• Title/Summary/Keyword: Standard solutions

Search Result 821, Processing Time 0.03 seconds

Design and Implementation of the ebXML Standard Conformance and Interoperability Testing Tools (ebXML 표준 적합성 및 상호운용성 테스트 도구의 설계 및 구현)

  • Lim, Cheol-Su;Park, Byeong-Sub;Choi, Hyun-Sub
    • The KIPS Transactions:PartD
    • /
    • v.11D no.6
    • /
    • pp.1341-1348
    • /
    • 2004
  • As of an international standard in e-business domains, ebXML solutions are required to be tested and authenticated whether they can satisfy the conformance and interoperability requirements. In this paper, we design and implement the ebXML conformance and interoperability testing tools that observe the standard specification in conformity with ebXML Message Service v2.0, ebXML Registry Service v2.0 and ebXML CPP/A Y2.0. With this regard, our research would serve in building the verification and authentication service infrastructure for fitting standard ebXML e-business solutions with ebXML conformance and interoperability testing tools.

Determination of Hydrogen Peroxide Concentration by Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 과산화수소의 농도 측정)

  • 임현량;우영아;장수현;김경미;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.324-330
    • /
    • 2002
  • This experiment was carried out to determine non-destructively the hydrogen peroxide concentration of 3% antiseptic hydrogen peroxide solutions by portable near-infrared (NIR) system. Hydrogen peroxide standards were prepared ranging from 0 to 25.6 w/w% and the NIR spectra of hydrogen peroxide standard solutions were collected by using a quartz cell in 1 mm pathlength. We found the variation of absorbance band due to OH vibration of hydrogen peroxide depending on the concentration around 1400 nm in the second derivatives spectra. Partial least square regression (PLSR) and multilinear regression (MLR) were explored to develop a calibration model over the spectral range 1100-1720 nm. The model using PLSR was better than that using MLR. The calibration showed good results with a standard error of prediction (SEP) of 0.16%. In order to validate the developed calibration model, routine analyses were performed using commercial antiseptic hydrogen peroxide solutions. The hydrogen peroxide values from the NIR calibration model were compared with the values from a redox titration method. The NIR routine analyses results showed good correlation with those of the redox titration method. This study showed that the rapid and non-destructive determination of hydrogen peroxide in the antiseptic solution was successfully performed by portable NIR system without very harmful solvents.

A Study on the Isolative Determination of 4-Morpholine Carboximidoylguanidine Hydrochloride in Ophthalmic Solutions (점안제중(點眼劑中) 4-Morpholine Carboximidoylguanidine Hydrochloride의 분리정량(分離定量))

  • Lah, Woon-Lyong
    • Journal of Pharmaceutical Investigation
    • /
    • v.4 no.1_2
    • /
    • pp.7-12
    • /
    • 1974
  • The isolative determination of 4-Morpholine carboximidoylguanidine Hydrochloride in the ophthalmic solutions was examined by means of colorimetric method using oxidized nitroprusside and sodium hypobromite. According to the results, the following could be summerzied. 1) The wave length of maximun absorption in $650\;m{\mu}$. 2) Beer's Lew is obeyed for $20{\sim}80\;mcg/ml$ in colored solutions. 3) Absorptions of colored solutions must be measured 5 minutes after the addition of oxidized and 5 minutes after the completion of sodium hypobromite. 4) 4-Morpholine carboximidoylguanidine hydrochloride can be determined within standard deviation 2.0%.

  • PDF

Real-time Monitoring of Glucose Using a Differential Refractive Index Detector (시차 굴절률 측정에 의한 실시간 글루코오스 모니터링)

  • 정진갑;이명희;최은경
    • Textile Coloration and Finishing
    • /
    • v.16 no.2
    • /
    • pp.47-51
    • /
    • 2004
  • A differential refractive index detector was used for monitoring glucose contents in textile processing solutions. The sensitivity of the device was high enough to measure 0.05% aqueous glucose solution that could not be measured by normal refractive index measurement. The device was set to monitor glucose concentration continuously in real time by measuring differential refractive index and calibrated by standard glucose solutions in a range of 0.1 to 1.0%. The possibility of industrial application of the device was demonstrated by real-time monitoring of glucose concentration in textile processing solutions such as desizing bath and cellulase treatment bath. Both of solutions contained glucose as a major degraded product. The device would be able to control the weight loss of cellulosic fiber during cellulase treatment since the amount of degraded products in a processing bath is proportional to its weight loss.

Assessment of seismic strengthening solutions for existing low-rise RC buildings in Nepal

  • Chaulagain, Hemchandra;Rodrigues, Hugo;Spacone, Enrico;Varum, Humberto
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.511-539
    • /
    • 2015
  • The main objective of this study is to analytically investigate the effectiveness of different strengthening solutions in upgrading the seismic performance of existing reinforced concrete (RC) buildings in Nepal. For this, four building models with different structural configurations and detailing were considered. Three possible rehabilitation solutions were studied, namely: (a) RC shear wall, (b) steel bracing, and (c) RC jacketing for all of the studied buildings. A numerical analysis was conducted with adaptive pushover and dynamic time history analysis. Seismic performance enhancement of the studied buildings was evaluated in terms of demand capacity ratio of the RC elements, capacity curve, inter-storey drift, energy dissipation capacity and moment curvature demand of the structures. Finally, the seismic safety assessment was performed based on standard drift limits, showing that retrofitting solutions significantly improved the seismic performance of existing buildings in Nepal.

