• Title/Summary/Keyword: Standalone

Search Result 219, Processing Time 0.023 seconds

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

Construction of MATLAB API for Fuzzy Expert System Determining Automobile Warranty Coverage (자동차 보증수리 기간 결정을 위한 퍼지 전문가 시스템용 MATLAB API의 구축)

  • Lee, Sang-Hyoun;Kim, Chul-Min;Kim, Byung-Ki
    • The KIPS Transactions:PartD
    • /
    • v.12D no.6 s.102
    • /
    • pp.869-874
    • /
    • 2005
  • In the recent years there has been an increase of service competition in the activity of product selling, especially in the extension of warranty coverage and qualify. The variables in connection with the service competition are not crisp, and required the expertise of the production line. It thus becomes all the more necessary to use subtler tools as decision supports. These problems are typical not only of product companies but also of financial organizations, credit institutions, insurance, which need predictions of credibility for firms or persons in which they have any kind of interest. A suitable approach for minimizing the risk is to use a knowledge-based system. Most often expert systems are not standalone programs, but are embedded into a larger application. The aim of this paper is to discuss an approach for developing an embedded fuzzy expert system with respect to the product selling policy, especially to present the decision system of automobile selling activity around the extension of warranty coverage and quality. We use the MATLAB tools which integrates computation, visualization, and programming in an easy-to-use environment where problems and solutions are expressed in familiar mathematical notation. Also, we present the API functions embedding into the existing application.

Design and Implementation of DEVSim++ and DiskSim Interface for Interoperation of System-level Simulation and Disk I/O-level Simulation (시스템수준 시뮬레이션과 디스크 I/O수준 시뮬레이션 연동을 위한 DEVSim++과 DiskSim 사이의 인터페이스 설계 및 구현)

  • Song, Hae Sang;Lee, Sun Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.4
    • /
    • pp.131-140
    • /
    • 2013
  • This paper deals with the design and implementation of an interface for interoperation between DiskSim, a well-known disk simulator, and a system-level simulator based on DEVSim++. Such inter-operational simulation aims at evaluation of an overall performance of storage systems which consist of multiple computer nodes with a variety of I/O level specifications. A well-known system-level simulation framework, DEVSim++ environment is based on the DEVS formalism, which provides a sound semantics of modular and hierarchical modeling methodology at the discrete event systems level such as multi-node computer systems. For maintainability we assume that there is no change of the source codes for two heterogeneous simulation engines. Thus, we adopt a notion of simulators interoperation in which there should be a means to synchronize simulation times as well as to exchange messages between simulators. As an interface for such interoperation DiskSimManager is designed and implemented. Various experiments, comparing the results of the standalone DiskSim simulation and the interoperation simulation using the proposed interface of DiskSimManager, proved that DiskSimManager works correctly as an interface for interoperation between DEVSim++ and DiskSim.

Performance Verification of Psudolite-based Augmentation System Using RF signal logger and broadcaster (RF 신호 수집/방송 장치를 활용한 의사위성 기반 광역보정시스템의 후처리 성능 검증)

  • Han, Deok-Hwa;Yun, Ho;Kim, Chong-Won;Kim, O-Jong;Kee, Chang-Don
    • Journal of Navigation and Port Research
    • /
    • v.38 no.4
    • /
    • pp.391-397
    • /
    • 2014
  • Wide Area Differential GNSS(WA-DGNSS) was developed in order to improve the accuracy and integrity performance of GNSS. In this paper, overall structure of Pseudolite-Based Augmentation System(PBAS) and experimental methods which enables the post-processing test with commercial receiver will be described. For generating augmenting message, GPS measurement collected from five NDGPS reference stations were processed by reference station S/W and master station S/W. The accuracy of augmenting message was tested by comparing SP3, IONEX data. In the test, RF signal of user was collected and correction data were generated. After that, RF signal was broadcasted with pseudolite signal. Test was conducted using three commercial receiver and the performance was compared with MSAS and standalone user. From the position output of each receiver, it was shown that improved position was obtained by applying augmenting message.

