An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능 (Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head)

  • 정길순;이병곤
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

[논문철회]노인관련시설에서 조기반응형 스프링클러헤드의 유용성 ([Retracted]Evaluation of Early Suppression-Fast Response (ESFR) Sprinklers in Facilities and Residences for Elderly People)

  • 최영상;공예린;공하성
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.15-20
    • /
    • 2015
  • 이 연구는 노인관련시설에 스프링클러 설치유무와 종류에 따른 연기층 및 공기층의 온도변화와 연기층의 높이변화를 화재시뮬레이션을 통해 비교한 것으로 복사열은 거실에 표준반응형 헤드가 작동한 경우는 플래시오버 발생조건을 초과하였으나 조기반응형 헤드는 플래시오버가 발생되지 않는 것으로 나타났다. 인체표면의 경우도 조기 반응형 헤드가 작동하면 열유속의 최대값이 $2,293W/m^2$에 머물러 인체화상 위험조건인 $4,000W/m^2$ 이하가 되어 거주자가 열에 의해 인체화상은 입지 않는 것을 알 수 있다. 화재실의 최고온도는 연기층 및 공기층 모두 인명안전기준을 초과하였으나 일정시간 후 급격히 하강하여 인명안전기준에서 요구하는 온도 이하로 유지되는 것을 알 수 있었다. 연기층의 높이는 조기반응형 헤드가 작동하면 연기층을 1.1 m 이상으로 유지할 수 있어서 표준반응형 헤드가 작동한 경우보다 연기층 하강을 더 지연시킬 수 있음을 알 수 있다.

화재성장시나리오에 따른 스프링클러 헤드의 작동조건 (Activation Conditions of Sprinkler Head Considering Fire Growth Scenario)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.45-51
    • /
    • 2020
  • 본 연구에서는 스프링클러 헤드의 해석모델을 통해 화재성장모드별 스프링클러 작동시 연층기류의 열유동조건을 파악하고자 한다. 화원은 최대발열량 3 MW의 시간제곱의 화재성장을 가정하였다. 시험대상 스프링클러헤드는 작동온도 65~105 ℃, RTI 25~171 m1/2s1/2 범위의 표준형과 조기반응형 8종을 대상으로 한다. 연층기류의 온도와 감열부의 온도차는 화재성장이 느리고 스프링클러 헤드의 RTI값이 작을수록 감소하는 경향을 보였다. 스프링클러 헤드 작동 순간의 연층 기류 온도와 속도조건은 전체적으로 시험기준의 범위와 비교적 잘 일치하고 있으나 저성장 화재에서는 최저시험기준 이하의 온도와 속도조건에서 작동이 이루어질 수 있음을 파악하였다. 본 연구는 스프링클러 헤드의 작동에 대한 기초연구로서 시험기준의 신뢰성을 향상시키는데 기여할 수 있다.

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능 (Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head)

  • 정길순;이병곤
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.37-41
    • /
    • 1997
  • 스프링클러 소화설비는 화재가 발생하였을 때 자동적으로 감열, 작동하여 초기화재 진압을 목적으로 하는 소화설비로서 소화특성은 화재발생으로부터 소화가 시작되는 화재감지특성과 화재제어 및 진압에 대한 방사특성1) 으로 FRS2) 3)와 FMRC4)에서는 열응답의 민감도를 나타내는 반응시간지수(RTI)의 측정방법과 이론을 제시하였다. 반응시간지수는 스프링클러헤드의 작동에 필요한 충분한 열을 주위로부터 얼마나 빠른 시간내에 흡수 할 수 있는지를 나타내는 특성치로서 가열공기의 온도 및 속도에 의해 결정되며 값이 적을수록 헤드가 조기에 작동하게 된다. (중략)

  • PDF

공간용도별 위험등급기반의 스프링클러헤드 성능 설계기법의 국내적용 연구 (A Study on Introduction to Performance based Design of Sprinkler Installation on Risk Level for Individual Occupancy in Korea)

