Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Kinetic Investigation of CO2-CH4 Reaction over Ni/La2O3 Catalyst using Photoacoustic Spectroscopy

  • Oh, Hyun-Jin;Kang, Jin-Gyu;Heo, Eil;Lee, Sung-Han;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2615-2620
    • /
    • 2014
  • Ni/$La_2O_3$ with a high dispersion was prepared by reduction of $La_2O_3$ perovskite oxide to examine the catalytic activity for the $CO_2-CH_4$ reaction. The Ni/$La_2O_3$ catalyst was found to be highly active for the reaction. The ratios of $H_2$/CO were measured in a flow of the reaction mixture containing $CO_2/CH_4$/Ar using an on-line gas chromatography system operated at 1 atm and found to be varied with temperature between 0.66 and 1 in the temperature range of $500-800^{\circ}C$. A kinetic study of the catalytic reaction was performed in a static reactor at 40 Torr total pressure of $CO_2/CH_4/N_2$ by using a photoacoustic spectroscopy technique. The $CO_2$ photoacoustic signal varying with the concentration of $CO_2$ during the catalytic reaction was recorded as a function of time. Rates of $CO_2$ disappearance in the temperature range of $550-700^{\circ}C$ were obtained from the changes in the $CO_2$ photoacoustic signal at early reaction stage. The plot of ln rate vs. 1/T showed linear lines below and above $610^{\circ}C$. Apparent activation energies were determined to be 10.4 kcal/mol in the temperature range of $550-610^{\circ}C$ and 14.6 kcal/mol in the temperature range of $610-700^{\circ}C$. From the initial rates measured at $640^{\circ}C$ under various partial pressures of $CO_2$ and $CH_4$, the reaction orders were determined to be 0.43 with respect to $CO_2$ and 0.33 with respect to $CH_4$. The kinetic results were compared with those reported previously and used to infer a reaction mechanism for the Ni/$La_2O_3$-catalyzed $CO_2-CH_4$ reaction.

The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process (반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화)

  • Lee Sang-Ho;Lee Seung-Ho;Kim Kyu-Chae;Kwon Tae-Young;Park Jin-Goo;Bae So-Ik;Lee Gun-Ho;Kim In-Jung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

Effect of Cooling Fan on Domestic Small Diesel Engine (소형(小型)디젤기관(機關)의 냉각(冷却)홴의 성능(性能)에 관(關)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.19 no.1
    • /
    • pp.97-102
    • /
    • 1992
  • As engine is produced with foreign technology, basic data for cooling fan are very few in korea. Therefore, an experiment was performed to obtain data on cooling fans for the cooling system. The results obtained are summarized as follows: 1. Efficiency of cooling fan was 49.9% while the engine eras running at the rated power. 2. Shaft power of the fan was 0.5 kW maximum at the rated power. 3. Air flow rate of the fan was $12.9m^3/min$. at the rated power. 4. Static pressure of the fan was 29.8 mmHg at the rated power.

  • PDF

A Study on The Investment of The Secondhand BulkShip Using Real Option Model (실물옵션을 활용한 중고선박 가치평가연구)

  • Lee, Chong-Woo;Jang, Chul-Ho;Choi, Jung-Suk
    • Journal of Korea Port Economic Association
    • /
    • v.38 no.2
    • /
    • pp.95-107
    • /
    • 2022
  • Shipping companies earn profits through cargo transportation, and therefore, investment decisions to purchase ships are more important than anything else. Nevertheless, the cash flow discount method was mainly used in the economic analysis method, which assumes that all situations are static. This study shows that the real option model is useful in the economic analysis of ship investment. This economic analysis took into account the irreversibility of investment and uncertainty of benefits. In particular, this study used a binary option price determination model among real options. In addition, the simulation was conducted using actual investment data of A shipping company. As a result of the analysis, the investment value of used ships according to the net present value method was analyzed as negative (-), but the investment value in the real option model reflecting the flexibility of decision-making was evaluated as having positive (+) economic feasibility. It was analyzed that economic feasibility is affected by profit volatility and discount rate. Therefore, this study is expected to help shipping companies make more flexible decisions by using the real option model along with the existing net present value method when making ship investment decisions.

Effects of streambed geomorphology on nitrous oxide flux are influenced by carbon availability (하상 미지형에 따른 N2O 발생량 변화 효과에 대한 탄소 가용성의 영향)

