• 제목/요약/키워드: Stand-by power

검색결과 332건 처리시간 0.025초

비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발 (Development of 3kW Hybrid ESS with Function of Emergency Power Supply)

  • 양석현;김민재;최세완;조준석
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

유도전동기 구동을 위한 PV 시스템의 퍼지기반 MPPT 제어 (Fuzzy-Based MPPT Control of Photovoltaic System to Drive Induction Motor)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.24-30
    • /
    • 2009
  • 본 논문은 유도전동기 구동을 위한 태양광 발전시스템의 퍼지기반 MPPT 제어를 제시한다. 태양광 발전시스템의 최대 출력을 위하여 퍼지제어기를 이용한다. 퍼지제어기는 입력으로 최대 출력과 실제출력의 오차와 오차변화분을 사용하고 제어변수로 전압 변화분을 출력한다. 태양광 발전시스템은 퍼지기반 MPPT를 이용하여 유도전동기를 구동한다. 본 논문에서 제시한 퍼지기반 MPPT 제어는 종래의 PI 제어기와 비교를 통해 MPPT 추적성능 및 드라이브 구동성능 비교를 통해 타당성을 입증한다.

유도전동기 구동을 위한 태양광 발전의 Fuzzy-Based MPPT 제어 (Fuzzy-Based MPPT Control of Photovoltaic to Drive Induction Motor)

  • 최정식;고재섭;정병진;김도연;박기태;최정훈;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.198-200
    • /
    • 2007
  • This paper is proposed by fuzzy-based MPPT control of photovoltaic to drive induction motor. Design and prototype implement of a fuzzy logic(FL) controller for maximum power extraction from a stand-alon photovoltaic is proposed in this paper. Error and the change of error between maximum power and real power are used by input of fuzzy controller. Moreover, it output changing of voltage from control constant. The validity of this paper is proved by comparing maximum power point tracking and performance of motor drive through comparison fuzzy and PI of tradition method.

  • PDF

독립형 소형 태양광/풍력 복합발전시스템의 출력안정화를 위한 보조 전력보상장치개발에 관한 연구 (The Auxiliary Power Compensation Unit for Stand-Alone Photovoltaic/Wind Hybrid Generation System)

  • 박세준;윤정필;강병복;윤형상;차인수;임중열
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.47-54
    • /
    • 2004
  • Photovoltaic energy and wind energy are highly dependent on the season, time and extremely intermittent energy sources. Because of these reasons, in view of the reliability the photovoltaic and the wind power generation system have many problems(energy conversion, energy storage, load control etc.) comparing with conventional power plant. In order to solve these existing problems, hybrid generation system composed of photovoltaic(500W) and wind power system(400W) was suggested. But, hybrid generation system cannot always generate stable output due to the varying weather condition. So, the auxiliary power compensation unit that uses elastic energy of spiral spring was added to hybrid generation system for the present study. It was partly confirmed that hybrid generation system was generated a stable outputs by spiral spring was continuously provided to load.

마이크로터빈용 고속 영구자석 동기발전기 운전 특성 (Operating Characteristics of High Speed PM Synchronous Generator for Microturbine)

  • 안종보;정연호;강도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.141-143
    • /
    • 2004
  • Distributed generation(DG) using microturbine will be adopted widely because of its various usages and merits such as high heat efficiency, environmental-friendliness. Commercialized DG using microtubine that rotates up to $60,000\~100,000[rpm]$ converters mechanical power to electricity by permanent magnet synchronous machine. This paper presents comparative test and simulation results of PMSM as generator. Test was done by diode rectifier and inverter. Parameters used in the simulation are driven from FEM analysis. Under various speed and load conditions, V-I characteristics matches well and it suggests the possibility of high speed PMSM as generator. DG operating at stand alone and grid connection mode will be developed.

  • PDF

Analysis of Billet Rolling in a Continuous Mill using Idle Vertical Stands

  • Laila S. Bayoumi;Lee, Youngseog
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.762-769
    • /
    • 2004
  • An analytical approach is presented to investigate the deformation characteristics of billets in a continuous billet mill using power driven horizontal stands and idle vertical stands. The analysis is validated by comparison to the experimental results in a previously published work. The analytical results have shown that, apart from the problems of slip and buckling of billet, there are some shortcomings involved in this method. Compared to conventional rolling with all driven stands, the roll load for idle vertical stands and the rolling torque for horizontal stands are almost doubled. The billet is severely stressed within the roll-bite of idle vertical stands and the overall rolling power has increased by one third of that for conventional rolling. Theseshortcomings impair the feasibility of industrial application of idle vertical stand rolling method.

Advanced Control of a PWM Converter with a Variable-Speed Induction Generator

  • Ahmedt, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.97-108
    • /
    • 2007
  • This paper describes simple control structures for a vector controlled stand-alone induction generator (IG) for use under variable speeds. Different control principles, indirect vector control and deadbeat current control, are developed for a voltage source PWM converter and the three-phase variable speed squirrel-cage IG to regulate DC-link and generator voltages with a newly designed phase locked loop circuit. The required reactive power for the variable speed IG is supplied by means of a PWM converter and a capacitor bank to buildup the voltage of the IG without the need for a battery, to reduce the rating of the PWM converter while using only three sensors and to eliminate the harmonics generated by the PWM converter. These proposed schemes can be used efficiently for variable speed wind energy conversion systems. The measurements of the IG systems at various speeds and loads are given and show that these systems are capable of good AC and DC voltage regulation.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

유목민들을 위한 PV & Battery용 DC-DC 컨버터의 통합제어 알고리즘 (Combined Control Algorithm for a DC-DC Converter of PV & Battery for Mongolian Nomadic Life)

  • 투덴수런 오운자르갈;레덧탕;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제23권1호
    • /
    • pp.23-29
    • /
    • 2018
  • 독립형 태양광(PV) 시스템은 몽골 유목민 목축업자들에게 가장 중요한 에너지발전 시스템 중 하나이다. 기본적으로 독립형 PV 시스템은 두 개의 DC-DC 컨버터를 사용한다. 이 시스템은 비용이 많이 들고, 사이즈가 커지기 때문에 다른 장소로 이동 할 때 큰 어려움이 있다. 본 논문에서는 배터리의 SOC 제어 와 최대전력추종제어가(MPPT) 결합된 제어 알고리즘을 제안한다. 배터리는 3단계(Bulk, Absorption, Float Charge)로 충 방전된다. 본 논문에서는 Bulk단계에서 MPPT제어 기반으로 충전되는 제어 알고리즘을 제안한다. 제안된 제어 알고리즘을 다양한 날씨 조건에 대해서 적용하였으며, PSIM 소프트웨어를 이용한 시뮬레이션을 통하여 그 효용성을 검증하였다. 본 논문에서 제안한 알고리즘은 몽골 유목민들의 농촌 생활에 필수적인 독립형 태양광 발전 시스템을 설계하는데 유용하게 사용될 것이다.

독립형 태양광 발전소의 연 축전지 모니터링장치 개발 (A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems)

  • 문채주;김태곤;장영학;김의선;임정민
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.