• Title/Summary/Keyword: Static Ram

Search Result 58, Processing Time 0.023 seconds

Case Study of Comparative Analysis between Static and Dynamic Loading Test of PHC Pile (굴착 후 타입된 PHC 말뚝의 재하시험 결과 비교분석 사례 연구)

  • Kim, Jaehong;Yea, Geuguwen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.13-23
    • /
    • 2013
  • In the west coastal soft ground, the static and dynamic loading tests for PHC piles which were executed using light driving without injecting cement milk were carried out and the correlation was analyzed. Initial dynamic loading test used hydraulic hammer(ram weight 70kN) and final average penetration effect presented 3.0 to 8.0mm at 0.8m drop. Then final allowable bearing capacity using CAPWAP presented 776.4 to 1,053.6kN a pile. The static loading tests which were performed at the other piles loaded 200% of the design load dividing by eight phases. As the result, total settlement was 15.97 to 16.38mm and residual settlement was 4.48 to 5.38mm, but both yielding and ultimate load can't be estimated. Therefore, allowable bearing capacity was determined larger than 1,200kN a pile regarding maximum test load as yielding load. Thus, it showed that allowable bearing capacity of the dynamic loading test was larger than static loading test in 1.54 to 1.14 times.

세계 3번째로 SRAM시대열어 - 256KD 램 보다 고부가가치 8월부터 생산수출

  • 한국발명진흥회
    • 발명특허
    • /
    • v.10 no.8 s.114
    • /
    • pp.64-64
    • /
    • 1985
  • 금성반도체(대표 : 구자두)는 미국, 일본에 이어 세계 3번째로 첨단반도체제품인 CMOS 64K SRAM을 자체개발하는데 성공했다. 국내 최초로 개발된 금성반도체의 CMOS 64K SRAM은 우리나라의 반도체 기술수준을 선진국 수준으로 성큼 다가서게 했다. CMOS 64K SRAM은 NMOS의 256K DRAM에 비해 작동속도가 2배이상 빠를 뿐만 아니라 재충전이 필요없는 완전한 스태틱(static) RAM으로 대용량$\cdot$고속$\cdot$고신뢰성을 요하는 고성능 컴퓨터, 통신장비등 첨단 산업용 기기의 기억장치에 주로 사용된다.

  • PDF

Introduction to HILO-3 Logic Simulator

  • Jang, Deok-Ho;Kim, Yong-Ju;Gwak, Myeong-Sin;Lee, Cheol-Dong;Yu, Yeong-Uk
    • ETRI Journal
    • /
    • v.8 no.1
    • /
    • pp.44-52
    • /
    • 1986
  • The main features of HILO-3 logic simulator are introduced. It is regarded as one of the most powerful logic simulator available now in electronic industry. The major functions and concepts are reviewed with some examples; circuit description using HDL (Hardware Description Language), waveform description using WDL (Waveform Description Language) and fault-free simulation for static RAM circuit. This program is expected to help the system designers, integrated circuit designers and test engineers.

  • PDF

Design Optimization of the Rib Structure of a 5-Axis Multi-functional Machine Tool Considering Static Stiffness (정강성을 고려한 5축 복합가공기의 리브 구조 최적설계)

  • Kim, Seung-Gi;Kim, Ji-Hoon;Kim, Se-Ho;Youn, Jae-Woong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.313-320
    • /
    • 2016
  • The need for high-strength, multi-axis, and multi-functional machine tools has recently increased because of part complexity and workpiece strength. However, most of the machine tool manufacturers rely on experience for a detailed design because of the shortcomings in the existing design technology. This study uses a topology optimization method to more effectively design a large multi-functional machine tool considering static stiffness. The ram, saddle, and column parts are important structures in a machine tool. Hence, they are selected for the finite element method analysis. Based on this analysis, the optimized internal rib structure for those parts is designed for desirable rigidity and weight. This structure could possibly provide the required design technology for machine tool manufacturers.

