• Title/Summary/Keyword: Standard evaluation

Search Result 5,518, Processing Time 0.04 seconds

Quantification of Protein and Amylose Contents by Near Infrared Reflectance Spectroscopy in Aroma Rice (근적외선 분광분석법을 이용한 향미벼의 아밀로스 및 단백질 정량분석)

  • Kim, Jeong-Soon;Song, Mi-Hee;Choi, Jae-Eul;Lee, Hee-Bong;Ahn, Sang-Nag
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.603-610
    • /
    • 2008
  • The principal objective of current study was to evaluate the potential of near infrared reflectance spectroscopy (NIRS) as a non-destructive method for the prediction of the amylose and protein contents of un-hulled and brown rice in broad-based calibration models. The average amylose and protein content of 75 rice accessions were 20.3% and 7.1%, respectively. Additionally, the range of amylose and protein content were 16.6-24.5% and 3.8-9.3%, respectively. In total, 79 rice germplasms representing a wide range of chemical characteristics, variable physical properties, and origins were scanned via NIRS for calibration and validation equations. The un-hulled and brown rice samples evidenced distinctly different patterns in a wavelength range from 1,440 nm to 2,400 nm in the original NIR spectra. The optimal performance calibration model could be obtained by MPLS (modified partial least squares) using the first derivative method (1:4:4:1) for un-hulled rice and the second derivative method (2:4:4:1) for brown rice. The correlation coefficients $(r^2)$ and standard error of calibration (SEC) of protein and amylose contents for the un-hulled rice were 0.86, 2.48, and 0.84, 1.13, respectively. The $r^2$ and SEC of protein and amylose content for brown rice were 0.95, 1.09 and 0.94, 0.42, respectively. The results of this study suggest that the NIRS technique could be utilized as a routine procedure for the quantification of protein and amylose contents in large accessions of un-hulled rice germplasms.

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

The Studies on various Causes of Cleanness Defects with in Raw Silk. (생사의 대중절 발생원인 구명에 관한 연구)

  • 최병희;마석일
    • Journal of Sericultural and Entomological Science
    • /
    • no.12
    • /
    • pp.21-36
    • /
    • 1970
  • This studies have been carried out to 3nd various causes of cleanness defects on raw silk which has been increased since 1967 in Korea, so that this treatise may be a guide inform action to improve such a defect in future. The cocoon treatment for the proposed work was carried starting with in worst condition to find the critical limit of degrading through such a work. And various analysis have been also worked out using the annual silk testing data past a few years. The results obtained are as follows. 1. There was a great relationship between cleanness and neatness result. 2. Cleanness result is greatly influenced by mounting conditions and handling of cocoons, which brought 40 percent lower as cleanness result than standard ones in which caused minor defects, especially loops and split ends, so the bad mounting conditions and handling of fresh cocoons degraded raw silk from 4A grade to E. 3. The use of good water quality brought the difference of 1.04 percent in cleanness result rather than the use of bad one. 4. Well technical work brought the difference of 0.86 percent in cleanness result rather than poor technical work. 5, Satisfactory cocoon drying installation brought the difference of 1.97 percent in cleanness result rather than insufficient one. 6. Automatic reeling machine marked lower 1,55 percent in cleanness result than multi-end reeling machine. 7. The degrading of cleanness result from 1965 year silk to 1969 year silk marked 1.99 percent, which almost responds to the degrading rate from good to poor cocoon drying installed cleanness results. In view of this result, nowadays, insufficient cocoon drying installation may be main factor to be worse cleanness result of Korean raw silk. 8. The factors of cleanness defect in raw silk once supplied with cocoon into factory are water quality, technique evaluation, cocoon drying capacity and s: reeling machine. The relationship between cleanness result and above factors are as follows. cleanness result=neatness result+1.6-1.04(1-a)-1.97(1-b)-0.86(1-c)+1.55${\times}$d a: The successive we ratio of water quality (0\longrightarrowl) b: The successive ratio of satisfactory cocoon drying installation (0\longrightarrowl) c: The successive ratio of well technical work (0\longrightarrowl) d: 1 in case multi-end reeling machine o in case automatic reeling machine 9, It is not admitted that there is heavy relationship between cleanness occurrence and nonbreaking reel ability. That mal$.$ be sowed with silk reeling technique. 10. The bad mounting conditions caused the worse result on the cocoon quality as much as cleanness. 11. Besides mounting conditions, there may be another factors affecting on the low reel ability of cocoons in Korea.

