial Integration and Statistical Analysis using Multiple Geoscience Data Sets : A Case Study for Mineral Potential Mapping (다중 지구과학자료를 이용한 GIS 기반 공간통합과 통계량 분석 : 광물 부존 예상도 작성을 위한 사례 연구)

  • 이기원;박노욱;권병두;지광훈
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.2
    • /
    • pp.91-105
    • /
    • 1999
  • Spatial data integration using multiple geo-based data sets has been regarded as one of the primary GIS application issues. As for this issue, several integration schemes have been developed as the perspectives of mathematical geology or geo-mathematics. However, research-based approaches for statistical/quantitative assessments between integrated layer and input layers are not fully considered yet. Related to this niche point, in this study, spatial data integration using multiple geoscientific data sets by known integration algorithms was primarily performed. For spatial integration by using raster-based GIS functionality, geological, geochemical, geophysical data sets, DEM-driven data sets and remotely sensed imagery data sets from the Ogdong area were utilized for geological thematic mapping related by mineral potential mapping. In addition, statistical/quantitative information extraction with respective to relationships among used data sets and/or between each data set and integrated layer was carried out, with the scope of multiple data fusion and schematic statistical assessment methodology. As for the spatial integration scheme, certainty factor (CF) estimation and principal component analysis (PCA) were applied. However, this study was not aimed at direct comparison of both methodologies; whereas, for the statistical/quantitative assessment between integrated layer and input layers, some statistical methodologies based on contingency table were focused. Especially, for the bias reduction, jackknife technique was also applied in PCA-based spatial integration. Through the statistic analyses with respect to the integration information in this case study, new information for relationships of integrated layer and input layers was extracted. In addition, influence effects of input data sets with respect to integrated layer were assessed. This kind of approach provides a decision-making information in the viewpoint of GIS and is also exploratory data analysis in conjunction with GIS and geoscientific application, especially handing spatial integration or data fusion with complex variable data sets.

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

A Case Study(II) on Development and Application of 'Literature-Art-Science' Integrated Education Programs ('문학-미술-과학' 융합교육 프로그램의 개발 및 적용 사례 연구(II))

  • Choi, Byung Kil
    • Korea Science and Art Forum
    • /
    • v.32
    • /
    • pp.319-334
    • /
    • 2018
  • This research is a case study to make sure the enhancement of students' imagination and creativity through developing and applying the Literature-Art-Science Integrated Education Program. Its research object was totally 25 persons of 29 students of the 1st to the 4 th Grades from Gunsan Sulsan Elementary School. Its research period lasted for 4 months from September to December, 2017, and I, as the research place, used the art room at Gunsan Sulsan Elementary School. The programs were totally 10 sessions with a unit of 1 session per each grade for 2 hours from 1:00 to 3:00 in the afternoon from Monday through Friday. I fixed ten themes of this program-eight plane modeling, and two solid modeling, and finished the work of storytelling during summer vacation. And I arranged their levels as low:middle:high(3:5:2) ones. The former was 'A Film of Monster Gorilla'(L), 'Learning the Spirit of Gyeongju Choi's Family'(M), 'A Tale of My Friend Made of Natural Materials'(L), 'The Reading of My Dream'(M), 'Gathering the Objects in My Mobile'(M), 'A Mock Trial of Marrying Off'(M), 'Painting My Favorite Children's Poem'(H), and 'Painting My Favorite Children's Song'(H), and the latter was 'Seeking for a Bluebird in My Mind'(L), and 'Making My Cherished Object' (M). Then I used the unique art expression technique per each theme, which were in sequence marbling, Korean paper art, combine painting, collage, imaginary painting, imaginary painting, play dough art, imaginary painting techniques. And I delivered to the students the scientific knowledge in terms of growing or manufacturing processes of materials used for making artworks. Prior to and after the processing this program, I surveyed about the students' ability of integrated thinking and emotional experience by 'Figure B Type' and 'Figure A Type' of The Torrance Tests of Creative Thinking, and took statistics with the resultant data. And I executed a paired t-test in order to verify the significance of mean difference in the result of investigation with those data. From the analyzed result according to the elements of creativity and the mean quotients of creativity, there showed a significant difference (t=3.47, p<.01) in 'fluency', and also a significant difference(t=3.59, p<.01) in 'creativity.' Judging from the statistic values of two fields such as the student's ability of integrated thinking and emotional experience, I estimate that over the majority of the students showed the enhancement in self-confident creative expression as well as higher interest and concern through this program. The result that I arranged and analyzed the making process of artworks, the photos of the resultant, etc. as such is as follows : Firstly, from this program being proceeded as art-centered STEAM class, the student's systematic problem-solving ability was improved in his ability of integrated thinking to transform the literary contents into artistic one. Secondly, the student obtained the emotional experience such as interest in the class, self-confidence, intellectual satisfaction, self-fulfillment, etc. through art-centered STEAM class using ten art expression techniques. Thirdly, the student's mind willing to cooperate, communicate with his friends, and care for them was ripened in the process of problem-solving. Fourth, the student's self-confidence was further instilled when presenting famous artists and their artworks in the introduction and finale of ten art expression techniques. Likewise, the statistic values on the fields of student's ability of integrated thinking and emotional experience illustrate that over the majority of the students showed improvement in the ability of creative expression with confidence as well as higher interest and concern upon this program.

