• 제목/요약/키워드: Standard Steel Connections

검색결과 38건 처리시간 0.022초

Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동 (Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams)

  • 주재형;채승윤;김선규;김우재;전호민;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF

철근 콘크리트 보-기둥 외측 접합부에 적용된 강섬유의 효과에 관한 실험연구 (An Experimental Study on the Effects of Steel Fibers used at R/C Exterior Joints)

  • 최기봉;오종한;김재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.188-193
    • /
    • 1998
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of lateral confinement and fiber reinforcement of joint area were investigated. It was concluded ; (1) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by pull-out of hooked bars; and (2) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers. Application of steel fibers to exterior joints seems to be an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in exterior beam-column connections.

  • PDF

파형강판 이음부의 강도 및 응력분포특성에 관한 연구 (Strength and Stress Distribution Behavior for the Connections of Corrugated Steel Plates)

  • 황원섭;강승표;위영민
    • 한국강구조학회 논문집
    • /
    • 제16권3호통권70호
    • /
    • pp.365-375
    • /
    • 2004
  • 이 연구에서는 FEM 해석을 통하여 파형강판 이음부의 강도 및 응력분포 특성에 관한 축방향 겹침길이 및 볼트간격의 영향 등을 검토하였다. 파형강판의 항복강도비($P/P_y$) 및 항복 후의 강도상승률은 축방향 겹침길이가 30mm일 때 가장 유리하게 되며, 현행의 제작기준에 의한 겹침길이는 매우 안전측의 값이 된다. 또한 파형강판 이음부의 강도특성은 볼트배치 방법에 따라 차이가 있는 것으로 나타났다. 즉, 볼트가 지그재그로 배치되어있는 표준형의 경우에는 주로 원둘레방향의 연단거리만이 강도에 영향을 미치게 되며, 볼트가 일렬로 배치되어있는 대골형의 경우에는 원둘레방향 연단거리와 볼트중심간격 모두 강도특성에 영향을 미치게 된다. 이 연구에서는 이상의 해석결과로부터 구한 강도특성 및 응력분포특성을 기초로 하여 현행의 파형강판 이음부 제작기준에 대한 타당성을 검토하였다.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

BIM 기반의 철골접합부 모델링 자동화에 관한 연구 (A Study on the Automation of the Connection modeling for Steel Structures based on BIM)

  • 엄진업;신태송
    • 한국강구조학회 논문집
    • /
    • 제22권1호
    • /
    • pp.99-108
    • /
    • 2010
  • 본 연구는 구조상세설계와 모델링 단계에서 활용 가능한 철골 접합부 모델링 자동화 모듈의 개발을 목적으로 한다. 이를 위해 접합부의 구조해석 결과를 3D 모델링의 입력 변수와 표준접합상세지침을 고려하여 라이브러리 D/B로 구축하였다. 구축된 라이브러리 D/B를 접합부 3D 모델링 단계에서 활용하기 위하여 상용 S/W에서 제공하는 OpenAPI 함수를 이용하여 접합부 자동 생성 모듈을 개발하였다. 개발된 모듈을 검증하기 위해 6층 규모의 철골 오피스 구조물을 대상으로 접합부 모델링을 수행하였으며, 접합부 모델링 과정에 대해 기존 프로세스와 연구 프로세스의 비교를 통해 적용성과 효율성을 검증하였다.

Effects of near-fault loading and lateral bracing on the behavior of RBS moment connections

  • Yu, Qi-Song Kent;Uang, Chia-Ming
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.145-158
    • /
    • 2001
  • An experimental study was conducted to evaluate the effects of loading sequence and lateral bracing on the behavior of reduced beam section (RBS) steel moment frame connections. Four full-scale moment connections were cyclically tested-two with a standard loading history and the other two with a near-fault loading history. All specimens reached at least 0.03 radian of plastic rotation without brittle fracture of the beam flange groove welds. Two specimens tested with the nearfault loading protocol reached at least 0.05 radian of plastic rotation, and both experienced smaller buckling amplitudes at comparable drift levels. Energy dissipation capacities were insensitive to the types of loading protocol used. Adding a lateral bracing near the RBS region produced a higher plastic rotation; the strength degradation and buckling amplitude were reduced. A non-linear finite element analysis of a one-and-a-half-bay beam-column subassembly was also conducted to study the system restraint effect. The study showed that the axial restraint of the beam could significantly reduce the strength degradation and buckling amplitude at higher deformation levels.

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

The practice of blind bolting connections to structural hollow sections: A review

  • Barnett, T.C.;Tizani, W.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.1-16
    • /
    • 2001
  • Due to aesthetic, economic, and structural performance, the use of structural hollow sections as columns in both continuous moment resisting and nominally pinned construction is attractive. Connecting the beams to these sections is somewhat problematic as there is no access to the interior of the section to allow for the tightening of a standard bolt. Therefore, bolts that may be tightened from one side, i.e., blind bolts, have been developed to facilitate the use of site bolting for this arrangement. This paper critically reviews available information concerning blind bolting technology, especially the performance of fasteners in shear, tension, and moment resisting connections. Also provided is an explanation of the way in which the results have been incorporated into design guidance covering the particular case of nominally pinned connections. For moment resisting connections, it is concluded that whilst the principle has been adequately demonstrated, sufficient data are currently not available to permit the provision of authoritative design guidance. In addition, inherent flexibilities in the connections mean that performance equivalent to full strength and rigid is unlikely to be achievable: a semicontinuous approach to frame design will therefore be necessary.

Fatigue property analysis of U rib-to-crossbeam connections under heavy traffic vehicle load considering in-plane shear stress

  • Yang, Haibo;Qian, Hongliang;Wang, Ping
    • Steel and Composite Structures
    • /
    • 제38권3호
    • /
    • pp.271-280
    • /
    • 2021
  • In this study, the fatigue property of U rib-to-crossbeam connections in orthotropic steel bridge (OSB) crossbeams under heavy traffic vehicle load was investigated considering the effects of in-plane shear stress. The applicability of an improved structural stress (ISS) method was validated for the fatigue behavior analysis of nonwelded arc-shaped cutout regions in multiaxial stress states. Various types of fatigue testing specimens were compared for investigating the equivalent structural stress, fatigue crack initiation positions, and failure modes with the unified standards. Furthermore, the implications of OSB crossbeams and specified loading cases are discussed with respect to the improved method. The ISS method is proven to be applicable for analyzing the fatigue property of nonwelded arc-shaped cutout regions in OSB crossbeams. The used method is essential for gaining a reliable prediction of the most likely failure modes under a specific heavy traffic vehicle load. The evaluated results using the used method are proven to be accurate with a slighter standard deviation. We obtained the trend of equivalent structural stress in arc-shaped cutout regions and validated the crack initiation positions and propagation directions by comparing them with the fatigue testing results. The implications of crossbeam spans on fatigue property are less significant than the effects of crossbeams.

강섬유 보강 초고강도 콘크리트의 확대 타설을 통한 기둥 하중 전달 성능 향상 (Improved Transmission of UHSC Column Loads by Puddling of Fiber Reinforced UHSC)

  • 이주하;양준모;이승훈;윤영수
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.209-216
    • /
    • 2007
  • 본 연구는 강섬유 보강 초고강도 콘크리트가 적용된 슬래브-기둥 접합부의 구조적 특성을 파악하였다. 2개의 슬래브-기둥 시험체와 4개의 독립 기둥 시험체의 기둥 하중 전달 실험이 수행되었다. 기둥 하중 실험 수행시, 슬래브-기둥 접합부의 실제 구속 상태를 고려하기 위해 슬래브 하중을 적용하였다. 주 변수로는 강섬유 보강 초고강도 콘크리트의 확대 타설이며, 이에 더하여 슬래브의 접합부 구속 효과, 강섬유 보강, 그리고 접합부의 콘크리트 강도 등이 실험을 통해 파악되었다. 또한, ACI Code(2005)와 CSA Standard(2004)의 예측식과 실험 결과를 비교하였다. 슬래브-기둥 접합부를 통한 기둥 하중 전달에 대한 강섬유 보강 초고강도 콘크리트의 효과를 실험을 통해 확인하였다.