  • 이영재;박형주
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.1-10
    • /
    • 2012
  • 선진국에서는 다양한 건축용도의 위험등급을 분류하여 해당 위험등급의 수준에 적합한 방수패턴을 가진 스프링클러의 방수규격을 기준으로 용도별 위험등급 기반의 성능설계를 실시하고 있는 반면에, 국내에서는 건축공간용도의 거주밀도나 화재하중밀도가 표준화하고 있지 않아 위험등급조차 설정하지 않은 채 균일한 방수패턴을 가진 표준형 스프링클러 헤드를 일률적으로 적용하고 있는 실정이다. 이런 실정으로 인해 국내에서는 스프링클러의 방수패턴에 대한 요구사양이 다양하게 필요하지 않아 선진국과 같이 다양한 방수상수를 가지면서 방호면적을 달리하는 다양한 종류의 헤드 개발이 이루어지지 않고 있는 실정이다. 그러므로 국내의 주요 건축공간용도에 대한 화재하중밀도를 조사하여 표준 값을 제시하고 영국 LPC나 미국 NFPA에서 정하고 있는 위험등급별로 분류한 결과 크게 다르지 않음을 발견하였다. 따라서 공간용도별 위험등급 기반의 성능 설계를 우리나라에서 적용하기위한 기초적인 토대를 마련하고 국내 스프링클러 헤드개발환경을 개선하기 위한 오리피스와 방수상수를 다양화함으로써 특수한 고위험공간용도에서 효과적으로 적용 가능한 라지 드롭형, ELO형, 또는 ESFR형 등의 스프링클러 헤드 개발을 촉진하도록 유도하였다. 결론적으로 위험등급별로 다양하게 적용되는 스프링클러 헤드를 체계적으로 분류하여 국내 건축용도에 적용 가능한 최적의 방수패턴에 대한 기본사양을 정립하여 제시하였다.

풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구 (Study on the Operation Characteristics of Heat Detectors through Fire and Wind Tunnel Experiment)

  • Ryu, Hocheol;Kim, Doohyun
    • 한국재난정보학회 논문집
    • /
    • 제11권2호
    • /
    • pp.203-209
    • /
    • 2015
  • 열감지기는 화재시 발생되는 열을 감지하는 것으로 모든 소방대상물에 일반적으로 사용되는 자동화재탐지설비의 중요한 핵심 요소이다. 열감지기는 스포트(spot)형과 분포형으로 구분되며, 스포트형에는 차동식과 정온식이 있다. 이러한 열감지기는 실제 화재시 작동시간 및 작동온도 등 반응의 민감도에 따라 인명과 재산 손실에 큰 영향을 준다. 국내에서는 스프링클러 헤드제품에 응답시간지수를 도입하여 사용하고 있으나, 열감지기에 대해서는 현재 적용이 되어지지 않고 있으며, 반응의 민감도를 표시하는 응답시간지수의 도입이 필수적으로 본 연구에서는 국내 생산된 정온식 스포트형 열감지기와 다이아프램형 및 반도체 형식의 차동식 스포트형 열감지기에 대하여 풍동실험 및 화재실험을 통하여 응답시간지수, 작동시간, 작동온도 등에 대하여 연구하였다. 응답시간지수를 적용한 열감지기를 설치하여 신속한 경보로 인한 국민의 생명과 재산손실을 줄이는데 도움을 주고자 한다.

샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안 (A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse)

  • 안병국;김운형;양소진;함은구
    • 한국재난정보학회 논문집
    • /
    • 제16권3호
    • /
    • pp.421-429
    • /
    • 2020
  • 연구목적: 본 연구는 샌드위치패널 창고의 화재예방 및 현장소방대응력 제고를 위한 단계별 대응방안 제시를 목적으로 한다. 연구방법: 화재현장 관련 소방관 인터뷰와 소방전문가의 자문 및 방호성능 실험을 수행하여 현장대응력 강화를 위한 요소별 대책을 도출하였다. 연구결과: 창고 소방안전관리자용 화재안전관리 체크리스트 및 샌드위치패널 창고의 벽 방호용 스프링클러 설치기준을 제시하였다. 아울러 현장출동 소방관을 위한 샌드위치패널 창고 화재적용 표준작전절차를 수립하였다. 결론: 본 연구를 통하여 가연성 구조 창고의 화재 예방, 방호 및 진압에 대한 단계별 화재안전대책을 구축하였다.