The Influence of Eye Movement Program Applied to Elderly People on Static Balance (안구운동 프로그램 적용이 노인의 정적 균형에 미치는 영향)

  • Park, Jong-Hang;Kang, Bo-Ram;Kim, Yoon-Hwan;Kim, Jang-Ju;Son, Kyung-Hyun;Song, Hyun-Seung;Kim, Tae-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.11-17
    • /
    • 2011
  • Background: To evaluate the influences of Eye movement program applied to elderly people on static balance. Methods: The subjects consisted of fourteen elderly people. The subjects were divided into two group. The control group (n=7) received no exercise and/or stimulation. The Eye movement program training (E/P) group (n=7) performed balance training using word card and batom. E/P group were accomplished during 4weeks (5 day/week, 60 min/day). All tests were completed before and after experiment. The static balance ability was measured by normal standing when eye open and close on good balance system, respectively. For each case, the experimental data were obtained in 3 item; mean X speed, mean Y speed and velocity moment. Results: The result of this study were as follows: 1. In E/P group, the statistically significants were shown on only mean Y speed in the case of normal standing when eye open (p<.05), but the statistically significants were not shown on mean X, Y speed and velocity moment in the case of normal standing when eye close (p>.05). 2. In control group, the statistically significants were not shown on all posture (p>.05). 3. There was a statistically significant difference on the mean Y speed and velocity moment in the case of normal standing when eye open between control group and E/P group (p<.05). Conclusions: The above results revealed that balance training using Eye movement program were partly effective for improving the static balance ability.

  • PDF

Construction of Multichannel Analyser with Successive Approximation Type ADC (방사선 에너지 분석을 위한 MCA시스템 제작에 관한 연구)

  • Yook, Chong-Chul;Oh, Byung-Hoon;Kim, Young-Gyoon
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.12-25
    • /
    • 1987
  • A basic multichannel analyser (MCA) system have been designed and constructed with the successive approximation type ADC (Analog to Digital Converter). Linear Gate, window, and palse stretcher consist of mainly linear and logic IC's, and are properly combined together to achieve short dead time and good linearity of the system. ADC 1211 (analysing time: $120{\mu}sec$) and S-RAM (static random acess memory) 6264 are used in ADC module. Two 6264 memories are connected in parallel in order to-provide enough counting capacity ($2^{16}-1$). Interfaced microcomputer Apple II controls this system and analizes the counted data. The system is tested by input pulses between 0V to 10V from oscillator.

  • PDF

A 3-D Vision Sensor Implementation on Multiple DSPs TMS320C31 (다중 TMS320C31 DSP를 사용한 3-D 비젼센서 Implementation)

  • Oksenhendler, V.;Bensrhair, Abdelaziz;Miche, Pierre;Lee, Sang-Goog
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.124-130
    • /
    • 1998
  • High-speed 3D vision systems are essential for autonomous robot or vehicle control applications. In our study, a stereo vision process has been developed. It consists of three steps : extraction of edges in right and left images, matching corresponding edges and calculation of the 3D map. This process is implemented in a VME 150/40 Imaging Technology vision system. It is a modular system composed by a display, an acquisition, a four Mbytes image frame memory, and three computational cards. Programmable accelerator computational modules are running at 40 MHz and are based on TMS320C31 DSP with a $64{\times}32$ bit instruction cache and two $1024{\times}32$ bit internal RAMs. Each is equipped with 512 Kbytes static RAM, 4 Mbytes image memory, 1 Mbytes flash EEPROM and a serial port. Data transfers and communications between modules are provided by three 8 bit global video bus, and three local configurable pipeline 8 bit video bus. The VME bus is dedicated to system management. Tasks between DSPs are distributed as follows: two DSPs are used to edges detection, one for the right image and the other for the left one. The last processor computes the matching process and the 3D calculation. With $512{\times}512$ pixels images, this sensor generates dense 3D maps at a rate of about 1 Hz depending of the scene complexity. Results can surely be improved by using a special suited multiprocessors cards.

  • PDF

Evaluation of Muscle Activity and Foot Pressure during Gait, and Isokinetic Strength and Balance in Persons with Functional Ankle Instability (기능적 발목관절 불안정성의 등속성 근력과 균형 및 보행 중에 근활성도와 발바닥압의 평가)

