• Title/Summary/Keyword: Standard source

Search Result 1,559, Processing Time 0.029 seconds

Occupational Demands and Educational Needs in Korean Librarianship (한국적 도서관학교육과정 연구)

  • Choi Sung Jin;Yoon Byong Tae;Koo Bon Young
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.12
    • /
    • pp.269-327
    • /
    • 1985
  • This study was undertaken to meet more fully the demands for improved training of library personnel, occasioned by the rapidly changing roles and functions of libraries as they try to adapt to the vast social, economic and technological changes currently in progress in the Korean society. The specific purpose of this research is to develop a standard curriculum at the batchelor's level that will properly equip the professional personnel in Korean libraries for the changes confronting them. This study started with the premise that to establish a sound base for curriculum development, it was necessary first to determine what concepts, knowledge, and techniques are required for professional library personnel to perform it at an optimal level of efficiency. Explicitly, it was felt that for the development of useful curricula and courses at the batchelor's level, a prime source of knowledge should be functional behaviours that are necessary in the job situation. To determine specifically what these terminal performance behaviours should be so that learning experience provided could be rooted in reality, the decision was reached to use a systems approach to curriculum development, which is an attempt to break the mold of traditional concepts and to approach interaction from an open, innovative, and product-oriented perspective. This study was designed to: (1) identify what knowledge and techniques are required for professional library personnel to perform the job activities in which they are actually engaged, (2) to evaluate the educational needs of the knowledge and techniques that the professional librarian respondents indicate, and (3) to categorise the knowledge and techniques into teaching subjects to present the teaching subjects by their educational importance. The main data-gathering instrument for the study, a questionnaire containing 254 items, was sent to a randomly selected sample of library school graduates working in libraries and related institutions in Korea. Eighty-three librarians completed and returned the questionnaire. After analysing the returned questionnaire, the following conclusions have been reached: (A) To develop a rational curriculum rooted in the real situation of the Korean libraries, compulsory subjects should be properly chosen from those which were ranked highest in importance by the respondents. Characters and educational policies of, and other teaching subjects offered by, the individual educational institution to which a given library school belongs should also be taken into account in determining compulsory subjects. (B) It is traditionally assumed that education in librarianship should be more concerned with theoretical foundations on which any solution can be developed than with professional needs with particulars and techniques as they are used in existing library environments. However, the respondents gave the former a surprisingly lower rating. The traditional assumption must be reviewed. (C) It is universally accepted in developing library school curricula that compulsory subjects are concerned with the area of knowledge students generally need to learn and optional subjects are concerned with the area to be needed to only those who need it. Now that there is no such clear demarcation line provided in librarianship, it may be a realistic approach to designate subjects in the area rated high by the respondents as compulsory and to designate those in the area rated low as optional. (D) Optional subjects that were ranked considerably higher in importance by the respondents should be given more credits than others, and those ranked lower might be given less credits or offered infrequently or combined. (E) A standard list of compulsory and optional subjects with weekly teaching hours for a Korean library school is presented in the fourth chapter of this report.

  • PDF

A Study on the Standardization of QSCCII (Questionnaire for the Sasang Constitution Classification II) (사상체질분류검사지(四象體質分類檢査紙)(QSCC)II의 표준화(標準化) 연구(硏究) -각(各) 체질집단(體質集團)의 군집별(群集別) Profile 분석(分析)을 중심(中心)으로-)

