• Title/Summary/Keyword: Static sensitivity

Search Result 267, Processing Time 0.028 seconds

Development of Nonlinear Static Design Sensitivity Analysis Based ANSYS (ANSYS 비선형 정적설계민감도해석 외부모듈 개발)

  • Choi, Byung-Nam;Jung, Jae-Jun;Yoo, Jung-Hoon;Lee, Tae-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.543-547
    • /
    • 2001
  • CAE has been settled down to an indispensable tool for the simulation of a mechanical system according to the development of computer-aided analysis rapidly. Particularly finite element programs have advanced to the one of most valuable things in the filed of CAE due to the remarkable progress in the implementation. But since this analysis tool mostly provides the result of the analysis, it cannot satisfy designers who are seeking for information to improve their designs. Therefore, design sensitivity analysis or optimization module has been incorporated into commercial FEA programs to satisfy the desire of designers since 1990s. Design sensitivity analysis is to compute the rate of change of response with respected to design variable. Design sensitivity analysis is classfied into static design sensitivity analysis, Eigenvalue design sensitivity analysis and dynamic design sensitivity analysis. In this research, it will be presented to nonlinear static design sensitivity analysis formulation and nonlinear static design sensitivity analysis external module based ANSYS have been developed and illustrated an example to verify the developed module.

  • PDF

Sensitivity Analysis of the Explicit Elasto-plastic Finite Element Method and Application to the Quasi-static Deformation (외연적 탄소성 유한요소해석에서의 민감도 해석과 준정적 변형에의 응용)

  • Kim, Se-Ho;Huh, Hoon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.402-407
    • /
    • 2001
  • Sensitivity analysis scheme is developed in the elasto-plastic finite element method with explicit time integration using direct differentiation method. The direct differentiation is concerned with the time integration, constitutive relation, shell element with reduced integration and the contact scheme. Sensitivity analysis results are mainly examined with the highly nonlinear and quasi-static problem with the complicated contact condition. The result shows stable sensitivity especially in the sheet metal forming analysis.

  • PDF

A Study on the System Loss Minimizing Algorithm by Optimal Re-location of Static Condenser Using System Power Loss Sensitivity (계통손실 감소를 위한 전력용 콘덴서의 適正 再配置에 대한 연구)

  • 이상중;김건중;정태호;김원겸;김용배
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.1
    • /
    • pp.21-24
    • /
    • 1995
  • The larger and the more complicated the system size and configuration grow, the more serious the system loss problem becomes. Exessive system loss causes severs system voltage depression, which even may result in system voltage collapse. This paper proposes an effective tool for minimizing the system power loss by optimal re-location of the static condenser based on the system loss sensitivity index .lambda.$_{Q}$. It is possible to determine the optimal location and amount of VAR investment for minimizing the system loss by priority of .lambda.$_{Q}$ index given for each bus. Several computational techniques for avoiding divergency of the load flow solution are proposed. The loss sensitivity index .lambda.$_{Q}$ uses information of normal power flow equations and their Jacobians. Two case studies proved the effectiveness of the algorithm proposed.posed.

  • PDF

A Study on the Static Sensitivity Analysis Algorithm Using the Transfer of Stiffness Coefficient (강성계수의 전달을 이용한 정적 감도해석 알고리즘에 관한 연구)

  • Choi, Myung-Soo
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.82-89
    • /
    • 2001
  • To design a structural or a mechanical system with the best performance, the main procedure of a typical design usually consists of repeated modifications of design parameters and the investigation of the system response for each set of these parameters. But this procedure requires much time, effort and experience. Sensitivity analysis can provide systematic information for improving performance of a system. The author has studied on the development of the structural analysis algorithm and suggested recently the transfer stiffness coefficient method(TSCM). This method is very suitable algorithm to a personal computer because the concept of the TSCM is based on the transfer of the nodal stiffness coefficients which are related to force and displacement vectors at each node. In this paper, a new sensitivity analysis algorithm using the concept of the TSCM is formulated for the computation of state variable sensitivity in static problems. The trust of the proposed algorithm is confirmed through the comparison with the computation results using existent sensitivity analysis algorithm and reanalysis for computation models.

