• 제목/요약/키워드: Station Bus

검색결과 170건 처리시간 0.025초

바이모달트램용 전용선로를 고려한 스마트 정거장의 구성 및 역할 (Configuration and Role for Smart Station Considering of the Special mad of Bimodal Tram)

  • 이강원;윤희택;목재균;김영민;김태원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.260-269
    • /
    • 2009
  • A station is the place for the passenger who load the baggage or for bus, taxi, train to stop regularly. For example, bus stop which is installed on many areas for bus as a public transportation provides some space to the passenger who waits for getting on the bus. The bus stop built up recently carries on many kinds of function to make the passenger convenient different from the conventional simple bus stop. Smart station for Bimodal Tram combined with ITS(Intelligent Transportation System) technology has the advantages of both new and conventional stations. This paper has investigated the function and role of newly developed smart station which is able to be adaptive to the rapid variation of road station.

  • PDF

지역 간 철도 이용객의 접근통행 패턴 연구 (An Analysis of Access and Egress Mode Choice to Regional Railway Station using Transit Smart Card Data (a case of Seoul station))

  • 최명훈;엄진기;이준;문대섭;송지영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.595-600
    • /
    • 2011
  • This study analyzed passenger's access modes that connect to regional railway station and developed a model of access mode choice based on transit smart card data of Seoul station as a case study. The study boundary includes sixteen bus stops around the station. The results show that most passengers access to station have less than two transfers. Of total 15000, eighty percent of passengers use metro and the rest of people take a bus. Interestingly, it is found that almost same proportions of passengers use metro and bus for egress the station. Consequently, metro is found to be most likely used mode compared to bus for both access and egress trips.

  • PDF

버스터미널 현황음 특성에 관한 실험적 연구 (A Experimental Study for Characteristic of Element Sound to Bus Terminal)

  • 송혁;박현구;송민정;장길수;김선우
    • KIEAE Journal
    • /
    • 제3권4호
    • /
    • pp.33-36
    • /
    • 2003
  • Bus station is a public space which many people use and various activities are occurred in urban life. Main activities are waiting for departure or passengers with the feelings of joys and sorrows. Also sound information including announcing message of arrival and departure are to be considered carefully. Considering these roles of bus station, creating acoustic amenity is a prerequisite to the spaces. In this study, the spaces of bus station were classified into 4 spaces such as approaching path, waiting palace, departure and arrival platform. Observation survey was conducted to extract various activities in the view point of sound in each space. And subjective response was analyzed before and after introducing prepared sounds.

대전광역시의 버스 정류장 디자인 (DID Bus Station Design for Daejeon City)

  • 임오연
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.86-89
    • /
    • 2008
  • In this paper, bus station design is presented as a component of public design to develop the integrated city public image of Daejeon Metropolitan City through the study of city characteristics and the direction of future development. Design concept is the mutual understanding of public image and human centered sense, and comfortable bus station which is correspond with future development direction and applicable for digital informationization is selected. Design components are bus shelter, information board, bench, vending machine, a wastebasket, billboards and so forth.

  • PDF

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.

디지털변전소 통합 IED 용 Process Bus 네트워크 통신지연 시뮬레이션 연구 (A Study on Simulation Analysis for the Transmission Delay on the Process bus network in IEC 61850 Digital Substation)

  • 김석곤;안용호;장병태;최종기;이남호;한정열;이유진
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.18-22
    • /
    • 2015
  • Digitalization of the substation in Korea has been in progress so far with focusing on Station Bus. However, its application to Process Bus has been delayed due to some technical issues. IEDs based on Process Bus use the data values of SV and GOOSE. As the size of communication data on Process Bus is comparatively bigger than that of Station Bus, it is very important for the evaluating the performance of Process Bus to analyze the transferring speed and quality of data from the first equipment, which is located on process level, to station level. According to the results of related studies, it is said that the most important factor for the design and operation of Process Bus network is the communication delay with consideration of the volume of packets. In the paper, the results of performance test for the network with and without application of VLAN on Process Bus system that uses integrated IEDs are presented. Additionally, the paper proposes the optimal method to analyze the communication delays of network systems through evaluating the maximum delay time, link process ratio and the amount of lost packets by using a simulation tool.