  • Ko, Jongmin;Kim, Youngsun;Ji, Un;Kang, Hojeong
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.11
    • /
    • pp.917-929
    • /
    • 2019
  • Denitrification in streams is of great importance because it is essential for amelioration of water quality and accurate estimation of $N_2O$ budgets. Denitrification is a major biological source or sink of $N_2O$, an important greenhouse gas, which is a multi-step respiratory process that converts nitrate ($NO_3{^-}$) to gaseous forms of nitrogen ($N_2$ or $N_2O$). In aquatic ecosystems, the complex interactions of water flooding condition, substrate supply, hydrodynamic and biogeochemical properties modulate the extent of multi-step reactions required for $N_2O$ flux. Although water flow in streambed and residence time affect reaction output, effects of a complex interaction of hydrodynamic, geomorphology and biogeochemical controls on the magnitude of denitrification in streams are still illusive. In this work, we built a two-dimensional water flow channel and measured $N_2O$ flux from channel sediment with different bed geomorphology by using static closed chambers. Two independent experiments were conducted with identical flume and geomorphology but sediment with differences in dissolved organic carbon (DOC). The experiment flume was a circulation channel through which the effluent flows back, and the size of it was $37m{\times}1.2m{\times}1m$. Five days before the experiment began, urea fertilizer (46% N) was added to sediment with the rate of $0.5kg\;N/m^2$. A sand dune (1 m length and 0.15 m height) was made at the middle of channel to simulate variations in microtopography. In high- DOC experiment, $N_2O$ flux increases in the direction of flow, while the highest flux ($14.6{\pm}8.40{\mu}g\;N_2O-N/m^2\;hr$) was measured in the slope on the back side of the sand dune. followed by decreases afterward. In contrast, low DOC sediment did not show the geomorphological variations. We found that even though topographic variation influenced $N_2O$ flux and chemical properties, this effect is highly constrained by carbon availability.

Evaluation of Embolization Effect of Hepatocellular Carcinoma by Hepatic Arterial Flow Study with $^{99m}Tc$-MAA SPECT (간암에서 색전술의 효과를 평가하는데 있어서 $^{99m}Tc$-MAA SPECT를 이용한 간동맥 혈류 검사의 의의)

  • Lee, Byung-Hee;Yoo, Hyung-Sik;Lee, Jong-Doo;Chung, Jin-Ill;Park, Chang-Yun;Lee, Jong-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.62-68
    • /
    • 1994
  • This study was aimed to compare the density of the functional microcirculation of hepatocellular carcinoma (HCC) with normal liver and to investigate the effect of hepatic-arterial oily chemoembolization (HAE) by radionuclide examination. Methods : Eight patients with HCC proven by biopsy in five, and clinically and radiologically in three were included. The mixture of 2 cc normal saline with three to four mCi of $^{99m}Tc$-MAA was infused through a hepatic-arterial catheter for a minute. Dynamic images were obtained at a rate of 4 sec per frame for a minute, and static images and SPECT were followed. Results : In three patients who underwent hepatic arterial angiography (HAA) alone, radioactivity was markedly increased in tumors compared to the adjacent liver immediately after infusion of $^{99m}Tc$-MAA. The ratios of tumoral and extratumoral up-take (T/E ratio) were above 6.5 (range; $6.5{\sim}l9$, mean; 12.5). In four of the five patients who under-went superselective HAE, T/E ratio were remark-ably decreased ($0.5{\sim}1.3$). The areas of embolization were better delineated in radionuclide study than in postembolization HAA. In the other one who was considered to be embolized completely on HAA, strong radiouptake in the tumor was disclosed (T/E ratio; 7.0). Conclusions : Therefore hepatic-arterial flow study with radionuclide imaging using $^{99m}Tc$-MAA can be a valuable method to assess the accurate embolization effect in HCC.

  • PDF

Rectal Temperature Maintenance Using a Heat Exchanger of Cardioplegic System in Cardiopulmonary Bypass Model for Rats (쥐 심폐바이패스 모델에서 심정지액 주입용 열교환기를 이용한 직장체온 유지)

  • Choi Se-Hoon;Kim Hwa-Ryong;Paik In-Hyuck;Moon Hyun-Jong;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.505-510
    • /
    • 2006
  • Background: Small animal cardiopulmonary bypass (CPB) model would be a valuable tool for investigating path-ophysiological and therapeutic strategies on bypass. The main advantages of a small animal model include the reduced cost and time, and the fact that it does not require a full scale operating environment. However the rat CPB models have a number of technical limitations. Effective maintenance and control of core temperature by a heat exchanger is among them. The purpose of this study is to confirm the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. Material and Method: The miniature circuit consisted of a reservoir, heat exchanger, membrane oxygenator, roller pump, and static priming volume was 40 cc, Ten male Sprague-Dawley rats (mean weight 530 gram) were divided into two groups, and heat exchanger (HE) group was subjected to CPB with HE from a cardioplegia system, and control group was subjected to CPB with warm water circulating around the reservoir. Partial CPB was conducted at a flow rate of 40 mg/kg/min for 20 min after venous cannulation (via the internal juglar vein) and arterial cannulation (via the femoral artery). Rectal temperature were measured after anesthetic induction, a ter cannulation, 5, 10, 15, 20 min after CPB. Arterial blood gas with hematocrit was also analysed, 5 and 15 min after CPB. Result: Rectal temperature change differed between the two groups (p<0.01). The temperatures of HE group were well maintained during CPB, whereas control group was under progressive hypothermia, Rectal temperature 20 min after CPB was $36.16{\pm}0.32^{\circ}C$ in the HE group and $34.22{\pm}0.36^{\circ}C$ in the control group. Conclusion: We confirmed the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. This model would be a valuable tool for further use in hypothermic CPB experiment in rats.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF