• Title/Summary/Keyword: Static inverter

Search Result 159, Processing Time 0.037 seconds

Harmonic Optimization Techniques in Multi-Level Voltage-Source Inverter with Unequal DC Sources

  • Aghdam, M. Ghasem Hosseini;Fathi, S. Hamid;Gharehpetian, Gevorg B.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • One of the major problems in electric power quality is the harmonic contents. There are several methods of indicating the quantity of harmonic contents. The most widely used measure is the total harmonic distortion (THD). Various switching techniques have been used in static converters to reduce the output harmonic content. This paper presents and compares the two harmonic optimization techniques, known as optimal minimization of the total harmonic distortion (OMTHD) technique and optimized harmonic stepped-waveform (OHSW) technique used in multi-level inverters with unequal dc sources. Both techniques are very effective and efficient for improving the quality of the inverter output voltage. First, we describe briefly the cascaded H-bridge multi-level inverter structure. Then, we present the switching algorithm for the inverter based on OHSW and OMTHD techniques. Finally, the results obtained for the two techniques are analyzed and compared. The results verify the effectiveness of the both techniques in multi-level voltage-source inverter with non-equal dc sources, clarifying the advantages of each technique.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.

A Study on Optimized PWM Strategy to Improve Output Voltage Quality of HEP System Boarded on 8200 Series Electric Locomotives (8200호대 전기기관차 객차전원공급장치(HEP)의 출력전압품질향상을 위한 최적화된 PWM 방법)

  • Lee, Eul-Jae;Lee, Jin-Kook;Youn, Cha-Joong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1628-1632
    • /
    • 2013
  • HEP(Head Electric Power) system, supplying 3-phase service power to the coach vehicles, is a kind of special auxiliary power equipment which is boarded on 8200 series electric locomotives in KORAIL. This equipment shares high voltage DC link with a main propulsion converter/inverter systems. It was difficult to use high frequency PWM technique so that GTO has been used as a power device same like the main power system. Due to low PWM frequency(300Hz) of HEP inverter, the output voltage has less power quality comparing to normal SIV(Static Inverter) system. In this paper, an optimal PWM strategy is presented for new IGBT type HEP inverter system. Several PWM techniques were investigated to improve output voltage quality under fixed lower filter inductance and not high PWM frequency. Finally PC simulations have been done to clarify its availability.

Design and Control of Braking Chopper Circuit for Ventilation Inverter of Traction Control System (고속전철용 추진제어장치의 냉각용 인버터를 위한 제동초퍼 회로 설계 및 제어)

  • Cho, Sung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.314-315
    • /
    • 2011
  • This paper introduces the design and control method of braking chopper circuit which can supply input power to ventilation inverter of traction control system. The DC input voltage from auxiliary block (static inverter) is normally used as an input of ventilation inverter. It converts DC input to AC output voltage to drive cooling fans for traction control system and traction motors. The electrical braking force is very important for high speed train to guarantee safety even though the train is running in the dead section where the pantograph voltage is not supplied. When the high speed train decelerate speed in dead section, the regenerative energy is dissipated by braking resistor. This paper proposed the braking chopper control method to implement rheostatic braking function and the appropriate chopper circuit for supplying voltage source to ventilation inverter during rheostatic braking mode. The proposed chopper circuit makes it possible for traction control system to regenerate power continuously regardless of the existence of pantograph voltage. The feasibility of proposed braking chopper control and circuit were proven by inertia load test and actual train field test.

  • PDF

An Optimal Damping Control Algorithm of Direct Two-level Inverter for Miniaturization and Weight Reduction of Auxiliary Power Supply on Railway Vehicle

  • Lee, Chang-hee;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2335-2343
    • /
    • 2018
  • This paper proposes an optimal damping control algorithm of the DTI (Direct Two-level Inverter) to miniaturize and reduce the weight of auxiliary power supply for railway vehicles. The conventional auxiliary power supply for railway vehicles uses a DC-DC converter to maintain the inverter input power from the line voltage smoothly. The proposed topology does not use a DC-DC converter for reducing of manufacturing and maintenance costs. It also proposes a DTI topology removed damping resistors that generate ground signal noise in a certain period. At this time, a resonance phenomenon of DC-link voltage occurs due to variation of the inductive load, and a method of controlling the resonance phenomenon of DC-link voltage is required. In order to suppress the resonance phenomenon of the DC-link voltage, at a point before resonance occurs, this paper introduces an algorithm to suppress the resonance phenomenon of DC-link voltage by compensating the resonance component of the q axis voltage of the synchronous reference frame. The proposed algorithm verifies the effect through simulation and experiment.

