Browse > Article

The Pullout Behavior of a Large-diameter Batter ]Reaction Piles During Static Pile Load Test for a Large Diameter Socketed Pipe Pile  

김상옥 (현대건설 중앙하수처리장)
성인출 (경성대학교 대학원 토목공학과)
박성철 (경성대학교 대학원 토목공학과)
정창규 (부산광역시 건설본부)
최용규 (경성대학교 건설·환경공학부)
Publication Information
Journal of the Korean Geotechnical Society / v.18, no.1, 2002 , pp. 5-16 More about this Journal
Abstract
The pullout behavior of large-diameter steel pipe piles(diameter = 2,500mm, length = 38~40m), which were designed as compression piles but used as reaction piles during a static compression load test on a pile(diameter = 1,000m, length = 40m), was investigated. The steel pipe piles were driven by 20m into a marine deposit and weathered soil layer and then socketed by 10m into underlying weathered and soft rock layers. The sockets and pipe were filled with reinforced concrete. The steel pipe and concrete in the steel pipe zone and concrete and rebars in the socketed zone were fully instrumented to measure strains in each zone. The pullout deformations of the reaction pile heads were measured by LVDTs. Over the course of the study, a maximum uplift deformation of 7mm was measured in the heads of reaction piles when loaded to 10MN, and 1mm of residual uplift deflection was measured. In the reaction piles, about 83% and about 12% of the applied pullout loads were transferred in the weathered rock layer and in the soft rock layer, respectively. Also, at an uplift force of 10MN, shear stresses due to the uplift in the weathered rock layer md soft rock layer were developed as much as 125.3kPa and 61.8kPa, respectively. Thus, the weathered rock layer should be utilized as resisting layer in which frictional farce could be mobilized greatly.
Keywords
Frictional force; Instrumented pile; Large-diameter batter reaction piles; Large diameter socketed pipe piles; Pullout deformation; Static pullout pile load test; Weathered rock layer;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Standard Test Method for Piles Under Static Axial Compressive Load /
[] / ASTM D1143-81
2 광안대로 건설공사의 대구경 말뚝 정재하시험과 수치해석을 통한 말뚝 기초의 안정성 검토 보고서 /
[ 최용규 ] / 경성대학교 지반공학연구 보고서 Report No. KSU/GT-00-1
3 Applications of Large - Diameter Bored Piles in the United States, Deep Foundations on Bored and Auger piles /
[ O'Neill, M. W. ] / Proc. of the 3rd International Geotechnical seminar on Bored and Auger piles
4 /
[ Dunnicliff, J. ] / Geotechnical Instrumentation for Monitoring Field Performance
5 /
[ Reese, L.C.;O'Neill, M.W. ] / Drilled Shafts: Construction and Design
6 Static and Cyclic Axial Load Tests on Two 762 mm Diameter Pipe 'Piles in Clays, Large - scale pile tests in clay /
[ Cox, W.R.;Cameron, H.K.;Clarke, J. ] / Proc. of the conference recent large - scale fully instrumented pile tests in clay held at the Institution of Civil Engineers
7 Standard Test Method for Individual Piles Under Static Axial Tensile Load /
[] / ASTM D3689-90
8 New Design Method for Drilled Shafts from Common Soil and Rock Tests /
[ Reese, L. C.;O'Neill, M. W. ] / Proceedings, Foundation Engineering: Current Principles and Practices
9 Elastometer-200을 이용한 부산지역 해저 지반의 지반특성치 평가 /
[ 김동철;최용규 ] / 한국지반공학회 논문집   과학기술학회마을