• 제목/요약/키워드: Standard Penetration Depth

검색결과 78건 처리시간 0.019초

피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구 (A Study on the Determination of Depth of Soft Ground by Cone Resistance)

  • 신윤섭;김민철;김연정;김영웅
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

인천지역의 동결깊이산정에 관한 연구 (A study of Determination of Frost penetration Depth in incheon Area)

  • 김희두;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.5-6
    • /
    • 2015
  • Recently, freezing index of frost penetration depth estimation used in Korea is applied according to the standard, published by MOLIT in 2003. However, it is difficult to consider can not be determined to standard reflects weather conditions in accordance with the current climate warming or abnormally high temperature. Also the temperature should be considered local variables because heavy local gap. Therefore, this study is through the freezing index presented in MOLIT's code by calculating the frost penetration depth determining whether the adequacy and conducted a study to apply in the field. As a result, when the Elevation 100m to standard in Incheon frost penetration depth is found to be 50.8cm.

  • PDF

와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析) (Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing)

  • 정태언;장기옥;박대영
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

표준관입시험 간격 결정을 위한 개념적 알고리즘 (A Conceptual Algorithm for Determining the Spacing of Standard Penetration Test Spots.)

  • 하비마나;이동훈;한경보;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.185-186
    • /
    • 2015
  • The Standard penetration test determines the type of soil according to soil bearing capacity, and this classifies the subsoil into many layers. Construction project managers are willing to know the depth of the present types of subsoil on site in order to make plans on earthwork stage during excavation. However the standard penetration test may not provide accurate information on subsoil type due to incorrect spacing. To solve this problem, this study propose a conceptual algorithm for determining the spacing of standard penetration test spots to essentially tests relevant locations on which to be applied the standard penetration test. This provides the acquirement of the accurate layered model volume of earthwork revised into geological columnar section. This algorithm will determine the appropriate standard penetration test spots spacing on a given size of site to optimize the accuracy of the earthwork volume, time and cost.

  • PDF

Estimation of Penetration Depth Using Acceleration Signal Analysis for Underwater Free Fall Cone Penetration Tester

  • Seo, Jung-min;Shin, Changjoo;Kwon, OSoon;Jang, In Sung;Kang, Hyoun;Won, Sung Gyu
    • 한국해양공학회지
    • /
    • 제34권3호
    • /
    • pp.202-207
    • /
    • 2020
  • A track-type underwater construction robot (URI-R) was developed by the Korea Institute of Ocean Science & Technology. Because URI-R uses tracks to move on the seabed, insufficient ground strength may hinder its movement. For smooth operation of URI-R on the seabed, it is important to determine the geotechnical properties of the seabed. To determine these properties, standard penetration test (SPT), cone penetration test (CPT), and sampling are used on land. However, these tests cannot be applied on the seabed due to a high cost owing to the vessel, crane, sampler, and analysis time. To overcome these problems, a free fall cone penetration tester (FFCPT) is being developed. The FFCPT is a device that acquires the geotechnical properties during impact/penetration/finish phases by free fall in water. Depth information is crucial during soil data acquisition. As the FFCPT cannot measure the penetration depth directly, it is estimated indirectly using acceleration. The estimated penetration depth was verified by results of real tests conducted on land.

Spatial interpolation of geotechnical data: A case study for Multan City, Pakistan

  • Aziz, Mubashir;Khan, Tanveer A.;Ahmed, Tauqir
    • Geomechanics and Engineering
    • /
    • 제13권3호
    • /
    • pp.475-488
    • /
    • 2017
  • Geotechnical data contributes substantially to the cost of engineering projects due to increasing cost of site investigations. Existing information in the form of soil maps can save considerable time and expenses while deciding the scope and extent of site exploration for a proposed project site. This paper presents spatial interpolation of data obtained from soil investigation reports of different construction sites and development of soil maps for geotechnical characterization of Multan area using ArcGIS. The subsurface conditions of the study area have been examined in terms of soil type and standard penetration resistance. The Inverse Distance Weighting method in the Spatial Analyst extension of ArcMap10 has been employed to develop zonation maps at different depths of the study area. Each depth level has been interpolated as a surface to create zonation maps for soil type and standard penetration resistance. Correlations have been presented based on linear regression of standard penetration resistance values with depth for quick estimation of strength and stiffness of soil during preliminary planning and design stage of a proposed project in the study area. Such information helps engineers to use data derived from nearby sites or sites of similar subsoils subjected to similar geological process to build a preliminary ground model for a new site. Moreover, reliable information on geometry and engineering properties of underground layers would make projects safer and economical.

보수용 모르타르의 강도 및 투과특성에 관한 연구 (An Experimental Study on the Strength and Permeability Characteristics of Repair Mortar)

  • 백신원
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.105-109
    • /
    • 2003
  • Structure surfaces damaged due to many causes are repaired by several special mortars. But wide studies about the permeability of these mortars were rarely conducted. In this study compressive strength test, flexural strength test and bond strength test of these mortars were conducted. And chloride ion penetration test was also conducted to explore the permeability charcteristics of selected repair mortars. This test was carried out following the standard ASTM C1202-91. Colouriemtric penetration depth can be drawn from these test results using a relationship equation between colourimetric penetration depth and charge passed which C. Andrade suggested. Diffusion coefficient can be calculated by CTH rapid method. To the end, the present study can provide a firm base for the application of repair mortars to concrete structures.

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 장서용;김종렬;신윤섭;마봉덕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.163-170
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과, 선행압밀하중, 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 qc=(1.09~1.63)N, 선행압밀하중을 고려한 결과 qc=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치(qc)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 $10kgf/cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 $65{\sim}70kgf/cm^2$ 의 값을 나타내었다.

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 김연정;김남호;신윤섭
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.261-269
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과(N치), 선행압밀하중(pc), 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 $q_c$=(1.09~1.63)N, 선행압밀하중을 고려한 결과 $q_c$=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 10kgf/$cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 65~70.0kgf/$cm^2$의 값을 나타내였다.

  • PDF

GIS를 이용한 대규모 매립지반의 액상화발생가능성 평가 (Assessment of Potential for Liquefaction in the Large Reclamation Site Using GIS)

  • 김홍택;유시동;박사원;이형규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1512-1519
    • /
    • 2005
  • In this study, the potential for liquefaction in the Incheon international airport was calculated by appling the standard penetration test data and laboratory test data to the modified Seed & Idriss(2001) method. The analysis was performed on the non-plastic silty layer and silty sand layer which within the depth of 20m, below 20 of the standard penetration value(N), and the ground water level. Also, each set of data was mapped by using GIS(geographic information systems) and the factor of safety for the potential for liquefaction was obtained by overlapping those layers. As a result, it was found that there exist potential hazard zone for the liquefaction partially. So, the additional detailed assessments for those are thought to be necessary.

  • PDF