A Study On Field Test of IGBT Type Propulsion System fo Electric oilway (전동차용 IGBT형 추진제어장치의 본선시험에 관한 연구)

  • 정만규;고영철;방이석;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.515-521
    • /
    • 2000
  • This paper describes the field test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T and the electrical equipment for field test are as follows : VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with 1C4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

Advanced Static Over-modulation Scheme using Offset Voltages Injection for Simple Implementation and Less Harmonics

  • Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.138-145
    • /
    • 2015
  • In this paper, a novel static overmodulation scheme (OVM) for space-vector PWM (SVPWM) is proposed. The proposed static OVM scheme uses the concept of adding offset voltages in linear region as well as overmodulation region to fully utilize DC-link voltage. By employing zero sequence voltage injection, the proposed scheme reduces procedures for achieving SVPWM such as complicated gating time calculation. In addition, this paper proposes a stepwise discontinuous angle movement in high modulation region in order to reduce Total Harmonic Distortion (THD). The validity of the proposed scheme is verified through theoretical analysis and experimental results.

Static Characteristic and Dynamic Characteristic Experiment of First-stage Proportional Pressure Control Valve (1단 비례 압력제어밸브의 정특성 및 동특성 실험)

  • Jeong, Heon-Sul;Nam, Ji-Woo;Lim, Hyo-Joon;Jung, Seung-Wook;Han, Sung-Min
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.18-24
    • /
    • 2010
  • Because of the increasing demand on the high precision and high response of a machinery, electronic control valves are widely adopted at various application fields. This paper studies on the static characteristic of a first-stage proportional pressure control valve. At first an experimental apparatus including hyd. pump variable speed inverter, pressure and data aquisition system was setted up with the experimental apparatus, various tests such as P-Q-W test, hyd, pump, dynamic, static, frequency response test of the proportional valve was carride out and the results are discussed.

  • PDF

Single phase induction motor driving system using auxiliary resonant DC-DC converter (보조 공진 DC-DC컨버터를 이용한 단상 유도 전동기 구동 시스템)

  • Lee, S.H.;Mun, S.P.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1190-1192
    • /
    • 2002
  • These days, electromagnetic radiation noise and switching losses of static converter become harmful. Many resonant inverters with radiation techniques solve their such problems. Auxiliary Resonant Commutated Pole Inverter (ARCP) was proposed. but it has two demerits. In circuit configuration. It isn't constructed by 2 in 1 IGET modules. Besides, control is complicated because of neutral point voltage control and boost current control. This paper proposes a new auxiliary resonant inverter which solved two demerits. In addition, it deals efficiency which compared with hard switching inverter and result of separation of power loss

  • PDF

Design and Research on High-Reliability HPEBB Used in Cascaded DSTATCOM

  • Yang, Kun;Wang, Yue;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.830-840
    • /
    • 2015
  • The H-bridge inverter is the fundamental power cell of the cascaded distribution static synchronous compensator (DSTATCOM). Thus, cell reliability is important to the compensation performance and stability of the overall system. The concept of the power electronics building block (PEBB) is an ideal solution for the power cell design. In this paper, an H-bridge inverter-based “plug and play” HPEBB is introduced into the main circuit and the controller to improve the compensation performance and reliability of the device. The section that discusses the main circuit primarily emphasizes the design of electrical parameters, physical structure, and thermal dissipation. The section that presents the controller part focuses on the principle of complex programmable logic device -based universal controller This section also analyzes typical reliability and anti-interference issues. The function and reliability of HPEBB are verified by experiments that are conducted on an HPEBB test-bed and on a 10 kV/± 10 Mvar DSTATCOM industrial prototype.