A Study on the DWI and Pathologic Findings of Cancer Cells (암 세포주의 확산강조영상과 병리학적 관계에 관한 연구)

  • Seong, Jae-Gu;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.239-244
    • /
    • 2011
  • In this study, we evaluated diffusion weighted imaging (DWI) to investigate whether the DWI parameters can predict characteristic parameters on pathologic specimens of tumor or not. CFPAC-1 was injected subcutaneously on the back flank of athymic nude mice (n=13) then two tumors were initiated on each mouse (2${\times}$13=26 tumors). The mice were sacrificed to make specimen immediately after initial MR imaging then were compared with the MR image. A dedicated high-field (7T) small-animal MR scanner was used for image acquisitions. A T1 and T2 weighted axial image using RARE technique was acquired to measure the T2 values and tumor size. DWI MR was performed for calculating ADC values. To evaluate tumor cellularity and determine the levels of MVD, tumor cells were excised and processed for H-E staining and immunostaining using CD31. T2 values and ADC values were computed and analyzed for each half of the tumors and compared to the correlated specimens slide. Median ADC within each half of mass was compared to the cellularity and MVD in the correlated area of pathologic slide. The mean of ADC value is $0.7327{\times}10^{-3}$ $mm^2/s$ and standard deviation is $0.1075{\times}10^{-3}$ $mm^2/s$. There is a linear relationship between ADC value and tumor necrosis (R2=0.697, p< 0.001). DW image parameters including the ADC values can be utilized as surrogate markers to assess intratumoral neoangiogenesis and change of the internal structure of tumor cells.

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Relationships among CEO Image, Corporate Image and Employment Brand Value in Fashion Industry

  • Ko, Eun-Ju;Taylor, Charles R.;Wagner, Udo;Ji, Hyun-Ah
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.4
    • /
    • pp.307-331
    • /
    • 2008
  • The CEO and the Corporate Image is considered very important in the aspect of marketing. The fact that CEO image itself influences the company or value of the product directly and indirectly has been verified through many cases. Recently, the differentiation of products and services between companies became difficult because the disparity in technique between companies retrenched. As a result, the rate of people who decide to purchase or invest their money based on the corporate image or reputation has been increased. Also in the knowledge society like today, the talented employees are the company's customer and the company's necessity for managing those brains of marketing perspective on how to satisfy and attract the customers is being embossed. The Fashion industry is one of the most value-added industry and in those value-added businesses, the most important factor is the human resources' knowledge power. However the study of the relationships among the CEO image, the corporate image and employment brand value in fashion industry has not been carried out yet. This research considers that dynamic relationship exists among the CEO image, corporate image and employment brand value that affects a company's main goal of pursuing benefits and intends to investigate the relationships of the three concepts. The specific purposes of this study were, 1) to analyze the impact of CEO image on a corporate image, 2) to analyze the impact of corporate image on employment brand value, 3) to analyze the impact of CEO image on employment brand value, 4) to analyze whether corporate image plays a mediating role in the relationship between CEO image and employment brand value or not. A survey design with a structured questionnaire was employed for this research. A convenience sample of 398 subjects was selected from two groups, which are university students majoring in fashion and practitioners working in fashion industry. For the data analysis, descriptive statistic (i.e., frequency, percentage), factor analysis, and multiple regression analysis were used by utilizing SPSS 12.0 for Windows program. The results for this research are as follows, first, the study of the impact of CEO image (i.e., Managerial Competence, Reliability/Leadership, Personal Attractiveness) on corporate image (i.e., Product Image, Corporate Social Responsibility Image, Corporate Cultural Image) brought conclusion that the CEO image generally affected the corporate image in fashion industry. Managerial Competence and Reliability/Leadership affected Product Image, Corporate Social Responsibility Image and Corporate Cultural Image. However, while CEO's Personal Attractiveness affected Product Image and Corporate Social Responsibility Image, it did not affect Corporate Cultural Image. Second, the study of the impact of corporate image on employment brand value brought conclusion that corporate image (i.e., Product Image, Corporate Social Responsibility Image, Corporate Cultural Image) affected employment brand value. Corporate Cultural Image affected employment brand value the most and then the Corporate Social Responsibility Image and Product Image. Third, the study of the impact of CEO image on employment brand value brought conclusion that CEO image (i.e., Managerial Competence, Reliability/Leadership, Personal Attractiveness) affected the employment brand value. CEO's Reliability/Leadership affected the employment brand value the most and then CEO's Personal Attractiveness and CEO's Managerial Competence. Forth, the study examined whether corporate image plays a mediating role in relationship of CEO image and employment brand value and concluded that it does. Corporate image played a full mediating role between CEO's Managerial Competence and employment brand value while it played a partial mediating role between CEO's Reliability/Leadership and CEO's Personal Attractiveness. This study is meaningful in a sense that it examines the relationship among the CEO image, corporate image and employment brand value which has not been carried out yet in fashion industry. It will ultimately contribute to the success of a fashion company by providing useful information of establishing strategies for managing proper the CEO and the corporate image to the fashion company and operating the talented employees.

  • PDF