• Title/Summary/Keyword: Standard floor impact sources

Search Result 21, Processing Time 0.029 seconds

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources (실생활 충격소음을 통한 표준 바닥충격원의 실효성 검증)

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1117-1126
    • /
    • 2013
  • The standard impact sources, standardized to rate the sound insulation performance of floor structure, should simulate well the real floor impact sources, which is very important to grade the floor structure then to establish counter plan to improve the performance of floor. Recently the tire, the standard heavyweight impact source, has been discussed that the impact force is too big to represent the real impact force. And researches have been carried on the applicability as a substitute or a supplementary. In addition, tapping machine, the standard lightweight impact source, is also questionable if it is representative of real lightweight impact source. This study aims to examine the similarity of standard impact sources with living impact sources, comparing the physical characteristics such as impact force, frequency contents and sound level. The result showed that the physical characteristics of standard impact sounds were somewhat different with that of living impact sounds, and the standard sources couldn't be verified from this result. Later subjective evaluation should be followed to compare how the physical differences make relationship with the subjective differences.

Evaluation of Floor Impact Sound Isolation in a Dry Floor System (건식 바닥구조의 바닥충격음 차단성능 평가)

  • You, Jin;Ryu, Jong-Kwan;Jeon, Jin-Young;Lee, Chung-Hwa;Kim, Chul-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.950-953
    • /
    • 2005
  • Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.

  • PDF

Comparison of Standard Floor Impact Sources with a Human Impact Source (바닥충격음 측정용 표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Park, Jun-Hong;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.

Performance of floor coverings by impact sound (실 충격원에 대한 바닥마감재 성능 분석)

  • Chung, Jinyun;Im, Jungbin;Lee, Sungchan;Kim, Kyoungwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

Comparison of the Standard Floor Impact Source with the Human Impact Source (표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.804-807
    • /
    • 2005
  • The characteristics of the standard floor impact sources and the human impact source were investigated. First, the mechanical impedance of the each source was evaluated. Second, the impact force exposure levels and impact sounds level driven by the each source were measured. The results showed that the mechanical impedance and impact force exposure level of the impact ball are the most similar to those of the human impact source among the standard impact sources.

  • PDF

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Subjective response evaluation items for floor impact noise using various impactors (다양한 충격원에 대한 바닥충격음 주관반응 평가항목 분석)

  • Hyeon-Ku Park;Seonhwa Lee;Minjeong Song
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.584-593
    • /
    • 2023
  • This study attempted to develop repetitive impact sources similar to real-life floor impact noise and to find an assessment approach corresponding to this new impact source. The necessity for the development of the new impact source arises from the fact that issues related to floor impact noise in actual residential buildings mainly stem from children running. However, the standard impact sources which have been used for measuring and evaluating floor impact noise are of single-impulse type, which differs from the actual problematic impact sources. The study encompassed 18 evaluation items, and the results suggest that items applicable for assessing floor impact noise include psychological effects (annoying, becoming angry), disturbances to daily life (interference with sleep, disruption of relaxation), and physiological effects (elevated blood pressure). These items can be employed individually and, depending on the type of evaluation for floor impact noise, can be selectively utilized. By doing so, more comprehensive evaluations of auditory experiments in laboratories or assessments of residential noise in living environments related to floor impact noise could be conducted.

A Study on the Characteristic and Reproducibility of Floor Impact Sound Source (바닥충격음원의 특성과 재현성에 관한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.23-31
    • /
    • 2003
  • From 1998, the number of household who live in apartment house outnumber that of household live in detached dwelling by 0.3% in Korea. As walls and floors are shared with neighbourhood in apartment houses, percent complaints to the impact noise from the upper floor was so high that it represents an important factor in apartment indoor noise. And the rate is closely correlate with children's running, playing and jumping. In this study, comparisons of standard impact source, such as Tapping Machine and Bang Machine, with real life impact sources were made in order to investigate acoustical characteristics between them. Also reproducibility tests for impact sound sources were carried out.

Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources (중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구)

  • Yoo, Seung-Yup;Yeon, Jun-Oh;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.