• 제목/요약/키워드: Standardized Software

검색결과 278건 처리시간 0.027초

Association Between Cognitive Impairment and Oral Health Related Quality of Life: Using Propensity Score Approaches (인지기능과 구강건강관련 삶의 질의 연관성에 대한 연구: 성향점수 분석과 회귀모델을 중심으로)

  • Cha, Suna;Bae, Suyeong;Nam, Sanghun;Hong, Ickpyo
    • Therapeutic Science for Rehabilitation
    • /
    • 제12권3호
    • /
    • pp.61-77
    • /
    • 2023
  • Objective : This study analyzed the correlation between cognitive function and oral health-related quality of life (OHQoL). Methods : Demographic and clinical characteristics were extracted and utilized for subjects aged 45 years or older who participated in the 8th Korean Longitudinal Study on Aging in 2020. The dependent variable was the Geriatric Oral Health Assessment Index, and the independent variable was the level of cognitive function classified by the Mini-Mental State Examination scores. The analysis method used inverse probability of treatment weighting (IPTW). Then, the association between cognitive function and OHQoL was analyzed by multiple regression analysis. Results : Among the participants, 4,367 (71.40%) had normal cognition, 1,155 (18.89%) had moderate cognitive impairment, and 594 (9.71%) had severe cognitive impairment. As a result of analysis by applying IPTW, there was a negative correlation between the cognitive function group and OHQoL (normal vs. moderate: β = -2.534, p < .0001; normal vs. severe: β = -2.452, p < .0001). Conclusion : After propensity score matching, mild cognitive impairment showed a more negative association than severe cognitive impairment. Therefore, patients with cognitive impairment require oral health management education to improve OHQoL regardless of the level of cognitive impairment.

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Research and improvement of image analysis and bar code and QR recognition technology for the development of visually impaired applications (시각장애인 애플리케이션 개발을 위한 이미지 분석과 바코드, QR 인식 기술의 연구 및 개선)

  • MinSeok Cho;MinKi Yoon;MinSu Seo;YoungHoon Hwang;Hyun Woo;WonWhoi Huh
    • The Journal of the Convergence on Culture Technology
    • /
    • 제9권6호
    • /
    • pp.861-866
    • /
    • 2023
  • Individuals with visual impairments face difficulties in accessing accurate information about medical services and medications, making it challenging for them to ensure proper medication intake. While there are healthcare laws addressing this issue, there is a lack of standardized solutions, and not all over-the-counter medications are covered. Therefore, we have undertaken the design of a mobile application that utilizes image recognition technology, barcode scanning, and QR code recognition to provide guidance on how to take over-the-counter medications, filling the existing gaps in the knowledge of visually impaired individuals. Currently available applications for individuals with visual impairments allow them to access information about medications. However, they still require the user to remember which specific medication they are taking, posing a significant challenge. In this research, we are optimizing the camera capture environment, user interface (UI), and user experience (UX) screens for image recognition, ensuring greater accessibility and convenience for visually impaired individuals. By implementing the findings from our research into the application, we aim to assist visually impaired individuals in acquiring the correct methods for taking over-the-counter medications.

Permanent Preservation and Use of Historical Archives : Preservation Issues Digitization of Historical Collection (역사기록물(Archives)의 항구적인 보존화 이용 : 보존전략과 디지털정보화)

