• Title/Summary/Keyword: Standard reference material

Search Result 239, Processing Time 0.03 seconds

Uncertainty Analysis and Compensation of the Cell for Permittivity Measurement of Solid Materials (고체재료의 유전율 측정용 Cell의 불확도 분석과 보상)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • The commercial parallel plate electrodes system with guard-ring electrode have been widely used for measurement of dielectric constants of solid materials. And the specification of the electrodes system is about 1 % of measurement uncertainty. This measurement uncertainty is only estimated the error come from mechanical measurements such as the area of the electrodes and the gap between the electrodes except the error come from the air gap between the electrodes and dielectric specimen. Because it is impossible to measure the air gap. This study analyze the total measurement uncertainties of the commercial dielectric constant test cell using 3 kinds of Standard Reference Materials. As a results, the total measurement uncertainty is much bigger than 1 % and the most of the uncertainty can be reduced by compensation of the error values evaluated in this study.

SWNT-UHF Fusion Sensor for GIS Partial Discharge Detection (가스절연기기의 부분방전검출을 위한 SWNT-UHF 융합센서)

  • Lee, Sang-Wook;Chang, Yong-Moo;Baik, Seung-Hyun;Lee, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.120-120
    • /
    • 2010
  • To detect the PD events, we have studied a fusion sensor, the UHF sensor and the single-walled carbon nanotube(SWNT) gas sensor. We are accustomed to the UHF sensor which have employed to detect the partial discharges in apparatus GIS-like. But the SWNT gas sense is a newly way proposed to detect the partial discharges. In this study, we monitored not only the changes of the electrical conductance of the SWNT sensors in responding to the PD events but also the signal of the UHF sensor at the same time with IEC 60270 standard method for reference on the partial discharge events.

  • PDF

A Study on the Standard Joint Material and Reference Plane for the Standard of Construction in the Apartment - Joining Part between Gypsumboard and Windows - (공동주택 시공표준화를 위한 조립기준면 및 표준마무리재에 관한 연구 - 석고보드 마감재와 창호재의 접합부위를 중심으로 -)

  • Lim, Seok-Ho;Park, Keun-Soo;Lee, Ga-Kyung
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.31-38
    • /
    • 2009
  • In our country, the application of the design method of face to face dimension in wall-slab apartment has passed 10 years. So MC(Modular Coordination) design method has fixed in the design step to some degree. In Design and Work Execution of House the exclusive area of the apartment was calculated by face to face dimension. And the term of face to face dimension was known broadly to clients, construction company, etc. But design method of face to face dimension is not to simply extend the room size so far as wall depth in design process but to ensure the actual space should be considered with efficient use and assembly of building components. That is to say, Design method of face to face dimension is not to be defined by design step but to be related with construction and maintenance. However in construction process the point of face to face design method was not understood even now. So the purpose of this study was to extract the effect and question of face to face design method in construction process by survey of actual condition of structure and construction quality, and compare this result with existing construction method. The following project of this study is to survey of actual condition of interior components such as gypsum board, windows & doors etc. Therefore this study is to induce architectural long-life through architectural standardization construction and component's exchange, and, by the subject of the study on Apartment to have design guideline and basis for joining part between Gypsumboard and windows.

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Preparation of wastewater-based reference materials for heavy metal analysis and interlaboratory study (중금속분석용 폐수표준물질 제조 및 실험실간 비교평가)

  • Kim, Young-Hee;Song, Ki-Bong;Shin, Sun-Kyoung;Lee, Jung-Sub;Jeong, Gi-Taeg;Hong, Eun-Jin;Park, Jin-Ju;Yu, Suk-Min
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2010
  • In this study, the wastewater-based reference material (RM) was prepared and certified for 7 trace metal elements with evaluation of uncertainties. The RM was distributed to 25 laboratories for the interlaboratory comparison testing. The certified values and expanded uncertainties were derived using ISO guideline 35 and the standard uncertainties for homogenieties were 0.43~2.67% of certified values. The analytical results from the interlaboratory comparison testing showed normal distributions and the robust means from the interlaboratory comparison testing were higher than the certified values of the RM for all analytes.

