Abstract
In case of low odor level, accident probabilities are very high Otherwise, when the odorant concentration is too high, the deterioration of pipeline and governor facilities and the environmental problems may occur. Odorants fade in the pipeline and other equipment due to physical and chemical adsorption and reactions with odorant and materials. So, it is very important to maintain odorant concentration properly In this study, the current status of odorization technologies has been reviewed. And the characteristics of small odorant system have been analyzed. In case that the small odorant system Is introduced in our country, this paper is proposed the feasible management plan and showed feasibility results through the analysis of current available technology.
부취 농도가 낮을 경우 안전사고 발생의 우려가 있고, 과다 주입할 경우 주배관, 정압 설비 등의 수명 단축 및 환경오염의 문제를 야기 시킬 수 있다. 또한 부취제의 물성상 일정량이 배관 등에 물리