  • Kim, Sun Ho;Go, Byeong-Hui;Song, Il-Byeong
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.187-246
    • /
    • 1996
  • The purpose of this study is to evaluate and standardize the four scales of Questionnaire for the Sasang Constitution ClassificationII (QSCCII). QSCCII is newly prepared by statistical item analysis and is designed to examine its diagnostic discriminability. QSCCII is administered to 1366 random informants. From the survey, we could get the data for the standardization. The criteria of standardization are based on the data from 265 informants who are examined by professionals. Collected data are analyzed by internal consistency, variation analysis(ANOVA), Duncan test and discrimination analysis of SPSS PC+ V4.0 program. The results are as follows 1) The reliability of four scales for QSCCII is relatively valid. The internal consistency of Tae-yang(太陽) scale is Cronbach's ${\alpha}=0.5708$. That of So-yang(少陽) scale is ${\alpha}=0.5708$. That of Tae-eum(太陰) scale is ${\alpha}=0.5922$. That of So-eum(少陰) scale is ${\alpha}=0.6319$. 2) There is a significant difference between each group through variation analysis of four scales. 3) The process of standardization is based on the average value and standard deviation with respect to age and sex difference of each criteria. 4) This study suggests a source of standardization of Sasang Constitution Classification by providing norms in which the differences of age, sex, and number of items are taken into deep consideration. QSCCII, therefore, can be applied to every age(the 10's to the 60's) and sex groups. 5) The recalculation of the raw-score to standard value (T-score) shows that the diagnostic discriminability (Hit-ratio : 70.08%) of QSCCII brings about 37% improvement than proportional chance criteria(33.33%). Especially, Hit-ratios of Tae-eum In(74.5%) and So-eum In(70.8%) are higher than that of So-yang In(60.0%). 6) QSCC has discriminability only to male informants. Compared with QSCC, however, QSCCII has relatively efficient discriminability both to male and female informants. 7) These results would be a demonstration of the fact that the QSCCII could be used as a tool for sasang constitution classification.

  • PDF

Decrease of Aflatoxin M1 Level in Raw Cow’s Milk using the Hazard Analysis and Critical Control Points (HACCP) System (HACCP 제도에 의한 우유의 아플라톡신 M1의 저감화)

  • Kim, Ki-Hwan;Nam, Myoung Soo
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.190-197
    • /
    • 2016
  • Aflatoxin M1 can be produced in cow’s milk when cows eat contaminated produce. Milk is a major source of food for infants and for children who have a weak level of immunity, and the detection of Aflatoxin M1 for risk assessment is necessary in order to reduce the amount of it in milk. In this study, the Aflatoxin M1 level was monitored for one year in raw milk samples obtained from Chungnam Province, Korea. The milk samples were divided into three categories: 1. milk samples from a standard general farm, 2. milk samples from a HACCP controlled farm, and 3. milk samples from the supply of Aflatoxin M1 reduced fodder. The average concentrations of Aflatoxin M1 in milk were 0.023±0.005 ug/l for the standard general farm, 0.017±0.004 ug/l for the HACCP controlled farm, and 0.013±0.003 ug/l for the supply of Aflatoxin M1 reduction fodder. Milk collected from the supply of Aflatoxin M1 reduction fodder had the lowest level of Aflatoxin M1. However, when efficiency and economic aspects are considered the most effective way of reducting Aflatoxin M1, could be taking milk from the HACCP controlled farm and implementing good feed management. Institutional support from the government, careful management of dairy farming, and a strict farm sanitation program are required in order to lower the level of Aflatoxin M1 in milk.

Analysis of Uncertainty in Ocean Color Products by Water Vapor Vertical Profile (수증기 연직 분포에 의한 GOCI-II 해색 산출물 오차 분석)

