• Title/Summary/Keyword: Standard Indicator

Search Result 415, Processing Time 0.03 seconds

ODFM-Based Adaptive Channel Estimation Algorithms for IEEE 802.11ad WLAN

  • Nguyen-Thi, My-Kieu;Kim, Jinsang;Lee, Seungjoo
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.6 no.1
    • /
    • pp.45-57
    • /
    • 2016
  • This paper proposes an adaptive channel estimation scheme for OFDM-based IEEE 802.11ad wireless local area network (WLAN). The standard supports two types of information of OFDM packets for estimating the communication channels, which are the channel estimation field (CEF) of preamble and pilot subcarriers. The CEF-based channel estimation provides better BER (bit error rate) performance at slow fading channel state, whereas the pilot-based channel estimation is good at fast fading channel state. Hence, a combined channel estimation method is introduced to improve the performance. The prediction of the channel state to select the proper channel estimation method is required. In this work, an adaptive channel estimation scheme is also proposed to improve the performance of channel estimation (CE). Basing on a channel quality indicator (CQI), the proper channel estimation method corresponding to the channel type is decided.

THE EFFECTS OF FABRICATION OF GOLD CYLINDER AND ABUTMENT ON THE FITNESS AND PRELOAD OF THE PROSTHESIS (지대주와 금속 실린더의 종류가 보철물의 적합도 및 preload에 미치는 영향)

  • Ha Jum-Im;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.451-465
    • /
    • 2003
  • Statement of problem : Recently various implant components such as premachined gold cylinder, plastic cylinder gold UCLA abutment and plastic abutment were developed and used clinically without clinical investigation. Purpose : The purpose of this study was to evaluate the effects of fabrication of gold cylinder on the fitness and preload of the standard abutment and also the effects of fabrication of UCLA gold abutment on the fitness and stress transfer around the implant fixture. Material and method : Three kinds of gold cylinders such as, as-received gold cylinder (Nobel Biocare, Sweden), gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were tested over the top of the standard abutment. At the same time, three types of abutments such as, gold UCLA abutment before and after casting, and plastic abutment after casting were tested. The cylinder and abutment was secured over the fixture with conventional pre-load values using an electronic torque controller (Nobel Biocare, Sweden). The fitness of the abutment on the fixture and gold cylinder over the standard abutment were measured using the microhardness tester (MXT 70, Matsuzawa, Japan). Preload and the strain values were recorded using the strain balance unit (SB-10, Measurement group, Raleigh, USA) and strain indicator (P-3500, Measurement group, Raleigh, USA) systems. Results and conclusion : 1. Significant differences were found in the fit between the gold cylinder and plastic cylinder. 2 There were significant differences between the preload of the gold cylinder and that of the plastic cylinder. 3. Significant differences were found in the fit between the gold UCLA abutment and plastic UCLA abutment. 4. There were no significant differences in the stress generated on the supporting structure of the fixture among different cylinder and abutment groups.

Cost-Effectiveness Analysis of Granisetron-Based versus Standard Antiemetic Regimens in Low-Emetogenic Chemotherapy: A Hospital-based Perspective from Malaysia

  • Keat, Chan Huan;Ghani, Norazila Abdul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7701-7706
    • /
    • 2013
  • Background: In a prospective cohort study of antiemetic therapy conducted in Malaysia, a total of 94 patients received low emetogenic chemotherapy (LEC) with or without granisetron injections as the primary prophylaxis for chemotherapy-induced nausea and vomiting (CINV). This study is a retrospective cost analysis of two antiemetic regimens from the payer perspective. Materials and Methods: This cost evaluation refers to 2011, the year in which the observation was conducted. Direct costs incurred by hospitals including the drug acquisition, materials and time spent for clinical activities from prescribing to dispensing of home medications were evaluated (MYR 1=$0.32 USD). As reported to be significantly different between two regimens (96.1% vs 81.0%; p=0.017), the complete response rate of acute emesis which was defined as a patient successfully treated without any emesis episode within 24 hours after LEC was used as the main indicator for effectiveness. Results: Antiemetic drug acquisition cost per patient was 40.7 times higher for the granisetron-based regimen than for the standard regimen (MYR 64.3 vs 1.58). When both the costs for materials and clinical activities were included, the total cost per patient was 8.68 times higher for the granisetron-based regimen (MYR 73.5 vs 8.47). Considering the complete response rates, the mean cost per successfully treated patient in granisetron group was 7.31 times higher (MYR 76.5 vs 10.5). The incremental cost-effectiveness ratio (ICER) with granisetron-based regimen, relative to the standard regimen, was MYR 430.7. It was found to be most sensitive to the change of antiemetic effects of granisetron-based regimen. Conclusions: While providing a better efficacy in acute emesis control, the low incidence of acute emesis and high ICER makes use of granisetron as primary prophylaxis in LEC controversial.