  • Lee, Sang-min
    • The Korean Journal of Archival Studies
    • /
    • 제1호
    • /
    • pp.23-76
    • /
    • 2000
  • In this paper, I examined what have been researched and determined about preservation strategy and selection of preservation media in the western archival community. Archivists have primarily been concerned with 'preservation' and 'use' of archival materials worth of being preserved permanently. In the new information era, preservation and use of archival materials were faced with new challenge. Life expectancy of paper records was shortened due to acidification and brittleness of the modem papers. Also emergence of information technology affects the traditional way of preservation and use of archival materials. User expectations are becoming so high technology-oriented and so complicated as to make archivists act like information managers using computer technology rather than traditional archival handicraft. Preservation strategy plays an important role in archival management as well as information management. For a cost-effective management of archives and archival institutions, preservation strategy is a must. The preservation strategy encompasses all aspects of archival preservation process and practices, from selection of archives, appraisal, inventorying, arrangement, description, conservation, microfilming or digitization, archival buildings, and access service. Those archival functions should be considered in their relations to each other to ensure proper preservation of archival materials. In the integrated preservation strategy, 'preservation' and 'use' should be combined and fulfilled without sacrificing the other. Preservation strategy planning is essential to determine the policies of archives to preserve their holdings safe and provide people with a maximum access in most effective ways. Preservation microfilming is to ensure permanent preservation of information held in important archival materials. To do this, a detailed standardization has been developed to guarantee the permanence of microfilm as well as its product quality. Silver gelatin film can last up to 500 years in the optimum storage environment and the most viable option for permanent preservation media. ISO and ANIS developed such standards for the quality of microfilms and microfilming technology. Preservation microfilming guidelines was also developed to ensure effective archival management and picture quality of microfilms. It is essential to assess the need of preservation microfilming. Limit in resources always put a restraint on preservation management. Appraisal (and selection) of what to be preserved was the most important part of preservation microfilming. In addition, microfilms with standard quality can be scanned to produce quality digital images for instant use through internet. As information technology develops, archivists began to utilize information technology to make preservation easier and more economical, and to promote use of archival materials through computer communication network. Digitization was introduced to provide easy and universal access to unique archives, and its large capacity of preserving archival data seems very promising. However, digitization, i.e., transferring images of records to electronic codes, still, needs to be standardized. Digitized data are electronic records, and st present electronic records are very unstable and not to be preserved permanently. Digital media including optical disks materials have not been proved as reliable media for permanent preservation. Due to their chemical coating and physical character using light, they are not stable and can be preserved at best 100 years in the optimum storage environment. Most CD-R can last only 20 years. Furthermore, obsolescence of hardware and software makes hard to reproduce digital images made from earlier versions. Even if when reformatting is possible, the cost of refreshing or upgrading of digital images is very expensive and the very process has to be done at least every five to ten years. No standard for this obsolescence of hardware and software has come into being yet. In short, digital permanence is not a fact, but remains to be uncertain possibility. Archivists must consider in their preservation planning both risk of introducing new technology and promising possibility of new technology at the same time. In planning digitization of historical materials, archivists should incorporate planning for maintaining digitized images and reformatting them in the coming generations of new applications. Without the comprehensive planning, future use of the expensive digital images will become unavailable. And that is a loss of information, and a final failure of both 'preservation' and 'use' of archival materials. As peter Adelstein said, it is wise to be conservative when considerations of conservations are involved.

Ultrasound-Guided Local Steroid Injection Therapy for Acute Calcific Tendinitis of Shoulder (초음파를 이용한 급성 극상근 석회화 건염의 스테로이드 국소 주사 요법)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Kang, Min-Ku
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • 제2권2호
    • /
    • pp.85-89
    • /
    • 2009
  • Purpose: To analyze the clinical outcome after ultrasound guided multiple dry needlings and local steroid injection for acute calcific tendinitis of shoulder. Materials and Methods: Twenty patients with acute episode of pain by calcific tendinitis of shoulder with average age 58.2 (50~70 years) and follow-up of 18 months in average (range, 12~24) were included in study. There were 18 patients with right and 2 with left sided involvement. All patients had calcific deposits in the supraspinatus tendon. All patients underwent standardized nonoperative treatment protocol, consisting of 5~12 MHz high resolution ultrasound guided multiple dry needlings with 18 guage needle, followed by 2% lidocaine 1cc and 40 mg/ml depomedrol 1cc injection at site of calcific tendinitis. The outcome was assessed by UCLA shoulder score, range of motion and VAS score. A statistical analysis with ANOVA and Tukey's post-hoc test with the significance level at 5% was performed using SAS 9.1 software (SAS Institute, Cary, NC). Results: All patients got continuous relief of pain right after the procedures until final follow-up. Before the procedures, the UCLA scores were fair in 15 patients and poor in 5. After the procedures, the UCLA scores were excellent in 16 patients and good in 4. All cases revealed no limitation of shoulder function. The average VAS score decreased from 8.9 before the procedures to 0.5 at final follow-up (p<0.0001). No complication was encountered. Conclusion: An ultrasound guided local steroid injections following multiple dry needlings would be one of the useful treatment modality for the acute calcific tendinitis of shoulder.

  • PDF

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • 제16권5호
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제20권2호
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF