• Title/Summary/Keyword: Standard type

Search Result 4,472, Processing Time 0.03 seconds

Men's and women's body types in the global garment sizing systems

  • Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.6
    • /
    • pp.923-936
    • /
    • 2012
  • Apparel companies define their target customers to integrate consumers' needs into their product development processes. The sizing standards play a significant role in ready-to-wear garment business. Consumers' body build and sizes are different according to gender, age, and body type. The consumers' morphological feature of the one geographical area has changed with immigration, aging, and lifestyle change. In this study the way of defining body types in the standard garment sizing systems published in USA., UK, Germany, Japan, and Korea were compared. The results of this study show that most of the systems classified the body types by the index value. The chest-waist drop value was used for men's body type classification. Women's body types were defined by hip proportion. The hip-bust drop value was used for it. German and European garment sizing systems provide a wide range of men's body types. US men's garment sizes are developed for very conservative body type. US women's garment sizing system has had clearly defined women's body types. The Misses body types projected in the US garment sizing system had changed as women's waist girth got bigger compared to the past. In 2011 the US Misses sizes were divided into Curvy Misses size and Straight Misses size by the hip-waist drop value. The Curvy Misses sizes have smaller waist girth and larger hip girth than the Straight Misses sizes.

A clean technology development using the molybdenum dissolution reaction with hydrogen peroxide/UV/Ozone ($오존/UV/H_2O_2$를 이용한 몰리브덴(Mo) 용해 반응에 따른 청정기술 개발에 관한 연구)

  • 김재우;홍종순;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.143-149
    • /
    • 1999
  • In the tungsten industry as light source material, tungsten filament which used as light source material could form after molybdenumwire which used as the center supporter for coil shape tungsten wire was removed. This process uses hydrogen peroxide, Ozone and UV(Ultraviolet)Lamp, for the quantity of hydrogen peroxide decrease. The results were as follows : 1. An incandescent electric Lamp type : FL(FL-20) type : A standard of commodity (P.W.: $19{\pm}1.0mg$, $C.R:4.5{\pm}0.3{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time : 65Min., P.W.: 18.60mg, $C.R.:4.60{\Omega}$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide; Reaction Time : 64Min., P.W.: 18.61mg, C.R.: $4.61{\Omega}$ 2. A Fluorescent Lamp Type : GLS(GLS-40) Type : A standard of commodity(P.W.: $11.8{\pm}0.2mg$$65{\pm}1.5{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time: 72Min, P.W.:11.88mg, C.R.: $65.62\Omega$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide;Reaction Time:71Min., P.W.:11.88mg, C.R.: $65.63\Omega$

  • PDF

Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter (레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발)

  • 배기윤;이정인
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.

A Study on Structural Analysis of High-Pressure Pipeline Retainer-Type Ball Valve by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 고압 배관용 리테이너형 볼밸브의 구조해석에 관한 연구)

  • Kim, Chul Kyu;Yoon, Joon Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.13-18
    • /
    • 2015
  • This study has been performed to evaluate the safety of the retainer-type ball valve for a high-pressure pipeline to a district heating plant. The retainer-type ball valve is an improved design for conventional ball valves, such as the floating ball valve and the trunnion ball valve. Numerical analysis of the valve design verification has been applied to investigate the safety factor and seat leakage of the DN300 and DN400 sizes. The given condition to solve the structural analysis was based on the international standard for ISO 5208. In this study, the methods for structural analysis are described in detail. The structural analysis results present the deformations, the equivalent stresses, and the safety factors. Through these results, this study successfully demonstrates the safety and seat leakage of the retainer-type ball valve. They also streamline the process of development for valve manufacturing.

The Dyeing Properties of Poly(trimethylene terephthalate) by Disperse Dyes with Different Energy Level (Energy Level이 다른 분산염료를 이용한 Poly(trimethylene terephthalate)섬유의 염색성)

  • 백지연;김정렬;이난형;윤태희;김삼수
    • Textile Coloration and Finishing
    • /
    • v.15 no.5
    • /
    • pp.316-320
    • /
    • 2003
  • In order to investigate the dyeing property of poly trimethylene terephthalate(PTT) fabric, the dyeing of PTT fabric was carried at under condition of different dyeing temperature by using several disperse dyes with different energy level. Particularly, this study discussed the PTT dyeing thermodynamically. Used disperse dyes were selected based on the their chemical structure and energy level. The obtained results were as followings; The dye adsorption of S type disperse dye such as C. I. Disperse Blue 79 increased with increasing dyeing temperature. In a exhaustion rate of PTT fabric with disperse dyes, C. I. Disperse Blue 56 showed higher values than that of C. I. Disperse Orange 29 and Blue 79. For the interpretation of thermodynamic dyeing behavior, the partition coefficient ( K ) and some several thermodynamic parameters such as standard affinity$(-\mu^\circ)$ and heat of dyeing$(\Delta{H}^\circ)$ calculated from the adsorption isotherm. From above results, as the energy level of disperse dye is small, the partition coefficient and standard affinity increased. But the heat of dyeing of PTT fabric with disperse dye showed high negative value in order of E type(C. I. Disperse Blue 56), SE type(C. I. Disperse Orange 29) and S type(C. I. Disperse 79).