Degrees of Understanding Regarding Information Literacy in Korean University Students (우리나라 대학생들의 정보활용능력 인식도에 관한 연구)

  • Lee, Hyun-Sil;Choi, Sang-Ki
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.16 no.1
    • /
    • pp.91-112
    • /
    • 2005
  • This is a survey study to measure degrees of understanding regarding Information literacy in Korean university students based on ACRL standards. In the results of the survey there were no meaningful differences between individuals age, gender, major, and University. There were also no meaningful difference between the five ACRL standards. However, there were meaningful differences between the performance indicators in each standard. For example in the first standard, the performance indicator 'Determines the nature and extent of the information needed', had the highest score. had the lowest score. In the second ‘Effective Access of Information', had the highest score. In the third ‘Evaluate and Incorporate Information', had the highest score>and had the lowest score. In the fourth ‘Use of Information', , had the highest score. In the last ‘Information Ethics', there was no meaningful difference. This study also showed outcomes regarding the details in each standard.

  • PDF

A Design Study of Standard Indicators for Evaluating the Technical Performance of an NCS Core Vocational Competence System (직업기초능력 평가시스템의 기술성능 평가를 위한 표준지표 설계 연구)

  • Kim, Seung-Hee;Chang, Young-Hyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.111-117
    • /
    • 2017
  • The National Competency Standards (NCS) was designed to implement a competence-based society and solve the problem of inconsistency between the industrial field and education, training, and certification system. This study designed and developed the Korean NCS core vocational competence system, in accordance with the NCS, as an infrastructure to solve fundamental problems such as re-education and the social costs that are incurred in the workplace. Further, this study designed and developed standard indicators to evaluate the technical performance of the system for the global advancement of the Korean NCS core vocational competence system. The NCS core vocational competence system has been developed as an appropriate response type for multiple devices such as computers, tablet PCs, and cellular phones. For the global advancement of the Korean NCS core vocational competence system, this study designed and developed 10 performance evaluation indicators in accordance with 10 global standards, such as linkage-target operating system, interface protocol, packet format, encryption, class component, simultaneous access number, supervisor-to-testtaker response speed, server-to-admin response speed, auto-recovery speed for test answers, and real-time answer transmission speed.

Development of Biological Criteria for Water Quality Assessment using Benthic Diatoms (부착돌말류를 이용한 생물학적 수질평가지표 개발)

  • Noh, Seongyou;Byeon, Myeongseop;Kim, Miah;Lee, Jaekwan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.879-885
    • /
    • 2009
  • The present study was carried out to develop biological criteria for water quality assessment using benthic diatoms. Selecting of the indicator diatoms, three parameters were considered: broad distribution (180 taxa occurred over 3% at upper level), species abundance (158 taxa occurred over $1.5{\times}10^5cells/cm^2$), and sensitivity (184 taxa occurred more than once as 1st and 2nd dominant species). Overall, total 208 taxa were selected, including 38 varieties, 170 species, 34 genera, 9 families, 3 orders, and 1 phylum. The most dominant taxonomic group (family) was Naviculaceae (52%), followed by Diatomaceae (15%), Nitzschiaceae (12%) and Achnantaceae (11%). COD and TP were proposed as new water quality standards (draft) to improve the existing BOD standard and to manage and control efficiently non-biodegradable organic pollutants. With this regard, we used TP standard (draft) in developing biological water quality criteria for diatoms. TP standards (draft) proposed as Ia = 0.02 mg/L or less, Ib = 0.05 mg/L or less, II = 0.1 mg/L or less, III = 0.2 mg/L or less, IV = 0.4 mg/L or less, V = 0.6 mg/L or less and VI = above 0.6 mg/L. Biological assessment system (4 class system) was developed and proposed for diatom using modified Tropic Diatom Index (TDI). Biological assessment of TDI appear B grade (Good).

