• Title/Summary/Keyword: Station Line

Search Result 779, Processing Time 0.023 seconds

Guideline for Preparation of Manuscript for Proceedings (신분당선 CBTC구간과 분당선 ATC구간의 절체운전에 대한 고찰)

  • Jang, Kwang-Dong;Cha, Ki-Ju;Kang, Deok-Won;Lee, Jong-Seong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.2017-2022
    • /
    • 2009
  • Sinbundang Line(SBL) Train moves the transition zone where is located between Jeongja station and Migeum station switched over from Communication Based Train Control (CBTC) system area to Automatic Train Control (ATC) system area and viceversa. The SBL train to move the between SBL and Bundang Line is needed to install the Specific Transmission Module (STM) on SBL Line for interface with Bundang Line; STM receives from speed code from Bundang Line. So we suggested the method to ensure mutual compatibility and reliability for train operation on each other signaling system.

  • PDF

Load Factor Decrease In The Seoul Metro Circle Line through Analyzing Passenger OD Demand (2호선 혼잡구간 OD수요 분리유도를 통한 혼잡도 개선 방안 (교통카드 빅데이터 분석을 중심으로))

  • Eom, Jin Ki;Song, Ji-Young;Lee, Kwang-Sub
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.6
    • /
    • pp.457-465
    • /
    • 2014
  • This study proposes a policy for urban railway travel demand management system in order to decrease the load factor of the Seoul metro Circle line, particularly for the segment between Sadang and Samsung stations, through analyzing the transit smart card data. We propose mixed train operations of the existing Circle line and a line that goes toward Samsung station in order to transport passengers that have two distinct groups: those with the destination of Samsung station and those with destinations after Samsung station. The introduction of a mixed train operation that encourages passengers passing through Samsung station to take a Circle line train will decrease the congested load factor by 11.3% during the morning peak hours using the mixed train operation of the Circle and Samsung lines. This policy could be an effective method to decrease the load factor and improve the comfort of rail passengers without extra investment in the railway facilities.

A New Spray Chrysanthemum Cultivar 'Yes Line' with Single Type and Purple Color (자주색 홑꽃 스프레이국 신품종 'Yes Line' 육성)

  • Pak, Ha-Seung;Choi, Taeg-Yong;Won, Mi-Kyoung;An, Jong-Beom
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.4
    • /
    • pp.317-320
    • /
    • 2008
  • A new spray chrysanthemum(Dendranthema grandiflorum Ramat.) cultivar 'Yes Line' was originated from a cross between 'T22319' and 'SP02-037-13'. This cultivar was tested on the characteristics from 2004 to 2007 for the evaluation and selection including shading and retarding culture. The natural flowering time of 'Yes Line' is late October, but year-round production is possible by shading, lighting and retarding culture. This cultivar was single in flower type, with a color of red-purple(RHS 74C), with the flowers of 21.4 per stem. 'Yes Line' showed the vase life of 16.5 days in autumn season. The diameters of flower and flower center were 4.3 cm, 1.2 cm respectively. The days to flower under the short day treatment was 7.5 weeks and preference of consumers were high at 3.86 ranged up to 5.00. It has resistance to white rust and was possible to cultivate all-year-round.

Waterhammer for the In-Line Intake Pumping Station with Air Chamber (에어챔버가 설치된 인라인 취수펌프장에서 수격현상)

  • Kim, Kyung-Yup;Ahn, Cheoul-Hong;Kim, Bum-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.

Analysis of Strategies for Installing Parallel Stations in Assembly Systems

  • Leung, John W.K.;Lai, K.K.
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • An assembly system (AS), a valuable tool for mass production, is generally composed of a number of workstations and a transport system. While the workstations perform some preplanned operations, the transport system moves the assemblies by special designed pallets from one station to another. One common problem associated with automatic assembly systems is that some assembly operations may have relatively long cycle times. As a consequence, the productivity, as determined by the operations with the longest cycle time, can be reduced significantly. Therefore, special forms of parallel workstations were developed to improve the performance of an assembly system. In this paper, three most commonly used parallel stations: on-line, off-line and tunnel-gated stations in a free transfer assembly system are studied via discrete event simulation. Our findings revealed that the off-line parallel system has the best performance because the two independent parallel stations can lower the buffer requirement; reduce the sensitivity to variability of processing time and balance of a line. On-line parallel systems were found to have a relatively poor performance, because the operations of two parallel stations block each other, and higher buffer capacity is required to achieve similar capacity. The tunnel-gated system was more efficient than the on-line system since the first parallel station can operate independently. More importantly, we have quantified the productivity of the three different strategies mentioned. Engineers can choose the optimal strategies for installing parallel stations under their working environment.

Optimal Train Driving Strategy for Energy Saving (에너지소비 절감을 위한 열차최적운전)

  • Son, Chang-Hun;Seo, Byung-Shul
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.888-894
    • /
    • 2011
  • This paper is a study of optimal train driving strategy to minimize the energy consumption. Optimal driving strategy can be analyzed as an optimal problem which have constraints by using Largrangian Function and Kuhn-Tucker condition. We simulate the section between Konkuk University Station and Seongsu Station which is on outer circle line of the Seoul Metro line No.2 by using MATLAB and consider the straight level track and the speed limit.

  • PDF

Optimal Inspection Plan for a Flexible Assembly Line

  • Yoo, Seuck-Cheun
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.18 no.1
    • /
    • pp.97-117
    • /
    • 1993
  • This paper considers inspection station location problem for a flexible assembly line that consists of multiple stages. By considering the trade-off between locating an station at an "early" stage and at a "late" stage, we have developed some dominance relations on a graph. Based on the dominance relations, we then present an algorithm that finds an optimal inspection plan and a heuristic approach that finds a near-optimal inspection plan. The effectiveness of these two algorithms is demonstrated by two numerical examples. numerical examples.

  • PDF

A Result Analysis on Field Test for Localization Development of Axle Counter System (Axle Counter System 국산화 개발을 위한 현장시험 결과분석)

  • Ko, Joon-Young;Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6214-6220
    • /
    • 2015
  • A track circuit has used stably more than 100 years for detecting train position, but solution of track circuit sort circuit incapacity due to a rust is necessary for side line in station yard, coast line and level crossing for conventional line in rural line. Domestically, Axle Counter System(ACS) has partially used for Hot Box System for high speed line and turnout for CBTC system. In contrast, most of countries has used ACS not only trunk line but also rural line and its application has increased for metro, electric car and industrial railway. In this paper, we has verified the operating status of ACS which installed with existing track circuit through log analsis to implement pilot application in mail track and turnout in station yard. And interface test with interlocking system has conducted at Obong shunting yard, as well as Cheongju station and has analyzed test result. Based on a test result, we made fail safe design, manufacturing skill and established system requirement specification for the smooth operation and maintenance.