• Title/Summary/Keyword: Standardized Mode

Search Result 72, Processing Time 0.021 seconds

Fine-tuning SVM for Enhancing Speech/Music Classification (SVM의 미세조정을 통한 음성/음악 분류 성능향상)

  • Lim, Chung-Soo;Song, Ji-Hyun;Chang, Joon-Hyuk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.141-148
    • /
    • 2011
  • Support vector machines have been extensively studied and utilized in pattern recognition area for years. One of interesting applications of this technique is music/speech classification for a standardized codec such as 3GPP2 selectable mode vocoder. In this paper, we propose a novel approach that improves the speech/music classification of support vector machines. While conventional support vector machine optimization techniques apply during training phase, the proposed technique can be adopted in classification phase. In this regard, the proposed approach can be developed and employed in parallel with conventional optimizations, resulting in synergistic boost in classification performance. We first analyze the impact of kernel width parameter on the classifications made by support vector machines. From this analysis, we observe that we can fine-tune outputs of support vector machines with the kernel width parameter. To make the most of this capability, we identify strong correlation among neighboring input frames, and use this correlation information as a guide to adjusting kernel width parameter. According to the experimental results, the proposed algorithm is found to have potential for improving the performance of support vector machines.

A Fast Inter-layer Mode Decision Method inScalable Video Coding (공간적 스케일러블 비디오 부호화에서 계층간 모드 고속 결정 방법)

  • Lee, Bum-Shik;Hahm, Sang-Jin;Park, Chang-Seob;Park, Keun-Soo;Kim, Mun-Churl
    • Journal of Broadcast Engineering
    • /
    • v.12 no.4
    • /
    • pp.360-372
    • /
    • 2007
  • We propose a fast inter-layer mode decision method by utilizing coding information of base layer upward its enhancement layer inscalable video coding (SVC), also called MPEG-4 part 10 Advanced Video Coding Amendment 3 or H.264 Scalable Extension (SE) which is being standardized. In this paper, when the motion vectors from the base layer have zero motion (0, 0) in inter-layer motion prediction or the Integer Transform coefficients of the residual between current MB and the motion compensated MB by the predicted motion vectors from the base layer are all zero, the block mode of the corresponding block to be encoded at the enhancement layer is determined to be the $16{\times}16$ mode. In addition, if the predicted mode of the MB to be encoded at the enhancement layer is not equal to the $16{\times}16$ mode, then the rate-distortion optimization is only performed on the reduced candidated modes which are same or smaller partitioned modes. Our proposed method exhibits the complexity reduction in encoding time up to 72%. Nevertheless, it shows negligible PSNR degradation and bit rate increase up to 0.25dB and 1.73%, respectively.

A Study on the Size Designation and Basic Product Size of Women's Knitwear (Knitwear의 사이즈 호칭(呼稱)과 기본제품(基本製品)치수에 관(關)한 실태(實態) 조사(調査))

  • Kim, Eun-Hee;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.4 no.3
    • /
    • pp.131-139
    • /
    • 2000
  • The purpose of this study is to provide for the basic data useful to the knitwear size standards for the effective production. For this purpose, knit promotions that product knitwear for 20 age $\sim$ 30 middle age women were sampled to survey their condition of the size designation and basic product size of knitwear, and their directors were surveyed through direct interviews. Data is processed by a computer(SPSS) and analyzed by using frequency, percentage, mean and mode. The results of this study are as follows. 1. Size designation and bodysize of knitwear are not standardized. 2. Knit promotions that don't mark bodysize on the size designation label are not a few. 3. Cardigan's sizes except for a few part are equal to round/pola T-shirt's sizes or are large more than those.

  • PDF

Multiple Battery Module for the Low-Earth-Orbit Spacecraft Power system

  • Cho Yoon-Jay;Cho B. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.84-88
    • /
    • 2001
  • In an effort to develop more reliable and cost-effective satellite power system, a multiple-battery subsystem operating in parallel become a viable solution. The idea can further be extended to the parallel-able standardized battery module concept that offers many attractive features in configuring a spacecraft power system. In this paper, Multiple Battery Modules employing the charge control scheme are proposed. In addition to the conventional voltage mode controller, the charge control scheme internally regulates and controls the battery current, resulting in the identical current distribution and balanced battery charge.

  • PDF

The Influence of CNTs and Lamination Structure on the Intralaminar Fracture of CFRP/GFRP Composites (CFRP/GFRP 복합재료의 층내 파괴에 대한 CNT 및 적층구조의 영향)

  • Kim, Seong Hun;Yun, Yu Seong;Kang, Ji Woong;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.9-15
    • /
    • 2017
  • Recently many researches were conducted on the interlaminar fracture that is a delamination between laminates by using ASTM standardized methods. However the experiment of the intralaminar a fracture is difficulty. In this study, four types of CFRP/GFRP composites with different layer structures were compared to evaluate an intralaminar fracture toughness under the mode I. Also the CNTs were added to the layer for the examination of the fracture toughness improvement. And the characteristics of the crack propagation behaviour was observed using a microscope. The obtained results can be useful for the evaluation of the intralaminar fracture toughness of the CNT reinforced CFRP/GFRP composites.

Standardization of a Remote Motoring and Controlling System for Nursery Electrical Facilities (양식장 전력설비의'원격 감시 및 제어 시스템 표준화)

  • 권장우;김정인;송재용;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.398-401
    • /
    • 2000
  • This paper describes the standardization of remote monitoring and controlling system for nursery electrical facilities. The proposed system have three operating modes of motoring, controlling, and fault-notifying. In fault-notifying mode, the local unit is designed to send messages on failure of the electrical facilities to the central computer, mobile phone, and pager. Also, the local unit is consisted of 24-input and 8-output port needed for monitoring and controlling the facilities. With the use of this standardized system, we could expect the effective management in every phase of nursery facilities.

  • PDF

Impact of External Temperature Environment on Large FCBGA Sn-Ag-Cu Solder Interconnect Board Level Mechanical Shock Performance

  • Lee, Tae-Kyu
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • The mechanical stability of solder joints in electronic devices with Sn-Ag-Cu is a continuous issue since the material was applied to the industry. Various shock test methods were developed and standardized tests are used in the industry worldwide. Although it is applied for several years, the detailed mechanism of the shock induced failure mechanism is still under investigation. In this study, the effect of external temperature was observed on large Flip-chip BGA components. The weight and size of the large package produced a high strain region near the corner of the component and thus show full fracture at around 200G level shock input. The shock performance at elevated temperature, at $100^{\circ}C$ showed degradation based on board pad designs. The failure mode and potential failure mechanisms are discussed.

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

Development of Electrical Power Subsystem of Cube Satellite STEP Cube Lab for Verification of Space-Relevant Technologies

  • Park, Tae-Yong;Chae, Bong-Geon;Oh, Hyun-Ung
    • International Journal of Aerospace System Engineering
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2016
  • STEP Cube Lab (Cube Laboratory for Space Technology Experimental Project) is a 1U standardized pico-class satellite. Its main mission objective is an on-orbit verification of five fundamental core space technologies. For assuring a successful missions of the STEP Cube Lab with five payloads, electrical power subsystem (EPS) shall sufficiently provide an electrical power to payloads and bus systems of the satellite during an entire mission life. In this study, a design process of EPS system was introduced including power budget analysis considering a mission orbit and various mission modes of the satellite. In conclusion, adequate EPS hardware in compliance with design requirements were selected. The effectiveness and mission capability of EPS architecture design were confirmed through an energy balance analysis (EBA).

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.