Measurement of lipid content of compost fermentation using near-infrared spectroscopy

  • Daisuke Masui;Suehara, Ken-ichiro;Yasuhisa Nakano;Takuo Yano
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of the compost during the compost fermentation of tofu (soybean0curd) refuse. The absorption of lipid observed at 5 wavelengths, 1208, 1712, 1772, 2312 and 2352 nm on the second derivative spectra. To formulated a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using Soxhlet extraction method. The value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712 nm were used in the calibration equation. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation was calculated using the calibration equation, and compared with the value obtained using the Soxhlet extraction method. Good agreement was observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. suitability of the lipid content as an indicator of the compost fermentation of tofu refuse was also studied. The decrease of the lipid content in the compost corresponded to the decrease of the total dry weight of the compost in the composter. The lipid content was a significant indicator of the compost fermentation. The NIRS method was applied to measure the time course of the lipid content in the compost fermentation and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.

The Development and Application of the Performance Indicator for Sewage System Service in Korea (하수도서비스 평가지표 개발 및 적용에 관한 연구)

  • Ahn, Young Mi;Kim, Duk-Jin;Yoon, Hyun Shik;Kim, Young Jo;Yoo, Man Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.453-465
    • /
    • 2007
  • With rapid expansion of the water market and growth of water companies, the recent trends in international water industry show that standardization of service activities concerning management of water and wastewater system (ISO/TC 224, to be issued in the second half year of 2007) is expected to have a large influence on the global water market including liberalization of water service market. In the Draft International Standard(DIS) of ISO/TC224, Performance Indicators(PIs) are suggested to estimate the service activities relating to water and wastewater treatment facilities. PIs have been developed in many countries including some international organization(World Bank, IWA and etc.) for service benchmarking. To evaluate public service level and establish plans to improve service level of wastewater utilities, we developed PIs for 120 items and applied them to 10 sewage utilities in the consideration of their scales, circumstances and conditions. In this study, we verified the applicability of the developed performance indicators(PIs). So, we concluded that PIs developed for the purpose of this study can be a useful tool applicable to objective evaluation of the service level of sewage utilities. Using the evaluation tool of PIs developed, it can also be used as a benchmarking tool in this industry as well as for enhancing the efficiency of operation and management of the sewage system. It will also contribute to the water resource management through determination of investment priorities based on the evaluation results and to raising international competitiveness of the domestic sewage utilities to meet the future opening of the water market.

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

A Proposal of Risk Management Framework for Design as a Secure Power Control System (안전한 전력 제어시스템 설계를 위한 위험관리 프레임워크 제안)

  • Park, Jun Yong;Shin, Sumin;Song, Kyoung-Young
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.425-433
    • /
    • 2016
  • In smart grid, enhancement of efficiency and interoperability of electric power system is achieved through the connection with outer network, and this induces that power grid system is threatened increasingly, becomes the main target of cyber terrorism, and is sincerely required to design the secure power system. Although SSDLC(Secure System Development Life Cycle) is used for risk management from the design phase, traditional development life cycle is somewhat limited for satisfaction of information security indicator of power control system. Despite that power control system should reflect control entities of information security considering its own characteristics, validation elements are insufficient to apply into real tasks based on existing compliance. To make design of diagnostic model and assessment process for power control system possible and to give a direction for information security and present related indicator, we propose the new risk management framework of power control system which is applied operational security controls and standard architecture presented by IEC 62351 TC 57 with enterprise risk management framework.