  • PDF

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Residual Characteristics of Bistrifluron and Chlorantraniliprole in Strawberry (Fragaria ananassa Duch.) for Establishing Pre-Harvest Residue Limit (생산단계 잔류허용기준 설정을 위한 딸기 중 bistrifluron과 chlorantraniliprole의 잔류 특성 연구)

  • Lee, Jae Won;Kim, Ji Yoon;Kim, Hee gon;Hur, Kyung Jin;Kwon, Chan Hyeok;Hur, Jang Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • BACKGROUND: Pesticide residue analysis is essentially required for safety evaluation of agricultural products. Bistrifluron and chlorantraniliprole have been currently considered as potentials to deeply evaluate their residues in agricultural products because they are frequently found in strawberry. This work was performed to investigate the residual patterns of bistrifluron and chlorantraniliprole in strawberry after harvest. METHODS AND RESULTS: Strawberry was treated with bistrifluron and chlorantraniliprole 0, 1, 2, 3, 5, 7 and 10 days before harvest under greenhouse conditions. The strawberry samples were subjected to solvent and solid phase extractions followed by LC-MS/MS analysis. There covery percentages of bistrifluron and chlorantraniliprole for tified in the control samples ranged from approximately 82 to 103% with the method limit of 0.005 mg/kg. The concentrations of bistrifluron and chlorantraniliprole in strawberry samples decreased significantly in 10 days after treatment, giving the safety levels of 0.04 to 0.06 mg/kg at 10 days after application, as considered maximum residue limit. The half-lives of bistrifluron and chlorantraniliprole based on first order kinetics were determined to 6.3 days and 6.4 days, respectively. CONCLUSION: Bistrifluron and chlorantraniliprole are suggested to use in strawberry 10 days before harvest to reach residual safety levels.

Monitoring of Aflatoxins in Medicinal Herbs (유통 생약재의 아플라톡신 모니터링)

  • Kim, Yong-Hoon;Kang, Han-Saem;Oh, Sun-Woo;Lee, Hwa-Jung;Kim, Mi-Gyeong;Chung, So-Young;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Lee, Ji-Won;Kim, Young-Seon;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • This study was conducted to monitor aflatoxins in various medicinal herbs, providing available data for the safety of those products. To monitor aflatoxins in medicinal herbs, a total of 400 samples of 40 different herbs were collected in commercial retailers in Seoul, Daejeon, Gwangju, Daegu, and Busan from March to August, 2008. The samples that passed the sensory evaluation were tested for aflatoxins. Aflatoxins in samples were analyzed by HPLC-florescence coupled with photochemical enhancement. Samples were extracted with 70% methanol and then diluted to the appropriate concentration. A refining process was performed using an immunoaffinity column. The analytical method used in this study was validated. The $R^2$ value for aflatoxin $B_1$ was 0.99946, and the detection range was from 0.25 to 10.0 ng/mL. The accuracy of the analysis was ranged from 83.2% to 101.8%. The relative standard deviation (RSD) in the aflatoxin $B_1$ analysis was 3.4%, demonstrating the precision of this method. In addition, the detection limit and quantitative analysis limit of aflatoxin $B_1$ was $0.53\;{\mu}g/kg$ and $1.76\;{\mu}g/kg$, respectively. These results indicated that the analytical method used in this study was appropriate. The results of HPLC showed that 1% (4 samples) of the samples may contain aflatoxins. The concentration of quantified aflatoxin was $2.3\;{\mu}g/kg$ for both Quisqualis fructus and Remotiflori radix samples. The other samples were below the limit of quantification. Moreover, the concentration of aflatoxin $B_1$ which is made by specific fungi were below the level of regulation. Only 20% of aflatoxin $B_1$ were transferred to hot water. Therefore, the levels of aflatoxins in medicinal herbs were considered to be safe especially considering the aflatoxin transfer ratio.

Novel Real Time PCR Method for Detection of Plasmodium vivax (새로운 Real Time PCR 방법을 통한 Malaria(Plasmodium vivax)의 검출)

  • Ki, Yeon-Ah;Kim, So-Youn
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Malaria is a re-emerging infectious disease that is spreading to areas where it had been eradicated, such as Eastern Europe and Central Asia. To avoid the mortality from malaria, early detection of the parasite is a very important issue. The peripheral blood smear has been the gold standard method for the diagnosis of malaria infection. Recently, several other methods have been introduced for quantitative detection of malaria parasites. Real time PCR that employs fluorescent labels to enable the continuous monitoring of PCR product formation throughout the reaction has recently been used to detect several human malaria parasites. 18S rRNA sequences from malaria parasites have been amplified using Taqman real time PCR assay. Here, a SYBR Green-based real time quantitative PCR assay for the detection of malaria parasite-especially, Plasmodium vivax - was applied for the evaluation of 26 blood samples from Korean malaria patients. Even though SYBR Green-based real time PCR is easier and cheaper than Taqman-based assay, SYBR Green-based assay cannot be used because 18S rRNA cannot be specifically amplified using 1 primer set. Therefore, we used DBP gene sequences from Plasmodium vivax, which is specific for the SYBR Green based assays. We amplified the DBP gene from the 26 blood samples of malaria patients using SYBR Green based assay and obtained the copy numbers of DBP genes for each sample. Also, we selected optimal reference gene between ACTB and B2M using real time assay to get the stable genes regardless of Malaria titer. Using selected ACTB reference genes, we successfully converted the copy numbers from samples into titer, ${\sharp}$ of parasites per microliter. Using the resultant titer from DBP based SYBER Green assay with ACTB reference gene, we compared the results from our study with the titer from Taqman-based assay. We found that our results showed identical tendency with the results of 18S rRNA Taqman assay, especially in lower titer range. Thus, our DBP gene-utilized real time assay can detect Plasmodium vivax in Korean patient group semi-quantitatively and easily.

