• 제목/요약/키워드: Station Accident status

검색결과 20건 처리시간 0.026초

철도역사 사상사고 예방대책 수립을 위한 기초 연구 (Development of Railway Station Safety Measures for Passenger)

  • 곽상록;최돈범;박찬우;조연옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.763-767
    • /
    • 2011
  • As accident rate have been reduced into half since 2005, no train accident fatality occurred in recent year. Level crossing accident also been reduced that no more than 5 fatalities occurred every year. As a result 98% of accident fatalities occurred in station and track. So railway station safety measures are more and more important but only few research have been done on railway station safety. In this study status on safety measures on railway stations are reviewed and basic research have been done based on expert interview for the development of new safety measures.

  • PDF

발전소에서 운전 중인 활성 6.6kV 전력 케이블의 고장상태를 파악하는 장치의 개발 (Developing Equipment to Detect the Deterioration Status of 6.6kV Power Cables in Operation at Power Station)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.197-203
    • /
    • 2014
  • 발전소의 전력 케이블 시스템에서 발생할 수 있는 사고를 예측하고 방지하는 기술이 필요하다. 사선 상태에 있는 케이블의 동작 특성을 진단하기 위하여 부분방전 및 $tan{\delta}$ 법이 사용되고 있으나, 케이블이 갖고 있는 문제점들을 사전에 발견하기란 쉬운 일이 아니다. 이 논문에서 우리가 연구한 케이블은 (주)서부 발전소에서 설치되어 운전 중인, 발전 운영에 핵심 역할을 하는 6.6kV 고전압 배전 선로이다. 케이블의 온도 및 전류를 측정하고, 이를 바탕으로 절연저항을 측정하기 위한 장치를 개발하였다. 이 장치를 발전소 현장에 시험 설치를 하였고, 동작 중인 케이블의 수명을 평가하기 위한 동작특성의 진단을 성공적으로 마무리 하였다. 진단 데이터를 분석 평가함으로써 단기적으로는 운전 중 6.6kV 케이블 시스템의 고장상태를 파악하는데 활용되며, 장기적으로는 발전소 부하에서의 6.6kV 케이블 시스템의 설치 및 운영에 있어서 원가를 절감하기 위한 노력에 기여하고자 한다.

119 구급대 구급차 교통사고 현황 분석 (Analysis of traffic accidents involving 119 emergency)

  • 이정호;신동민
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.35-47
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate both the occurrence status of emergency vehicles traffic accidents and contents of the experiences of emergency medical technicians (EMTs) in fire station. Methods: A self-reported questionnaire was completed by 451 EMTs in fire stations in 6 cities provinces from February 9, 2017 to February 27, 2017. Results: Of 451 EMTs, 207 (45.9%) had traffic accidents experience. Regarding environment-related features, results indicated hour (12~18 hours), place (national highway), traffic flow (smooth), weather (clear), season (winter), and day (Friday). Regarding correlation analysis of differences in the number of ambulance traffic accidents pursuant to general features of accident-experienced drivers as a human factor, there were no significant differences in recruitment, driving careers of regular cars, driving careers of fire engines, and class but there were significant differences in fire-fighting careers. Accident experience in the group with careers over 6 years and less than 10 years higher than in the other groups. Conclusion: Efforts to expand fire engine driving education programs for the prevention of traffic accidents involving 119 emergency vehicles are required.

중대사고를 대비한 원전비상통신시스템 개념설계 (Conceptual Design of Emergency Communication System to Cope with Severe Accident in Nuclear Power Plants)

  • 손광섭
    • 전자공학회논문지
    • /
    • 제51권5호
    • /
    • pp.58-69
    • /
    • 2014
  • 후쿠시마 사고와 같은 중대사고에 대비하기 위하여 극한환경 내에서도 동작하여 원자력 발전소 내부 상태에 관련된 계측신호를 취득하고, 사고복구에 필요한 밸브, 펌프 등과 같은 비상기기를 작동시킬 수 있는 극한환경용 제어기기와 발전소로부터 최소 30km 떨어진 곳에서 발전소 내부 상황을 감시하고, 제어할 수 있는 모바일 원격 제어실 등으로 구성된 비상대응시스템이 필요하다. 본 논문에서는 극한환경용 제어기기와 모바일 원격 제어실과의 연계를 위한 비상대응시스템 개념 설계 및 성능분석에 대하여 논의하였다. 비상통신시스템은 IEEE 802.11 기술표준을 이용한 지상망과 천리안 위성을 이용한 위성망의 이중화 시스템으로 구성되고, 각 시스템에 대하여 통신링크 버짓, Throughput, 지연시간을 분석하였다.

화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구 (A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station)

  • 박성희;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.187-193
    • /
    • 2018
  • 국내에서의 전력에 대한 수요는 점진적으로 증가하고 있는 추세이다. 수요에 대응하기 위한 발전소는 기능이 다양해지고 효율이 점차 커져야 한다. 발전소 내의 전력 기기에서 사고가 발생하면 막대한 경제적 손실 및 장애를 초래하게 된다. 사고 발생의 원인 중의 하나로서 절연 성능이 저하 된 케이블이 있다. 케이블 사고를 미연에 방지하기 위하여 절연의 상태를 감시하고 확인하여야 한다. 케이블 사고는 연결 부위인 접속에서 발생하는 사고가 대부분을 차지한다. 본 연구와 관련하여 우리는 접속부 상태를 판별하기 위한 장비를 개발하였고, 한국서부발전(주)의 현장에 설치하여 운용 중이다. 본 논문에서는 현장에서 설치 운용 중인 장비에 대한 설명과 더불어 설치 운용된 결과를 통해 케이블의 수명을 예측할 수 있는 고전압 케이블 접속재의 안정적 사용을 위한 온라인 감시진단기법 중에서 사고가 가장 빈번하게 발생하는 접속부에 대해 안정적인 사용을 위한 진단의 정확성과 신뢰성을 향상시키기 위한 연구를 하였다. 이 논문에서 하드웨어 구성을 위주로 우리가 개발한 장비를 소개한다.