  • Lee, Sun-Ah;Kim, Ah-Ram;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.27-37
    • /
    • 2018
  • PURPOSE: The purpose of this study was to investigate and evaluate muscle activity and foot pressure during gait, and isokinetic strength and balance in persons with functional ankle instability (FAI). METHODS: Nine healthy subjects (CON, n=9) without FAI and 11 patients (FAI, n=11) with FAI participated in the study after having been screened with an ankle instability instrument and a balance error scoring system. In addition, FAI was classified as non-involved (FAI-N) or involved (FAI-I), and CON was classified as dominant or non-dominant. All subjects were evaluated for isokinetic strength (plantar flexion, dorsiflexion, inversion and eversion of $30^{\circ}/sec$ and $60^{\circ}/sec$), balance (static and dynamic), muscle activity (tibialis anterior, peroneus longus and gastrocnemius) and foot pressure (static and dynamic) during gait. RESULTS: Results showed that plantar flexion (p<.05), dorsiflexion (p<.05), inversion (p<.01) and eversion (p<.00) of $60^{\circ}/sec$ were significantly decreased in FAI-I compared to those in FAI-N and CON. C 90 of static balance with eyes open (p<.01) and closed (p<.00) were significantly increased in FAI compared to those in CON. Forward position of dynamic balance (p<.01) was significantly decreased in FAI compared to that in CON. Gastrocnemius and peroneus longus of dynamic muscle activity (p<.01), left and right weight distribution of static foot pressure (p<.00) and pressure distribution of dynamic foot pressure (p<.00) were significantly decreased in FAI-I compared to those in FAI-N. CONCLUSION: We demonstrated that ankle strength, balance, muscle activity and foot pressure were significantly correlated with FAI.

Effect of an 8-week Closed Kinetic Chain Styled Pilates Exercise on Lower Limb Alignment (8주간 닫힌 사슬형 필라테스 운동이 하지 정렬에 미치는 영향)

  • Ga Ram Jeon;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.128-136
    • /
    • 2023
  • Objective: The aim of this study was to investigate the effect of an 8-week closed kinetic chain typed Reformer and Chair Pilates exercise on static and dynamic lower limb alignment for healthy female adults. Method: Ten healthy young female adults without musculoskeletal injury history in last 6 months (Age: 29.3 ± 3.5 yrs., Height: 165 ± 3.4 cm, Body mass: 58.2 ± 5.4 kg) participated in this study. All participants asked to join the 8-week closed kinetic chain typed Reformer and Chair Pilates exercise, and the program was conducted for 60 minutes twice a week. Participants were asked to be measure a static Q-angle and performed free squat one week before and after the program. A 3-D motion analysis with 8 infrared cameras and 5 channels of EMG was executed in this study. The effectiveness of the training was evaluated by paired t-test, and the significance level was set at .05. Results: A significantly decreased in internal rotation angles was found at hip joint during free squat after the training. Also, significantly decreased in lateral rotation angles were found at knee and ankle joint during free squat after training. Finally, significantly decreased in muscle activations were found at adductor longus and peroneus longus during free squat after training. Conclusion: From results of our study, it is concluded that an 8-week closed kinetic chain typed Pilates exercise positively effect on lower limb alignment during dynamic movement.

Comparison of Ankle Joint Exercise and Thigh Exercise on the Isometric Strength of the Lower Limb and Balance Ability (다리 등척성 근력 및 균형 능력에 대한 발목관절 운동과 넓적다리 운동의 비교)

  • Lee, Woo-Jung;Lee, Sun-Ah;Kim, Ah-Ram;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.4
    • /
    • pp.153-162
    • /
    • 2019
  • PURPOSE: This study compared ankle joint exercise and thigh exercise on the isometric strength of the lower limb and balance ability. METHODS: Twenty-seven subjects were divided into ankle joint exercise (AEG, n=9), tight exercise (TEG, n=9), and control group (CON, n=9). AEG and TEG performed ankle joint and tight exercises three times a week for four weeks. The following were measured before and four weeks after each exercise: isometric strength at knee flexion and extension of the lower limb; isometric strength at ankle plantar flexion and dorsiflexion of the lower limb; static balance of trace length and C90 area; and the dynamic forward, backward, leftward, and rightward balance for each region. RESULTS: The results showed that the isometric strength of plantar flexion (p<.05) was increased significantly in AEG compared to those in TEG and CON. The dynamic leftward (p<.05) and rightward balance (p<.05) were increased significantly in both AEG and TEG compared to that in CON. On the other hand, the static balance of the trace length and C90 area, isometric strength of ankle dorsiflexion, knee flexion and extension of the lower limb, and dynamic forward and backward balance did not show significant differences between the groups. CONCLUSION: Ankle joint exercise improves the isometric strength of plantar flexion compared to tight exercise.