  • PDF

Cutting Force Estimation and Feedrate Adaptive Control Using Spindle Motor Current (주축전류신호를 이용한 절삭력의 추정과 이송속도 적응제어)

  • 김기대;이성일;권원태;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.150-156
    • /
    • 1996
  • Static variations of cutting forces are estimated using spindle motor current. Static sensitivity of spindle motor current is higher than feed motor current. The linear relationship between the cutting force and RMS value of the spindle motor current is obtained. Using cutting force estimation, tool overload in milling process can be well detected, and cutting force is regulated at a constant level by feedrate adaptive control.

  • PDF

Effect of Constitutive Material Models on Seismic Response of Two-Story Reinforced Concrete Frame

  • Alam, Md. Iftekharul;Kim, Doo-Kie
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.2
    • /
    • pp.101-110
    • /
    • 2012
  • This paper focuses on the finite element (FE) response sensitivity and reliability analyses considering smooth constitutive material models. A reinforced concrete frame is modeled for FE sensitivity analysis followed by direct differentiation method under both static and dynamic load cases. Later, the reliability analysis is performed to predict the seismic behavior of the frame. Displacement sensitivity discontinuities are observed along the pseudo-time axis using non-smooth concrete and reinforcing steel model under quasi-static loading. However, the smooth materials show continuity in response sensitivity at elastic to plastic transition points. The normalized sensitivity results are also used to measure the relative importance of the material parameters on the structural responses. In FE reliability analysis, the influence of smoothness behavior of reinforcing steel is carefully noticed. More efficient and reasonable reliability estimation can be achieved by using smooth material model compare with bilinear material constitutive model.

Structural Damage Detection Method Using Sensitivity Matrices (민감도행렬을 사용한 구조물의 손상추정법)

  • 윤정방;김두기
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.117-126
    • /
    • 1996
  • Damage detection methods using structural tests can be divided into two methods, i.e., static and dynamic. The static methods which use the stiffness properties of the structure are simpler than the dynamic methods. However, static approaches are very sensitive to the displacement measurement noises and modeling errors. The dynamic methods also have limitations in acquiring the natural frequencies and mode shapes of the high frequencies. In this study, a method for the structural damage assessment using sensitivity matrices is developed, in which the drawbacks of the static and dynamic methods can be compensated. Based on the measurement data for the static displacements and dynamic modal properties, the damage locations and the degree of damage are determined using the presented sensitivity matrix method. The efficiency of the proposed method has been examined through numerical simulation studies on truss type structures.

  • PDF

Neck Formation in Drawing Processes of Fibers

  • Chung, Kwansoo;Yoon, Hyungsop;Youn, Jae Ryoun
    • Fibers and Polymers
    • /
    • v.2 no.1
    • /
    • pp.140-143
    • /
    • 2001
  • To better understand the formation of necking in drawing processes of fibers, strain distributions during drawing processes have been analyzed. For simplicity, one-dimensional incompressible steady flow at a constant temperature was assumed and quasi-static model was used. To describe mechanical properties of solid polymers, non-linear visco-plastic material properties were assumed using the power law type hardening and rate-sensitive equation. The effects of various parameters on the neck formation were matematically analyzed. As material property parameters, strain-hardening parameter, visco-elastic coefficient and strain-rate sensitivity were considered and, for process parameters, the drawing ratio and the process length were considered. It was found that rate-insensitive materials do not reach a steady flow state and the rate-sensitivity plays a key role to have a steady flow. Also, the neck formation is mainly affected by material properties, especially for the quasi-static model. If the process length changes, the strain distribution was found to be proportionally re-distributed along the process line by the factor of the total length change.

  • PDF

Sensitivity analysis of mechanical behaviors for bridge damage assessment

  • Miyamoto, Ayaho;Isoda, Satoshi
    • Structural Engineering and Mechanics
    • /
    • v.41 no.4
    • /
    • pp.539-558
    • /
    • 2012
  • The diagnosis of bridge serviceability is carried out by a combination of in-situ visual inspection, static and dynamic loading tests and analyses. Structural health monitoring (SHM) using information technology and sensors is increasingly being used for providing a better estimate of structural performance characteristics rather than above traditional methods. Because the mechanical behavior of bridges with various kinds of damage can not be made clear, it is very difficult to estimate both the damage mode and degree of damage of existing bridges. In this paper, the sensitivity of both static and dynamic behaviors of bridges are studied as a measure of damage assessment through experiments on model bridges induced with some specified artificial damages. And, a method of damage assessment of bridges based on those behaviors is discussed in detail. Finally, based on the results, a possible application for structural health monitoring systems for existing bridges is also discussed.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.