마코프 모델을 이용한 원전 비상 통신 시스템 성능 분석 (Performance Analysis of Emergency Communication System of Nuclear Power Plant using Markov Model)

  • 손광섭
    • 전자공학회논문지
    • /
    • 제51권3호
    • /
    • pp.10-21
    • /
    • 2014
  • 후쿠시마 원전사고는 자연재해에 의한 중대사고 발생 시 전원공급 중단 및 극한 환경으로 인해 발전소 내부 상황을 정확하게 파악하지 못하였고, 대부분의 계측제어시스템이 그 기능을 제대로 발휘하지 못해 비상냉각기능이 상실되어 수소폭발 및 다량의 방사능이 누출된 사고였다. 본 논문에서는 중대사고 발생 시에도 발전소 내부 상황을 감시하고, 적절히 제어할 수 있는 비상대응시스템에 대하여 소개하고, 비상대응시스템에 사용되는 무선통신망의 성능요구사항에 대해서 논의하고, 요구사항을 만족시킬 수 있는 비상통신망의 성능을 마코프 모델을 이용하여 분석하였다.

전라남도 섬과 해상에서 발생한 환자의 현황분석 (Status analysis of patients on islands and seas of Jeollanam-do)

  • 최영주;윤종근
    • 한국응급구조학회지
    • /
    • 제26권2호
    • /
    • pp.87-96
    • /
    • 2022
  • Purpose: By analyzing the health status of emergency patients on islands in the Jeollanam-do province, this study aims to provide basic data for proposed future medical emergency services on the islands. This information includes monthly and hourly statistics on patients' characteristics, patient frequency, an analysis of first aid procedures, response times, and time spent at hospitals. Methods: The study analyzed the monthly and hourly frequency of emergency patients, first aid status and procedures, general patient characteristics, accident types, patient cognitive status and agility, marine police response times, and frequency and percentile of hospital dispatch times. Results: 1Q and #q show the highest patient turnover rate in one year. 50.5% of daily patients are admitted between 4 PM and 12 PM. The hospital dispatch time is within a one- to two-hour window for 54.0% of all patients. Conclusion: The emergency medical service system for the Jeollanam-do province islands and seas is available to all Korean residents, citizens, and visitors. It is necessary to implement an emergency medical system for the relevant organizations.

전력케이블 열화 감시방안에 관한 연구 (A Study on Monitoring Means of Insulation deterioration of Electric Power Cable)

  • 한학수;민경윤;유기선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

공급기지 부취설비 운영에 의한 천연가스 부취 농도 최적화 (Optimization of Odor Concentration by Operation of Small Station Odorizer)

  • 이승호;송택용;백영순
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.36-44
    • /
    • 2001
  • 부취 농도가 낮을 경우 안전사고 발생의 우려가 있고, 과다 주입할 경우 주배관, 정압 설비 등의 수명 단축 및 환경오염의 문제를 야기 시킬 수 있다. 또한 부취제의 물성상 일정량이 배관 등에 물리$\cdot$화학흡착 또는 반응을 통하여 손실되어 적정 농도 유지에 어려움이 있고 비경제적이다. 따라서 부취제의 농도를 적정하게 유지하는 것은 매우 중요하다 본 연구에서는 배관내 부취제 농도의 적정관리를 위해 국내외 부취 설비와 농도관리현황, 소규모 설비의 특징과 장단점을 분석하였다. 또한 소규모 시스템의 적용시 운영방안과 타당성 분석을 제시하였다.

  • PDF

Holistic Approach to Multi-Unit Site Risk Assessment: Status and Issues

  • Kim, Inn Seock;Jang, Misuk;Kim, Seoung Rae
    • Nuclear Engineering and Technology
    • /
    • 제49권2호
    • /
    • pp.286-294
    • /
    • 2017
  • The events at the Fukushima Daiichi Nuclear Power Station in March 2011 point out, among other matters, that concurrent accidents at multiple units of a site can occur in reality. Although site risk has been deterministically considered to some extent in nuclear power plant siting and design, potential occurrence of multi-unit accident sequences at a site was not investigated in sufficient detail thus far in the nuclear power community. Therefore, there is considerable worldwide interest and research effort directed toward multi-unit site risk assessment, especially in the countries with high-density nuclear-power-plant sites such as Korea. As the technique of probabilistic safety assessment (PSA) has been successfully applied to evaluate the risk associated with operation of nuclear power plants in the past several decades, the PSA having primarily focused on single-unit risks is now being extended to the multi-unit PSA. In this paper we first characterize the site risk with explicit consideration of the risk associated with spent fuel pools as well as the reactor risks. The status of multi-unit risk assessment is discussed next, followed by a description of the emerging issues relevant to the multi-unit risk evaluation from a practical standpoint.