• Title/Summary/Keyword: Static pile

Search Result 236, Processing Time 0.029 seconds

The Pullout Behavior of a Large-diameter Batter ]Reaction Piles During Static Pile Load Test for a Large Diameter Socketed Pipe Pile (대구경 말뚝의 정재하시험시 대구경 경사반력말뚝의 인발거동)

  • 김상옥;성인출;박성철;정창규;최용규
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.1
    • /
    • pp.5-16
    • /
    • 2002
  • The pullout behavior of large-diameter steel pipe piles(diameter = 2,500mm, length = 38~40m), which were designed as compression piles but used as reaction piles during a static compression load test on a pile(diameter = 1,000m, length = 40m), was investigated. The steel pipe piles were driven by 20m into a marine deposit and weathered soil layer and then socketed by 10m into underlying weathered and soft rock layers. The sockets and pipe were filled with reinforced concrete. The steel pipe and concrete in the steel pipe zone and concrete and rebars in the socketed zone were fully instrumented to measure strains in each zone. The pullout deformations of the reaction pile heads were measured by LVDTs. Over the course of the study, a maximum uplift deformation of 7mm was measured in the heads of reaction piles when loaded to 10MN, and 1mm of residual uplift deflection was measured. In the reaction piles, about 83% and about 12% of the applied pullout loads were transferred in the weathered rock layer and in the soft rock layer, respectively. Also, at an uplift force of 10MN, shear stresses due to the uplift in the weathered rock layer md soft rock layer were developed as much as 125.3kPa and 61.8kPa, respectively. Thus, the weathered rock layer should be utilized as resisting layer in which frictional farce could be mobilized greatly.

End bearing Behavior of Open-ended Steel Pipe Piles Resting on Harden Cement Milk (시멘트밀크 고결체 위에 강관말뚝 선단 매입된 말뚝거동)

  • Park, Young-Ho;Kim, Sung-Hwan;Kim, Nag-Young;Kim, Hong-Jong;Park, Yong-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1140-1147
    • /
    • 2010
  • To find the soil plug of steel piles shaped by jet grouting, 4 blocks of cement milk with cube of 1.2m were made. 4 open-ended steel piles on the blocks were rested. The inner end part of 2 the piles was not reinforced. Cement milk 65%(SIG-1) and 100%(RJP-1) were filled into the block and height of 4.2 times of inner the pile diameter respectively. And the other the piles were welded 2 steel ring. The filling of the cement milk was an equal method as before(SIG-2 and RJP-2). Also the strain gauges were installed and the static pile load tests were done at the piles all. As a result, list in great order for effect of soil plug was (1)SIG-1, (2)SIG-2, (3)RJP-1, (4)RJP-2. This is because of strength and filling height of cement milk. And the higher the strength is, the greater the confining coefficient is.

  • PDF

Bearing Capacity of Mid & Small dia Hellical Pile (중·소구경 헬리컬 파일의 지지력 특성)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.75-86
    • /
    • 2020
  • As the urban regeneration project and the old housing maintenance project are actively progressing in Korea, small-scale building construction is being carried out in downtown areas. Small buildings in the downtown area are constructed on about 4 to 10 floors, and since they are carried out in small units in residential areas, it is difficult to enter large equipment to construct existing piles, and it is more vulnerable to complaints about noise and vibration. in this study, helical piles suitable for urban areas or small sites where it is difficult to enter large equipment, such as noise and vibration. Reliability analysis was performed on the results of the static load tests and dynamic load tests conducted at the LH site and the bearing capacity calculated by the hydrostatic method and the empirical formula (N value). As a result of comparing and analyzing the design formula and the results of static load test and dynamic load tests, the correlation between the design formula of the bored pile (Road bridge design standard) formula using N value and the design formula by the modified Davisson method frequently used by method commonly European helical file practitioners.

Analysis on Behavior of Vertically Loaded Single Pile included in Pile Group (무리말뚝을 구성하는 외말뚝의 연직방향 하중지지 거동분석)

  • Lee, Seung-Hyun;Kim, Byoung-Il;Yoo, Wan-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4863-4868
    • /
    • 2012
  • Static pile load tests were conducted on the two piles which comprised group pile installed in sand and the test results were compared with those obtained from load transfer method. Predicted load bearing capacity of the pile which locates center portion of the group pile was less than that from the load test and the reason is thought to be the densification of the soil due to the installation of the group pile. Predicted pile capacity of the API method, Coyle and Sulaiman method were 77%, 90% of the bearing capacity obtained from the load test, respectively. Comparing ultimate bearing capacities of the pile locating at the edge of the group pile, those predicted by the API method, Coyle and Sulaiman method were 1.1 times, 1.3 times of the bearing capacity obtained from the pile load test, respectively.

Study on the Improvement of Response Spectrum Analysis of Pile-supported Wharf with Virtual Fixed Point (가상고정점기법이 적용된 잔교식 구조물의 응답스펙트 럼해석법 개선사항 도출 연구)

  • Yun, Jung Won;Han, Jin Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.311-322
    • /
    • 2018
  • As a method of seismic-design for pile-supported wharves, equivalent static analysis, response spectrum analysis, and time history analysis method are applied. Among them, the response spectrum analysis is widely used to obtain the maximum response of a structure. Because the ground is not modeled in the response spectrum analysis of pile-supported wharves, the amplified input ground acceleration should be calculated by ground classification or seismic response analysis. However, it is difficult to calculate the input ground acceleration through ground classification because the pile-supported wharf is build on inclined ground, the methods to calculate the input ground acceleration proposed in the standards are different. Therefore, in this study, the dynamic centrifuge model tests and the response spectrum analysis were carried out to calculate the appropriate input ground acceleration. The pile moment in response spectrum analysis and the dynamic centrifuge model tests were compared. As a result of comparison, it was shown that the response spectrum analysis results using the amplified acceleration in the ground surface were appropriate.