Quantitative Analysis of Amylose and Protein Content of Rice Germplasm in RDA-Genebank by Near Infrared Reflectance Spectroscopy (근적외선 분광분석법을 이용한 벼 유전자원의 아밀로스 함량과 단백질 함량 정량분석)

  • Kim, Jeong-Soon;Cho, Yang-Hee;Gwag, Jae-Gyun;Ma, Kyung-Ho;Choi, Yu-Mi;Kim, Jung-Bong;Lee, Jeong-Heui;Kim, Tae-San;Cho, Jong-Ku;Lee, Sok-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.217-223
    • /
    • 2008
  • Amylose and protein contents are important traits determining the edible quality of rice, especially in East Asian countries. Near-Infrared Reflectance Spectroscopy (NIRS) has become a powerful tool for rapid and nondestructive quantification of natural compounds in agricultural products. To test the practically of using NIRS for estimation of brown rice amylose and protein contents, the spectral reflectances ($400{\sim}2500\;nm$) of total 9,483 accessions of rice germplasm in Rural development Administration (RDA) Genebank ere obtained and compared to chemically determined amylose and protein content. The protein content of tested 119 accessions ranged from 6.5 to 8.0% and 25 accessions exhibited protein contents between 8.5 to 9.5%. In case of amylose content, all tested accessions ranged from 18.1 to 21.7% and the grade from 18.1 to 19.9% includes most number of accessions as 152 and 4 accessions exhibited amylose content between 20.5 to 21.7%. The optimal performance calibration model could be obtained from original spectra of brown rice using MPLS (Modified Partial Least Squares) with the correlation coefficients ($r_2$) for amylose and protein content were 0.865 and 0.786, respectively. The standard errors of calibration (SEC) exhibited good statistic values: 2.078 and 0.442 for amylose and protein contents, respectively. All these results suggest that NIR spectroscopy may serve as reputable and rapid method for quantification of brown rice protein and amylose contents in large numbers of rice germplasm.

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

CLINCAL ANALYSIS OF SKELETAL STABILITY AFTER BSSRO FOR CORRECTION OF SKELETAL CLASS III MALOCCLUSION PATIENTS WITH ANTERIR OPEN BITE (전치부 개방교합을 동반한 골격성 제3급 부정교합 환자에 대한 양측 하악지 시상분할 골절단술후 안정성에 관한 임상적 분석)

  • Kim, Hyun-Soo;Kwon, Tae-Geon;Lee, Sang-Han;Kim, Chin-Su;Kang, Dong-Hwa;Jang, Hyun-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.152-161
    • /
    • 2007
  • This study was conducted to patients visited oral maxillo-facial surgery, KNUH and the purpose of the study was to assess skeletal and dento-alveolar stability after surgical-orthodontic correction treated by skeletal Class III malocclusion patients with open bite versus non-open bite. This retrospective study was based on the examination of 40 patient, 19 males and 21 females, with a mean age 22.3 years. The patients were divided into two groups based on open bite and non-open bite skeletal Class III malocclusion patients. The cephalometric records of 40 skeletal Class III malocclusion patients (open bite: n = 18, non-open bite: n = 22) were examined at different time point, i.e. before surgery(T1), immediately after surgery(T2), one year after surgery(T3). Bilateral sagittal split ramus osteotomy was performed in 40 patients. Rigid internal fixation was standard method used in all patient. Through analysis and evaluation of the cephalometric records, we were able to achieve following results of post-surgical stability and relapse. 1. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in maxillary occlusal plane angle of pre-operative stage(p>0.05). 2. Mean vertical relapses of skeletal Class III malocclusion patients with open bite were $0.02{\pm}1.43mm$ at B point and $0.42{\pm}1.56mm$ at Pogonion point. In skeletal Class III malocclusion patients with non-open bite, $0.12{\pm}1.55mm$ at B point and $0.08{\pm}1.57mm$ at Pogonion point. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in vertical relapse(p>0.05). 3. Mean horizontal relapses of skeletal Class III malocclusion patients with open bite were $1.22{\pm}2.21mm$ at B point and $0.74{\pm}2.25mm$ at Pogonion point. In skeletal Class III malocclusion patients with non-open bite, $0.92{\pm}1.81mm$ at B point and $0.83{\pm}2.11mm$ at Pogonion point. There was no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in horizontal relapse(p>0.05). 4. There were no significant statistical differences between open bite and non-open bite with skeletal Class III malocclusion patients in post-surgical mandibular stability(p>0.05). and we believe this is due to minimized mandibular condylar positional change using mandibular condylar positioning system and also rigid fixation using miniplate 5. Although there was no significant relapse tendency observed at chin points, according to the Pearson correlation analysis, the mandibular relapse was influenced by the amount of vertical and horizontal movement of mandibular set-back(p=0.05, r>0.304).