Determination of Precipitable Water Vapor from Combined GPS/GLONASS Measurements and its Accuracy Validation (GPS/GLONASS 통합관측자료를 이용한 가강수량 산출과 정확도 검증)

  • Sohn, Dong Hyo;Park, Kwan Dong;Kim, Yeon Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.4
    • /
    • pp.95-100
    • /
    • 2013
  • Several observation equipments are being used for determination of the water vapor content and precipitable water vapor (PWV) because the water vapor is highly variable temporally and spatially. In this study, we used GNSS systems such as GPS and GLONASS in standalone and combined modes to compute PWV and validated their accuracy with respect to the results of other water-vapor monitoring systems. The other systems used were radiosonde and microwave radiometer, and the comparisons were convenient because all three systems were collocated at the test site. The differences of PWW were in the range of 0.6-3.4 mm in the mean sense, and their standard deviations were 1.0-3.8 mm. The relatively large difference of GNSS compared with the other two systems were believed to be caused by the fact that the GNSS antenna used in this study was the kind for which the international standard of phase center variations (PCV) calibration is not available. We expect better accuracy of PWV determination and improved availability of it through integrated data processing of GPS/GLONASS when an appropriate antenna with PCV correction model is used.

Autothermal Reforming Reaction at Fuel Process Systems of 1Nm3/h (1 Nm3/h급 연료 변환시스템에서 메탄의 자열 개질반응)

  • Koo, Jeong-Boon;Sin, Jang-Sik;Yang, Jeong-Min;Lee, Jong-Dae
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.802-807
    • /
    • 2012
  • The autothermal reforming of methane to syngas has been carried out in a reactor charged with both a Ni (15 wt%)-Ru (1 wt%)/$Al_2O_3$-MgO metallic monolith catalyst and an electrically-heated convertor (EHC). The standalone type reactor has a start-up time of less than 2 min with the reactant gas of $700^{\circ}C$ fed to the autothermal reactor. The $O_2/CH_4$ and $H_2O/CH_4$ ratio governed the methane conversion and temperature profile of reactor. The reactor temperature increased as the reaction shifted from endothermic to exothermic reaction with decreasing $H_2O/CH_4$ ratio. Also the amount of $CO_2$ in the products increases with increasing $H_2O/CH_4$ ratio due to water gas shift reaction. The 97% of $CH_4$ conversion was obtained and the reactor temperature was maintained $600^{\circ}C$ at the condition of $GHSV=10,000\;h^{-1}$ and feed ratio ($H_2O/CH_4=0.6$ and $O_2/CH_4=0.5$). In this condition, the maximum flow rate of the syngas generated from the reactor charged with 170 cc of the metallic monolith catalyst is $0.94\;Nm^3/h$.

Development of Soil Erosion Analysis Systems Based on Cloud and HyGIS (클라우드 및 HyGIS기반 토양유실분석 시스템 개발)

  • Kim, Joo-Hun;Kim, Kyung-Tak;Lee, Jin-Won
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.63-76
    • /
    • 2011
  • This study purposes to develop a model to analyze soil loss in estimating prior disaster influence. The model of analyzing soil loss develops the soil loss analysis system on the basis of Internet by introducing cloud computing system, and also develops a standalone type in connection with HyGIS. The soil loss analysis system is developed to draw a distribution chart without requiring a S/W license as well as without preparing basic data such as DEM, soil map and land cover map. Besides, it can help users to draw a soil loss distribution chart by applying various factors like direct rain factors. The tools of Soil Loss Anaysis Model in connection with HyGiS are developed as add-on type of GMMap2009 in GEOMania, and also are developed to draw Soil Loss Hazard Map suggested by OECD. As a result of using both models, they are developed very conveniently to analyze soil loss. Hereafter, these models will be able to be improved continuously through researches to analyze sediment a watershed outlet and to calculate R value using data of many rain stations.