  • Kyeong-Sang Lee;Sujung Bae;Eunkyung Lee;Jae-Hyun Ahn
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1591-1604
    • /
    • 2023
  • In ocean color remote sensing, atmospheric correction is a vital process for ensuring the accuracy and reliability of ocean color products. Furthermore, in recent years, the remote sensing community has intensified its requirements for understanding errors in satellite data. Accordingly, research is currently addressing errors in remote sensing reflectance (Rrs) resulting from inaccuracies in meteorological variables (total ozone, pressure, wind field, and total precipitable water) used as auxiliary data for atmospheric correction. However, there has been no investigation into the error in Rrs caused by the variability of the water vapor profile, despite it being a recognized error source. In this study, we used the Second Simulation of a Satellite Signal Vector version 2.1 simulation to compute errors in water vapor transmittance arising from variations in the water vapor profile within the GOCI-II observation area. Subsequently, we conducted an analysis of the associated errors in ocean color products. The observed water vapor profile not only exhibited a complex shape but also showed significant variations near the surface, leading to differences of up to 0.007 compared to the US standard 62 water vapor profile used in the GOCI-II atmospheric correction. The resulting variation in water vapor transmittance led to a difference in aerosol reflectance estimation, consequently introducing errors in Rrs across all GOCI-II bands. However, the error of Rrs in the 412-555 nm due to the difference in the water vapor profile band was found to be below 2%, which is lower than the required accuracy. Also, similar errors were shown in other ocean color products such as chlorophyll-a concentration, colored dissolved organic matter, and total suspended matter concentration. The results of this study indicate that the variability in water vapor profiles has minimal impact on the accuracy of atmospheric correction and ocean color products. Therefore, improving the accuracy of the input data related to the water vapor column concentration is even more critical for enhancing the accuracy of ocean color products in terms of water vapor absorption correction.

Effects of Light Intensity, Nutrient Solution Compositions before Harvest and the Time of Nutrient Solution Removal on Nitrate Contents in Hydroponically-Grown Leaf Lettuces in Closed Plant Production System (폐쇄형 식물생산시스템에서 광도, 수확 전 양액조성 및 양액결제시기가 잎상추의 체내 질산염 함량에 미치는 영향)

  • Yeo, Kyung-Hwan;Choi, Gyeong-Lee;Lee, Jung-Sup;Lee, Jae-Han;Park, Kyoung-Sub;Kim, Jin-Hyun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.393-401
    • /
    • 2017
  • The nitrate ($NO_3{^-}$) accumulation of hydroponically grown leafy vegetables may increase in the condition of a closed-type plant production system with low light intensity due to low activity of enzymes involved in nitrogen assimilation and the use of $NO_3-N$ as major nitrogen source. The objective of this study is to investigate the effects of light intensities, nutrient solution compositions and the time of nutrient solution removal before harvest on nitrate contents of hydroponically-grown lettuces in a closed plant production system. The reduction of nitrate contents in leafy lettuces 'Cheongchima' was higher in the treatments of 'TW' (nutrient solution removal) and '$(NH_4)_2CO_3$' (use of ammonium carbonate as nitrogen source) than those in other treatments, which significantly lowered fresh weight and leaf area of the plants. In the light intensity of $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, the nitrate content was effectively reduced without causing any growth retardation, by substitution of the nutrient solution composition that $NO_3-N$ was removed ('$NO_3-N$ removal' treatment) or the half strength of standard nutrient solution was applied ('1/2 S' treatment), for 7days before harvest. The effects of light intensity and the time of nutrient solution removal before harvest on growth and nitrate contents in leafy lettuces were investigated. The nitrate contents in leaves under the light condition of $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ before nutrient solution removal were lower than those of 100 or $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The removal of nutrient solution for 7 days before harvest quickly reduced the amount of nitrates in leaves in all the light intensities with a greater degree under the $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ of light condition, while the 7 days-removal with both 200 and $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ of light conditions caused decrease in 16~31% of leaf area and 20~35% of fresh weight, compared to the 3 days-removal treatment. The nitrate contents were greatly reduced from 3,018 to 1,035 in $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and 2,021 to 480 ppm in the light condition of $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, with the nutrient solution removal for 3 days before harvest, without causing any deterioration in growth and product quality. The vitamin C contents in leaves were higher in the treatment of nutrient solution removal for both 3 and 5 days before harvest with the light condition of $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ than those in the light condition of 100 or $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$.