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN ORTHODONTIC BRACKET & ARCHWIRE (교정용 BRACKET과 ARCHWIRE 사이의 마찰저항에 대한 비교연구)

  • Sung, Hyun Mee;Park, Young Chel
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.543-560
    • /
    • 1991
  • Practitioners are aware of the presence of friction between bracket system and archwire during sliding movement of teeth. Clinically a mesiodistally applied force must exceed the frictional force to produce a tooth movement. The objective of this study were to determine, on a dry condition, changes in magnitude of friction with respect to load, 3rd order inclination (Torque), archwire materials and ligature type. Three wire alloys (Stainless Steel, TMA, NiTi) in two wire sizes (.016, .016x, .022 inch) were examined respect to two bracket system (Straight, Standard), and two ligature type (Metal, Plastic ligature) at three levels of load (100g, 150g, 200g). The results were as follows; 1. Frictional resistance was found to increase with increasing load for S.S., TMA, NiTi. 2. The straight bracket system was exhibited more frictional force than standard bracket system for .016x, .022 S.S. tightly ligated metal ligature. But, torque difference did not increase friction for loose metal ligature & plastic ligature. 3. Regardless of the ligature type, torque and load, stainless steel wire sliding against stainless steel exhibited the lowest friction, and TMA sliding against stainless steel exhibited the highest friction. 4. The loose stainless steel ligature generated lower frictional resistance than plastic ligature in all experimental groups. 5. The following factors affected friction in decreasing order; wire material ligature type, and load.

  • PDF

Obstacle Classification Method using Multi Feature Comparison Based on Single 2D LiDAR (단일 2차원 라이다 기반의 다중 특징 비교를 이용한 장애물 분류 기법)

  • Lee, Moohyun;Hur, Soojung;Park, Yongwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.253-265
    • /
    • 2016
  • We propose an obstacle classification method using multi-decision factors and decision sections based on Single 2D LiDAR. The existing obstacle classification method based on single 2D LiDAR has two specific advantages: accuracy and decreased calculation time. However, it was difficult to classify obstacle type, and therefore accurate path planning was not possible. To overcome this problem, a method of classifying obstacle type based on width data was proposed. However, width data was not sufficient to enable accurate obstacle classification. The proposed algorithm of this paper involves the comparison between decision factor and decision section to classify obstacle type. Decision factor and decision section was determined using width, standard deviation of distance, average normalized intensity, and standard deviation of normalized intensity data. Experiments using a real autonomous vehicle in a real environment showed that calculation time decreased in comparison with 2D LiDAR-based method, thus demonstrating the possibility of obstacle type classification using single 2D LiDAR.

VLSI Design of Data Manipulation Unit capable of bit partitioned shifts and various data type conversions (비트 분할 데이터 시프트 및 다양한 형식 변환이 가능한 데이터 처리기의 VLSI 설계)

  • 유재희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6C
    • /
    • pp.594-600
    • /
    • 2002
  • A data manipulation unit capable of bit partitioned shift and various multimedia data type conversions in addition to conventional shift, is presented. Utilizing the similarity between the data type conversion and the shift, the addition of small amount of interconnections to conventional barrel shifter enables data type conversion as well as shift operations with minimal hardware overhead. The presented data manipulation unit is composed of the shifter block for conventional shift and a pack and a unpack block. It has been designed with verilog HDL and the VLSI implementation results using compass 0.6 um standard cell are discussed.

Leachability of lead, cadmium, and antimony in cement solidified waste in a silo-type radioactive waste disposal facility environment

  • Yulim Lee;Hyeongjin Byeon;Jaeyeong Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2889-2896
    • /
    • 2023
  • The waste acceptance criteria for heavy metals in mixed waste should be developed by reflecting the leaching behaviors that could highly depend on the repository design and environment surrounding the waste. The current standards widely used to evaluate the leaching characteristics of heavy metals would not be appropriate for the silo-type repository since they are developed for landfills, which are more common than a silo-type repository. This research aimed to explore the leaching behaviors of cementitious waste with Pb, Cd, and Sb metallic and oxide powders in an environment simulating a silo-type radioactive waste repository. The Toxicity Characteristic Leaching Procedure (TCLP) and the ANS 16.1 standard were employed with standard and two modified solutions: concrete-saturated deionized and underground water. The compositions and elemental distribution of leachates and specimens were analyzed using an inductively coupled plasma optical emission spectrometer (ICP-OES) and energy-dispersive X-ray spectroscopy combined with scanning electron microscopy (SEM-EDS). Lead and antimony demonstrated high leaching levels in the modified leaching solutions, while cadmium exhibited minimal leaching behavior and remained mainly within the cement matrix. The results emphasize the significance of understanding heavy metals' leaching behavior in the repository's geochemical environment, which could accelerate or mitigate the reaction.