X-TOP: Design and Implementation of TopicMaps Platform for Ontology Construction on Legacy Systems (X-TOP: 레거시 시스템상에서 온톨로지 구축을 위한 토픽맵 플랫폼의 설계와 구현)

  • Park, Yeo-Sam;Chang, Ok-Bae;Han, Sung-Kook
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.2
    • /
    • pp.130-142
    • /
    • 2008
  • Different from other ontology languages, TopicMap is capable of integrating numerous amount of heterogenous information resources using the locational information without any information transformation. Although many conventional editors have been developed for topic maps, they are standalone-type only for writing XTM documents. As a result, these tools request too much time for handling large-scale data and provoke practical problems to integrate with legacy systems which are mostly based on relational database. In this paper, we model a large-scale topic map structure based on XTM 1.0 into RDB structure to minimize the processing time and build up the ontology in legacy systems. We implement a topic map platform called X-TOP that can enhance the efficiency of ontology construction and provide interoperability between XTM documents and database. Moreover, we can use conventional SQL tools and other application development tools for topic map construction in X-TOP. The X-TOP is implemented to have 3-tier architecture to support flexible user interfaces and diverse DBMS. This paper shows the usability of X-TOP by means of the comparison with conventional tools and the application to healthcare cancer ontology management.

Image Registration for PET/CT and CT Images with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합)

  • Lee, Hak-Jae;Kim, Yong-Kwon;Lee, Ki-Sung;Moon, Guk-Hyun;Joo, Sung-Kwan;Kim, Kyeong-Min;Cheon, Gi-Jeong;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2009
  • Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  • PDF

Evaluation of MT1XT20 Single Quasi-Monomorphic Mononucleotide Marker for Characterizing Microsatellite Instability in Persian Lynch Syndrome Patients

  • Farahani, Najmeh;Nikpour, Parvaneh;Emami, Mohammad Hassan;Hashemzadeh, Morteza;Zeinalian, Mehrdad;Shariatpanahi, Seyed Shervin;Salehi, Rasoul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4259-4265
    • /
    • 2016
  • Background: Colorectal malignancies with high microsatellite instability (MSI-H), either hereditary (Lynch syndrome) or sporadic, demonstrate better prognosis and altered response to 5FU chemotherapy. It is now recommended to perform MSI testing for all new cases of colorectal cancer regardless of being categorized as hereditary or sporadic. For MSI detection, immunohistochemistry or PCR-based protocols using a cohort of various sets of STR markers are recommended. Here we aimed to evaluate a simplified protocol using just a single STR marker, MT1XT20 mononucleotide repeat, for detection of MSI in Lynch syndrome patients. A Promega five-marker MSI testing panel and immunohistochemistry (IHC) were used as the gold standard in conjunction with MT1XT20. Materials and Methods: Colorectal patients with a positive history of familial cancers were selected by evaluating medical records. Based on Amsterdam II criteria for Lynch syndrome 20 families were short listed. DNA was extracted from formalin fixed paraffin embedded tumour and adjacent normal tissues resected from the index case in each family. Extracted DNA was subjected to MT1XT20 mononucleotide marker analysis and assessment with a commercially available five marker MSI testing kit (Promega, USA). IHC also was performed on tissue sections and the results were compared with PCR based data. Results: Eight (40%), seven (35%) and five (25%) cases were MSI positive using with the Promega kit, IHC and MT1XT20, respectively. Among the markers included in Promega kit, BAT26 marker showed instability in all 8 samples. NR24 and NR21 markers showed instability in 7 (87.5%), and BAT25 and MONO 27 in 6 (75%) and 5 (62.5%). Conclusions: Although MT1XT20 was earlier reported as a valid standalone marker for MSI testing in CRC patients, we could not verify this in our Iranian patients. Instead BAT26 among the markers included in Promega MSI testing kit showed instability in all 8 MSI-H CRC samples. Therefore, it seems BAT26 could act well as a single marker for MSI testing in Iranian CRC patients.