공공디자인에 있어서 이용자와 주변 환경을 고려한 디자인 모델구축 - 버스정류장을 중심으로 (Establishment of design model considering surrounding environment and users in public design - Focused on the bus station)

  • 형성은
    • 감성과학
    • /
    • 제12권4호
    • /
    • pp.451-460
    • /
    • 2009
  • 본 연구는 공공시설물인 버스정류장의 특성을 조사하기 위해 이용자 행동유형(행동조사+선호도)과 관련된 연구를 진행하였다. 세부적인 분석에서는 버스정류장 속성분석과 특성을 조사하기 위해 각 지역자치단체에 설치된 50개의 샘플을 대상으로 수량화 3류(Quantification theory type 3) 분석을 실시하였다. 실험결과 버스정류장은 유동인구가 많음/적음, 기능적인, 단순함의 4개 축과 회사 밀집형 대도시, 지역성이 강한 지방도시, 유동인구가 많은 학교 앞, 한적한 시골마을, 박물관 같은 특정장소, 유동인구가 많은 농촌지역의 특성에 따라 버스정류장의 유형에 차이가 있는 것으로 조사되었다. 위와 같이 본 연구에서는 지역적 특성에 맞도록 시설물 자체의 조형성 이외에도 지역 환경, 이용자 특성 등이 고려된 디자인이 진행될 수 있도록 버스정류장 속성을 종합하여 세부항목을 제시하였다. 또한, 위의 내용을 바탕으로 지역 환경적 특성에 맞는 디자인과 모델이 적용된다면 앞으로 공공시설물로서 이용자에게 보다 긍정적인 평가를 받을 수 있는 공공디자인이 진행될 것이다.

  • PDF

미국 캘리포니아 수소 버스와 충전소 운영 현황과 정책 고찰 (Status of Hydrogen Bus Operations and Charging Stations and Policy Reviews in California, USA)

  • 김창모;진상규;진광성;권영인;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.463-469
    • /
    • 2022
  • After reviewing the current status of hydrogen buses and hydrogen charging stations in the United States, as well as related laws and programs, it was found that the federal and state governments supported the supports of hydrogen buses and the deployment of hydrogen charging infrastructure through various policies and programs. In order to promote the spread of domestic and overseas hydrogen buses and hydrogen charging infrastructure, it is necessary to develop and apply various legal systems and programs that can provide incentives to hydrogen bus manufacturers, hydrogen charging station installers, hydrogen bus operating organizations and entities. It is necessary to develop and apply various legal systems and programs that can provide incentives to hydrogen bus manufacturers, hydrogen charging station installers, hydrogen bus operating organizations and entities.

신개념 모듈형 스마트정거장시스템의 구축에 관한 연구 (Study on the construction of New Conceptual Modular Smart Station)

  • 이강원;윤희택;김영민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2008
  • General bus stop is very simple and have some problem to protect the passengers and don't have any proper information messenger for the convenience of bus riding in spite of present initiative bus information system. However, this paper have introduced new conceptual modular-smart station avaliable to both public bus and bimodal tram. It can secure the passenger's safety from other danger attributes like running car or unexpected natural disaster and supply the passengers the variable information from display which is connected to the control center. Therefore, modular-smart station is both shelter and information messenger for passenger's safey and convenience.

  • PDF

Configuration of Actuator and Sensor Interface Bus Network using PLC

  • Luu, Hoang-Minh;Park, Young-San
    • 해양환경안전학회지
    • /
    • 제20권3호
    • /
    • pp.318-322
    • /
    • 2014
  • A kind of field bus called Actuator and Sensor interface bus(AS-i) was designed in this paper. The configuration of AS-i network system used Application Specific Integrated Circuit(ASIC) SAP5S chip and PLC S7-200 station, which included CPU 224 and AS-i master module CP 243-2. We also created an example program for PLC S7-200 to control AS-i network. The fire and smoke detection system was made with AS-i network system that was designed. This system had got more advantages than other system such as number of stations, easy installation, wide working area, etc. And designed system can be used as a partner network for higher level field bus networks.