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Quantification of kerosene and Diesel in Mixed Petroleum Fuels for Environmental Sample Characterization (다종유류 오염 환경매체에서의 유류 분리.정량에 관한 연구(I) - 등유, 경유 정량을 중심으로 -)

  • 이군택;이민효
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.23-31
    • /
    • 2000
  • The objective of this study was to develop an effective separation and quantification method for kerosene and diesel in a mixed petroleum fuel (gasoline, kerosene, and diesel) contaminated environmental samples. This investigation was directed to prove the hypothesis that if the source of petroleum fuels were identical, the peak-area ratios of a reference n-alkane to other n-alkane peaks should be a constant even at the different concentrations. In addition, experimental recovery rates were determined to select the reference peaks of kerosene and diesel for peak area ratio measurements. The experimental results showed that the peak area ratios were constant among the samples having different concentrations when the ratios were calculated from areas of $C_{l3}$, $C_{l4}$, and $C_{15}$ peaks for kerosene and $C_{l6}$ and $C_{l7}$ peak for diesel as reference n-alkane peaks. The recovery rates were evaluated by comparing the relative peak area ratios of each reference peaks after making pairs of the kerosene and diesel reference peaks in the samples contained a known amount of gasoline, kerosene, and diesel. The recovery rates(%) Were 107.0$_{{\pm}20.6}$/86.6/ sub $\pm$15.9/ for kerosene- $C_{13}$/diesel- $C_{16}$, 99.6$\pm$$_{17.2}$/86.6$_{{\pm}15.9}$ for kerosene- $C_{14}$/diesel- $C_{16}$, 73.9/$\pm$14.4//86.6$_{{\pm}sub 15.9}$ for kerosene- $C_{15}$ /diesel- $C_{16}$, 109.4$_{{pm}0.8}$/75.9$_{{pm}4.7}$ for kerosene- $C_{13}$/diesel- $C_{17}$, 107.4$_{{pm}7.9}$/75.9$_{{pm}4.7}$ for kerosene- $C_{14}$/diesel- $C_{17}$, and 95.7$_{{pm}4.6}$ /75.9/$\pm$14.6//75.9$_{{pm$}4.7}$ for kerosene- $C_{15}$ /diesel- $C_{17.}$ The above experimental results confirm that all of the reference peak pairs of kerosene and diesel are applicable to the quantitative analysis for the mixed fuel contaminated samples, but the kerosene- $C_{15}$ /diesel- $C_{l7}$ peaks are recommended since the pair has a lower standard deviation than the other pairs.s..s.s.s..s..s.s.s.s.s.

  • PDF

Radiological Dose Analysis to the Public Resulting from the Operation of Daedeok Nuclear Facilities (대덕부지 원자력관련시설 운영에 따른 주민피폭선량 현황분석)

  • Jeong, Hae Sun;Kim, Eun Han;Jeong, Hyo Joon;Han, Moon Hee;Park, Mi Sun;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • This paper describes the results of assessment of radiological dose resulting from operation of the Daedeok nuclear facilities including the HANARO research reactor, which has been performed to assure whether or not to comply with the regulation standards of the radioactive effluents releases. Based on the meteorological data and the radiation source term, the maximum individual doses were evaluated from 2010 to 2012. The atmospheric dispersion and the deposition factors of gaseous effluents were calculated using the XOQDOQ computer code. ENDOS-G and ENDOS-L code systems were also used for maximum individual dose calculation from gaseous and liquid effluents, respectively. The results were compared with the regulation standards for the radioactive effluents presented by the Nuclear Safety and Security Commission (NSSC). The effective doses and the thyroid doses of the maximum individual were calculated at the maximum exposed point in the Daedeok site, and contributions of exposure pathways to the radiological doses resulting from gaseous and liquid radioactive effluents were evaluated at each facility of the Daedeok site. As a result, the maximum exposed age was analysed to be the child group, and the operation of HANARO research reactor had a major effect more than 90% on the individual doses. The main exposure pathways for gaseous radioactive effluent were from ingestion and inhalation. The effective doses and the thyroid doses were considerably influenced by tritium and iodine, respectively. The gaseous radioactive effluents contributed more than 90% on the total doses, whereas the contributions of the liquid radioactive effluents were relatively low. Consequently, the maximum individual dose due to radioactive effluents from the nuclear facilities within the Daedeok site were less than 3% of the regulation standard over 3 years; therefore, it can be concluded that radioactive effluents from the nuclear facilities were well managed, with the radiation-induced health detriment for residents around the site being negligible.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF