• Title/Summary/Keyword: Static pressure

Search Result 1,377, Processing Time 0.03 seconds

THE EFFECTS OF OCCLUSION ON THE STABILITY AFTER ORTHODONTIC TREATMENT (교정치료후 안정성에 미치는 교합의 영향)

  • Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.109-120
    • /
    • 1989
  • We tend to consider only static occlusion such as molar relationship, canine key, and interdigitation at finishing stage. Of course, this static occlusion is important for post-orthodontic stability. But we should remember that mandible is always on the move during its various functions. If no pressure or too much pressure is put on during its functions, untoward tooth movement could occur. And tooth mobility, periodontitis, wear facet, bruxism, and far worse temporomandibular disorder could occur. After many studies have been done on what is a desirable occlusal scheme to strengthen post-orthodontic stability, today, "mutually protective occlusion" is recommended. If an orthodontist does not have understanding about this occlusal scheme during orthodontic treatment, the following conditions will be resulted after orthodontic treatment. I. Centric discrepancy 1. centric prematurity 2. sunday bite 3. molar fulcrum II. Eccentric discrepancy 1. posterior interference 2. anterior interference If we have deep understanding about these discrepancies that can happen after orthodontic treatment and their causes, corrections, and especially preventions against them, post-orthodontic stability could be strengthened and further temporomandibular disorder could be prevented.

  • PDF

The Development of Turbo-Fan Blade for KTX (KTX용 터보팬 블레이드 개발)

  • Jang, Young-Min;Kwon, O-Woon;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.41-45
    • /
    • 2009
  • The new cooling fan for various parts & equipments of KTX is developed and evaluated to improve fan performance and durability. The characteristic curve of the developed fan is obtained according to KSB 6311 of performance test regulation. 70 degree of the installation angle of blade makes the fan to produce a maximum flow rate. This angle is found out through trial-error and is confirmed through the verification test. In order to improve the blade strength, the blade is produced by a draw forming. The adoption of AL50 reduces a fan weight by 6 kg. The new blade makes a static pressure 170 (mmAq), a discharge rate $140(m^3/min)$, a rotational speed 2886 (rpm) at the power 10 kw. which results 54% of the static pressure improvement relative to the original blade.

  • PDF

Three-Dimensional Numerical Simulation on a Circular-to-Rectangular Transition Duct (Circular-to-Rectangular Transition Duct 에서의 3차원 유동장에 관한 연구)

  • Cho Soo-Yong;Son Ho-Jae
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.55-61
    • /
    • 1998
  • The purpose of this study is to compare the predictive behaviors of the extended $k-{\varepsilon}$ turbulence model and the standard $k-{\varepsilon}$ turbulence model. Grid dependency is tested with the H-type grid and the O-type grid. Computations have been performed for a circular-to-rectangular transition duct. Numerical results for several sections along the streamwise have been obtained to compare with experimental results. The Reynolds number is 390,000 based on the bulk velocity at the inlet. The computed axial velocity contours, transverse velocity profiles, static pressure contours, peripheral skin friction coefficient, and peripheral wall static pressure distributions have been compared with experimental results. The computed results obtained with the extended $k-{\varepsilon}$ turbulence model show better agreement with experimental results than those obtained with the standard $k-{\varepsilon}$ turbulence model. Comparing to the computed results obtained with the H-type grid and O-type grid, those with H-type grid agree well with experimental results.

  • PDF

PERFORMANCE BY WIDTH CONTRACTION IN VANELESS DIFFUSER OF CENTRIFUGAL COMPRESSOR BY COMPUTATIONAL FLUID DYNAMICS (전산해석을 통한 원심압축기용 디퓨저의 폭변화에 따른 성능 연구)

  • Lee, S.C.;Lee, W.S.;Shin, Y.H.;Chung, J.T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.136-141
    • /
    • 2010
  • This study describes effects of width contraction in vaneless diffuser on the performance of centrifugal compressors using commercial CFD code. Numerical analysis for three different diffusers such as Parallel, half contraction, and full contraction was performed. The results show that the performance of the centrifugal compressor is improved through the use of the diffusers with width parallel in high flow rate. The width contraction of diffusers is influenced static pressure rises. Comparison with the experimental data shows agreement.