Study to Improve School Catering Service Quality Through Cooking Hardware Upgrade (학교급식의 효율적 개선방안 - 조리설비를 중심으로 -)

  • 장재규;원융희
    • Culinary science and hospitality research
    • /
    • v.3
    • /
    • pp.315-326
    • /
    • 1997
  • The school catering service has gained national attentions and has been expanding unto high schools after offering meals at elementary schools over years. This study is to identify problems and solutions in kitchen hardware areas to provide nutritiously balanced meals to schoolchildren through establishing standard menu planning. The survey analysis shows that 59.2% of dishes except for rice, Kimchi and soup are prepared by oil deep-fired or oil pan broiled. This indicates that school meals are so limited to serve baked or steamed dishes. Main reasons on the limited menu selection is that schools don't have equipment to prepare baking and steaming dishes mainly due to budget issues. All the dietitians who answered the surveys have been requesting to purchase Convotherm Ovens. Improvement solutions to the problems are: Publish the Revised Standard Equipment Layout that may allow to serve baked and steamed dishes. Establish Budget Support Program from the Government.

  • PDF

Treatment of organic dye solutions by electrodialysis

  • Majewska-Nowak, Katarzyna M.
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.203-214
    • /
    • 2013
  • Laboratory tests were performed to determine the efficiency of dye solution desalination by electrodialysis. The study involved anionic dye and mineral salt recovery by obtaining two streams from a salt and dye mixture - dye-rich solution and salt solution. A standard anion-exchange and cation-exchange membranes or monovalent selective anion-exchange membranes were used in the ED stack. It was found that the separation efficiency was strongly dependent on the dye molecular weight. The best results for standard ion-exchange membranes were achieved for the desalination of Direct Black solution. Furthermore, the obtained results implied that the application of monovalent selective anion-exchange membranes improved the recovery of dye and salt solutions - the dye concentration in the diluate remained constant irrespective of the molecular weight of anionic dyes, whereas the salt recovery remained very high (99.5%).

NONTRIVIAL SOLUTIONS FOR BOUNDARY-VALUE PROBLEMS OF NONLINEAR FRACTIONAL DIFFERENTIAL EQUATIONS

  • Guo, Yingxin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.1
    • /
    • pp.81-87
    • /
    • 2010
  • In this paper, we consider the existence of nontrivial solutions for the nonlinear fractional differential equation boundary-value problem(BVP) $-D_0^{\alpha}+u(t)=\lambda[f(t, u(t))+q(t)]$, 0 < t < 1 u(0) = u(1) = 0, where $\lambda$ > 0 is a parameter, 1 < $\alpha$ $\leq$ 2, $D_{0+}^{\alpha}$ is the standard Riemann-Liouville differentiation, f : [0, 1] ${\times}{\mathbb{R}}{\rightarrow}{\mathbb{R}}$ is continuous, and q(t) : (0, 1) $\rightarrow$ [0, $+\infty$] is Lebesgue integrable. We obtain serval sufficient conditions of the existence and uniqueness of nontrivial solution of BVP when $\lambda$ in some interval. Our approach is based on Leray-Schauder nonlinear alternative. Particularly, we do not use the nonnegative assumption and monotonicity which was essential for the technique used in almost all existed literature on f.

Inductive Switching Noise Suppression Technique for Mixed-Signal ICs Using Standard CMOS Digital Technology

  • Im, Hyungjin;Kim, Ki Hyuk
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.4
    • /
    • pp.268-271
    • /
    • 2016
  • An efficient inductive switching noise suppression technique for mixed-signal integrated circuits (ICs) using standard CMOS digital technology is proposed. The proposed design technique uses a parallel RC circuit, which provides a damping path for the switching noise. The proposed design technique is used for designing a mixed-signal circuit composed of a ring oscillator, a digital output buffer, and an analog noise sensor node for $0.13-{\mu}m$ CMOS digital IC technology. Simulation results show a 47% reduction in the on-chip inductive switching noise coupling from the noisy digital to the analog blocks in the same substrate without an additional propagation delay. The increased power consumption due to the damping resistor is only 67% of that of the conventional source damping technique. This design can be widely used for any kind of analog and high frequency digital mixed-signal circuits in CMOS technology

Rapid Analysis of Melamine Content in Powdered and Liquid Milk Using Fourier Transform Infrared Spectroscopy

  • Wang, Jun;Jun, Soo-Jin;Li, Qing X.
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1199-1203
    • /
    • 2009
  • Melamine is a chemical intermediate to manufacture amino resins and plastics, which cannot be used as food additive since it can cause kidney stones. A qualitative determination method of melamine residue in powdered and liquid milk was developed using Fourier transform infrared (FTIR) spectroscopic technique. The calibration sets consisted of 21 standard melamine solutions, in which 1% trichloroacetic acid aqueous solution and acetonitrile (3:1, v/v) were used as solvent. The model was validated using 10 standard melamine solutions which were unused to build up the calibration set. Infrared (IR) absorbance peaks specific to almost all chemical groups in melamine molecule were shown in the spectral range between 1,100 and 1,800/cm. Combined partial least squares (PLS)-$2^{nd}$ derivative calibration model coupled with mean centering (MC) mathematical enhancement showed the highest correlation coefficients ($R^2$>0.99). In brief, the FTIR technique can be used for quantitative analysis of melamine in milk samples.