Advancement in Design Criteria of Helical Pile (헬리컬 파일 설계식 고도화 연구)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.87-96
    • /
    • 2021
  • Korea has begun to use the Helical pile prevalent in Europe. Korea hasn't still set up the standard design criteria on Helical pile due to the lack of relevant researches. In this regard, this study carried out static and dynamic load tests on Helical pile and then performed reliability analysis including the previous research data. The results present that Road bridge design standard design criteia for pre-boring pile with regard to Modified Davisson method showed good reliability and consistency because Resistance bias factor of this design criteria approached '1.0' and Design C.O.V. showed 'low' level.

Wind-induced responses of supertall buildings considering soil-structure interaction

  • Huang, Yajun;Gu, Ming
    • Wind and Structures
    • /
    • v.27 no.4
    • /
    • pp.223-234
    • /
    • 2018
  • In this study, a simplified three-dimensional calculation model is developed for the dynamic analysis of soil-pile group-supertall building systems excited by wind loads using the substructure method. Wind loads acting on a 300-m building in different wind directions and terrain conditions are obtained from synchronous pressure measurements conducted in a wind tunnel. The effects of soil-structure interaction (SSI) on the first natural frequency, wind-induced static displacement, root mean square (RMS) of displacement, and RMS of acceleration at the top of supertall buildings are analyzed. The findings demonstrate that with decreasing soil shear wave velocity, the first natural frequency decreases and the static displacement, RMS of displacement and RMS of acceleration increase. In addition, as soil material damping decreases, the RMS of displacement and the RMS of acceleration increase.

Bearing Capacity of In-situ Cast Piles in Weak Sedimentary Rocks (미고결 퇴적암층에서의 현장타설말뚝 지지력 특성 연구)

  • Sim, Dong-Hyun;Kim, Ki-Seop;Yu, Seok-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.100-109
    • /
    • 2004
  • Is this study, results of static pile load tests of in-situ cast piles in weak or uncemented sedimentary rock layers have been analyzed and presented. Consdierations on the characteristics of soils sedimentary rocks have been made. From the measurements of strain gauges and extensometers the relationship of unit skim friction versus displacement and that of unit end bearing versus displacement have been obatined to verity the characteristics of bearing capacity of this uncemented sedimentary rock layers. Also, a comparison has been made between ultimate skin friction in compression and tension.

  • PDF

Static Behavior of Hollow Cantilever Beam using Multiplexed FBG Sensors (다중화된 FBG 센서를 이용한 중공 내민보의 정적 거동 분석)

  • Lee, Tae-Hee;Kang, Dong-Hoon;Chung, Won-Seok;Mok, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.593-598
    • /
    • 2009
  • This paper presents a preliminary study to monitor the lateral behavior of pile foundation using multiplexed fiber Bragg grating (FBG) sensors. In the preliminary study, an 1.7 meter long cantilever beam with the shape of square hollow box was fabricated and tested under the static loading. Four FBG sensors were multiplexed in a single optical fiber and installed into the top and bottom of the cantilever beam. The strains are directly measured from FBG sensors followed by curvature calculations based on the plane section assumption. Vertical deflections are then estimated using the regression analyses based on the geometric relationships. It has been found that excellent correlation with conventional sensing system was observed. The success of the test encourages the use of the FBG sensing system as a monitoring system for pile foundations. However, further consideration should be given in the case of the sensor malfunction for the practical purpose.

  • PDF

Estimation of Lateral Dynamic P-multiplier of Group Pile Using Dynamic Numerical Analysis Results (동적 수치해석 결과를 이용한 군말뚝의 횡방향 동적 P-승수 산정)

  • Park, Jeong-Sik;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.567-578
    • /
    • 2018
  • In this study, to investigate the effect of the stress reduction of group piles by dynamic loading, a dynamic p-y curve was established and the dynamic p-multiplier was calculated. Dynamic numerical analysis was performed by input sinusoidal waves to the bottom of the pile - ground system for $2{\times}2$ group pile, single pile and $5{\times}5$ group pile, single pile in dry sandy soil, and the pile spacing was changed to 2.5 and 5.0 times of the pile diameter. By establishing and comparing the dynamic p-y curves of the single pile and group piles, the dynamic group pile effect of the piles according to the pile center spacing and row position of the group pile piles is analyzed. $5{\times}5$ showed symmetry of the dynamic P-multiplier value around the pile origin coordinate. The dynamic p-multiplier value at the single pile, $5{\times}5$ pile (pile spacing: 2.5D) is 0.26 ~ 0.30 at the pile number 3, pile number 23, 0.14 pile number 13, and 0.14 ~ 0.38 at the pile number 5, pile number 18. These values differed from the static p-multiplier, especially due to the different loading conditions. The dynamic p-multiplier ($P_{dm}$) estimation through various types of input dynamic loads is expected to be used for dynamic design and analysis of group pile-ground systems of civil foundation structures.