  • PDF

A Study on the Analysis of Seawater Pipeline Network for Open Rack Vaporizers (천연가스 기화기용 해수배관망 해석에 관한 연구)

  • Kim, Ho-Yeon;Park, Jong-Hark;Lee, Jeong-Hwan;Kim, Dong-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1760-1764
    • /
    • 2003
  • This study was carried out to establish an analytical method on the open circuit seawater pipeline network for open rack vaporizers(ORVs). The linear theory method was chosen to solve this network system. In particular, the method was modified to calculate the static pressure at each node and to determine the operating condition of each pump with the mean static pressure of pumps and ORVs. The proposed method is the first report demonstrating that can be used as a solver for the complicated open circuit. Also, the method indicated the importance for exactly calculating equivalent length of pipes including valves, bends, fittings, and others to raise the accuracy. Although this technique is good for solving this system, it is still required to improve the convergence rate.

  • PDF

Large Eddy Simulation on the Vorticity Characteristics of Three-Dimensional Small-Size Axial Fan with Different Operating Points (운전점에 따른 3차원 소형축류홴의 와도 특성에 대한 대규모 와 모사)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.64-70
    • /
    • 2016
  • The unsteady-state, incompressible and three-dimensional large-eddy simulation(LES) was carried out to evaluate the vorticity distribution of a small-size axial fan(SSAF). The X-component vorticity profiles developed around blade tips turn from axial to radial, and diminish the density of distribution according to the increase of static pressure. Otherwise, the Z-component vorticity profiles evenly develop at the region larger than the half radial distance of blade at the operating points of A and B, partly at the trailing-edge region of blade and radially over bellmouth according to the increase of static pressure.

Invention of Silencer for High Static Pressure Blower (고정압 블로어용 소음기개발)

  • Oh, Jin-Woo;Lee, Jang-Hyun;Lee, Kyu-Hyeong;Lee, Jung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.113-118
    • /
    • 2012
  • 본 논문은 실험적 방법을 통한 소음기의 개발과정 및 개발품의 성능평가에 대한 연구결과이다. 개발의 목적은 현재 적용된 외산 블로어 소음기의 국산화이며 이에 위해 적용 블로어의 허용 Spec.과 목표적감량 및 기 적용 소음기의 성능을 기준으로 개발 목표를 설정하였다. 또한 제작성을 고려한 내부 설계안을 선정, Shop Test를 실시하여 Test 결과에 따라 최적설계안을 확정하였다. 최종 개발품은 56mmAq의 정압손실과 23dB 이상의 소음저감효과를 가지고 있다.

  • PDF

Three-Dimensional Numerical Simulation within a Circular-to-Rectangular Transition Duct (Circular-to-Rectangular Transition Duct 내부의 3차원 유동장에 관한 연구)

  • Jo, Su-Yong;Jeong, Hui-Taek;Son, Ho-Jae
    • Journal of computational fluids engineering
    • /
    • v.3 no.2
    • /
    • pp.9-16
    • /
    • 1998
  • Predictive behaviors by the extended k-${\varepsilon}$ turbulence model and the standard k-${\varepsilon}$ turbulence model are compared. Grid dependency is tested with the H-type grid as well as the O-type grid. Computations have been performed on a circular-to-rectangular transition duct. The Reynolds number is 390,000 based on the bulk velocity at the inlet. The computed axial velocity contours, transverse velocity profiles, static pressure contours, peripheral skin friction coefficient, peripheral wall static pressure distributions and turbulence kinetic energy have been compared with experimental results. The computed results than those obtained with the standard k-${\varepsilon}$ turbulence model. Comparing to the computed results obtained with the H-type grid and O-type grid, those with H-type grid seem to agree well with experimental results.

  • PDF

Friction Torque Analysis of a Hydraulic Motor-Load System using Proportional Control Valve (비례제어밸브를 이용한 유압모터 부하계의 마찰토크 해석)

  • Yu, Hwan-Shin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.760-766
    • /
    • 2010
  • In this paper, The static friction torque and viscous friction torque including hydraulic motor-load system driven by hydraulic proportional control valve analysis. The basic experimental was performed toward characteristic in pressure and flow rate in hydraulic system energy. The variable of friction torque was experiment on brake pressure variable using pneumatic brake system. The analysis of nonlinear friction and linear friction was perform ed toward friction characteristic of hydraulic system.

Design of performance testing device for heat exhaust ventilation fan (제연용 송풍기의 방염성능 시험장치 설계)

  • Lee, Young-Mo;Kim, Kwang-Yong;Lee, Jae-Yup;Jung, Hyun-Jong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.367-372
    • /
    • 2005
  • This study primarily is concerned with a new device which has been developed following the international standards to measure the ventilation performance at elevated temperature. This device can measure duration of ventilation, performance of electricity, static pressure at elevated temperature and also it is having provision to measure reversible performances during fire hazards. Invented device is closed circuit type system which is best suited for korean industrial environment with low cost and high efficiency. International standards has been compared and performance testing has been major using BS 7346 which is tested by Warrington Fire Research Centre.

  • PDF