Design and Fabrication of Micro-sensors Using CMOS Technology (CMOS 공정을 이용한 마이크로 센서의 설계 및 제작)

  • Lee, Sung-Pil;Lee, Ji-Gong;Chang, Choong-Won;Kim, Ju-Nam;Lee, Yong-Jae;Yang, Heung-Yol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.347-348
    • /
    • 2007
  • On-chip micro humidity sensor, using $CN_x$ films for the sensing material, was designed, simulated, and fabricated with Op amp based readout circuit and diode temperature sensors. To compensate the temperature and other gases, two methods were applied. One is wheatstone-bridge with reference FET that eliminates other undesirable chemical species, and the other is a diode temperature sensor to compensate the temperature effect. $CN_x$ film can be a new humidity sensing material, and has a strong potential to adapt to smart sensors or multi-sensors using MEMS or nano-technology. A particular design technology for integration of sensors and systems together was proposed that whole fabrication process could be achieved by a standard CMOS process.

  • PDF

Results of round robin test for specific surface area (비표면적 순회평가 결과)

  • Choi, Byung-Il;Kim, Jong-Chul;Woo, Sang-Bong
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.503-509
    • /
    • 2011
  • Specific surface area is becoming a very important factor when newly developed advanced nano-materials are evaluated. But there have been many differences in results when measuring specific surface areas, depending on the measuring equipments and analysis method. To verify the reliability of the specific surface area measurement device supplied within the country, Round Robin Test (RRT) has been done at 21 affiliated research institutes. As a result, it was found that several institute had problems in measuring of gas adsorption amount in measuring equipment, and this proved the need for certified reference material (CRM). Furthermore, it was also found that the results from BET analysis is easily swayed by the analyst's subjectivism, and the calculated results may differ up to 16% in case of CRM I depending on the selection range of BET analysis. So this showed that a standard guideline for BET constant C value and fitting correlation coefficient R is needed, to properly select range in BET analysis. The experience in RRT, distribution of CRM, and standardized procedure would result in improved reliability in industrial processes, and thus, would contribute to the quality management, the productivity improvement, the safety evaluation, and the new material development.

Development of 10 μmol/mol Hydrogen Sulfide Primary Standard Gas for Odor Measurements (악취측정용 10 μmol/mol 황화수소 표준가스 개발)

  • Kim, Yong-Doo;Bae, Hyun-Kil;Kim, Dalho;Oh, Sang-Hyub;Lee, Jin Hong;Lee, Sangil
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.46-51
    • /
    • 2018
  • Hydrogen sulfide from landfill and sewage treatment plant is a major odor component and causes many civil petitions. Rapidly developing industries release hydrogen sulfide, an odorous gas, to the atmosphere. This study aims to develop a $10{\mu}mol/mol$ concentration level hydrogen sulfide primary standard gas for odor measurement. The hydrogen sulfide gas was prepared at a nominal concentration of $10{\mu}mol/mol$ in nitrogen using the gravimetric method described in ISO 6142. Replicate standard gases were produced in 4 aluminium cylinders, and their concentrations were verified by GC-AED. The uncertainty of production was less than 0.50 %, and the variation of the 4 replicates was 0.22 %. The wall adsorption of hydrogen sulfide in cylinders was 0.10 % at 1500 psi, and the concentration was estimated to be long-term stable for one year. The relative expanded uncertainty of the preparation consistency, adsorption and long-term stability of this hydrogen sulfide standard gas was less than 1.05 % (95 % of confidence level, k=2).

Improvement of Analysis Methods for Fatty Acids in Infant Formula by Gas Chromatography Flame-Ionization Detector (GC-FID를 이용한 조제유류 중 지방산 분석법 개선 연구)

  • Hwang, Keum Hee;Choi, Won Hee;Hu, Soo Jung;Lee, Hye young;Hwang, Kyung Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • The purpose of this research is to improve analysis methods of determining the contents of fatty acids in infant formulas and follow-up formulas. A gas chromatography (GC) method was performed on a GC system coupled to flame ionization detector, with a fused silica capillary column (SP2560, 100 m×0.25 mm, 0.20 ㎛). The method was validated using standard reference material (SRM, NIST 1849a). Performance parameters for method validation such as specificity, linearity, limits of detection (LOD) and quantification (LOQ), accuracy and precision were examined. The linearity of standard solution with correlation coefficient was higher than 0.999 in the range of 0.1-5 mg/mL. The LOD and LOQ were 0.01-0.06 mg/mL and 0.03-0.2 mg/mL, respectively. The recovery using standard reference material was confirmed and the precision was found to be between 0.8% and 2.9% relative standard deviation (RSD). Optimized methods were applied in sample analysis to verify the reliability. All the tested products had acceptable contents of fatty acids compared with component specification for nutrition labeling. The result of this research will provide efficient experimental information and strengthen the management of nutrients in infant formula and follow-up formula.

DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS (규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가)

  • Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.1
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF