Improved Transmission of UHSC Column Loads by Puddling of Fiber Reinforced UHSC  

Lee, Joo-Ha (Dept. of Civil and Environmental and Architectural Engineering, Korea University)
Yang, Jun-Mo (Dept. of Civil and Environmental and Architectural Engineering, Korea University)
Lee, Seung-Hoon (Institute of Tech., Samsung Engineering & Construction Co., Ltd.)
Yoon, Young-Soo (Dept. of Civil and Environmental and Architectural Engineering, Korea University)
Publication Information
Journal of the Korea Concrete Institute / v.19, no.2, 2007 , pp. 209-216 More about this Journal
Abstract
This study reports on the structural characteristics of slab-column connections using fiber-reinforced ultra-high-strength concrete (UHSC). Compression tests were performed on two slab-column and four isolated column specimens. In the column load tests, slab loads were also applied on the slab-column specimens so that the actual confinement condition at the slab-column joint was considered. The main parameter investigated was the "puddling" of fiber-reinforced UHSC. This paper also investigates the effects of some parameters, such as confinement of slab concrete, steel fibers, and concrete strength of the joint, related to the ability of the slab-column specimens and isolated column specimens without the surrounding slab to transmit axial loads from the UHSC columns through slab-column connections. Furthermore, the ACI Code (2005) and the CSA Standard (2004) are compared to the experimental results. The beneficial effects of the puddling of fiber-reinforced UHSC on the transmission of column loads through slab-column connections are demonstrated.
Keywords
ultra-high-strength concrete; slab-column connection; axial loads; steel fibers;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ACI 318-05 and ACI 318R-05, Building Code RequireMents for Structural Concrete and Commentary, American Concrete Institute, Farmington Hill, Michigan, 2005, 430pp
2 CSA A23.3-04, Design of Concrete Structures, Canadian Standards Association (CSA), Mississauga, Ontario, 2004, 249pp
3 Bianchini, A. C., Woods, R. E., and Kesler, C. E., 'Effect of Floor Concrete Strength on Column Strength', ACI Journal, Vol.31, No.11, 1960, pp.1149-1169
4 Ospina, C. E. and Alexander, S. D. B., 'Transmission of Interior Concrete Column Loads Through Floors', Journal of Structural Engineering, ASCE, Vol.124, No.6, 1998, pp. 602-610   DOI   ScienceOn
5 Adebar, P., Mindess, S., St-Pierre, D., and Olund, B., 'Shear Tests of Fiber Concrete Beams Without Stirrups', ACI Structural Journal, Vol.94, No.1, 1997, pp.68-76
6 Mindess, S., Adebar, P., and Henley, J., 'Testing Of fiber Reinforced Structural Concrete Elements', Proceedings of ACI International Conference on High-Performance Concrete: Design and Materials and Recent Advances in Concrete Technology, SP-172, V. M. Malhotra, ed., American Concrete Institute, Farmington Hill, Michigan, 1997, pp. 495-515