• 제목/요약/키워드: Stand-alone

검색결과 698건 처리시간 0.029초

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

Treatment Modality Based Survival in Gastric Carcinoma Patients with Stand-Alone Peritoneal Metastasis: a Case-Control Study

  • Jeong, Oh;Jung, Mi Ran;Kang, Ji Hoon
    • Journal of Gastric Cancer
    • /
    • 제21권2호
    • /
    • pp.122-131
    • /
    • 2021
  • Purpose: To date, there are no promising treatments for gastric carcinoma with peritoneal metastasis. Some researchers have suggested a survival benefit of gastrectomy in select patients. This study investigated the survival of gastric carcinoma patients with stand-alone peritoneal metastasis according to the type of treatment modality. Materials and Methods: We reviewed the data of 132 patients with gastric carcinoma and stand-alone peritoneal metastasis. We performed gastrectomy when the primary tumor was deemed resectable and systemic chemotherapy was administered. We analyzed patient survival according to the type of treatment, and the prognostic value of gastrectomy was evaluated in univariate and multivariate models. Results: Among all patients, 70 underwent gastrectomy plus chemotherapy, 20 underwent gastrectomy alone, 36 underwent chemotherapy alone, and 6 received supportive care. The median patient survival was 13 months. Patients who underwent gastrectomy had significantly longer survival than those who did not undergo gastrectomy (14 vs. 8 months, P<0.001). Patients who received chemotherapy showed significantly longer survival than those who did not (13 vs. 7 months, P=0.032). Patients who underwent gastrectomy plus chemotherapy showed better survival than those who underwent other treatments. In multivariate analysis, gastrectomy was found to be an independent prognostic factor (hazard ratio, 0.52; 95% confidence interval, 0.33-0.82) in addition to chemotherapy. Conclusions: Our study showed that patients who underwent gastrectomy plus chemotherapy had the best survival. Although the survival benefit of gastrectomy remains uncertain, it is a favorable prognostic indicator in patients with stand-alone peritoneal metastasis.

비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구 (Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

소형 독립형 풍력발전기의 진동 모니터링 및 분석 (Vibration Monitoring and Analysis of a Small Stand Alone Wind Turbine Generator)

  • 김석현;유능수;남윤수;이정완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.64-67
    • /
    • 2005
  • A vibration monitoring system for a small size wind turbine (WIT) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW stand alone WIT generator is investigated. Acceleration data of the WIT tower under various operation condition is acquired in real time using LabVIEW and the data are remotely transferred from the test site to the laboratory in school by internet. Vibration response characteristics of the tower structure are diagnosed in the aspect of stability of W/T. Wind data and electrical power performance are also investigated with the stability problem.

  • PDF

독립형 태양광 풍력 복합발전 시스템에서 안정적인 전력공급을 위한 축전지 용량의 최적 산정에 관한 연구 (The Study on Optimize the Battery of Stand Alone PV/Wind Hybrid System for Supplying Stably Power)

  • 최병수;김재철
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.26-32
    • /
    • 2011
  • The object of this paper is to optimize the battery system for supplying stably power in separate house in which a PV-wind hybrid power generation system is applied. In a power system to be used in a stand alone, it is very important to build optimize the electrical storage system and to utilize it for supplying stably output voltage when there is a shortage of the power generation capacity or there is no sunshine, or when power is to be supplied with a load. This paper provides an optimized method to evaluate capacity of battery by analyzing advantages and disadvantages of the existing battery evaluating method being used in each company for supplying stably power in separate house utilizing the new renewable energy such as a light of the sun.

Stability Improvement of Battery Energy Storage System considering Synchronous Inductance Effect of Diesel Generator

  • Jo, Jongmin;An, Hyunsung;Chun, Kwan-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2254-2261
    • /
    • 2018
  • This paper analyzes stability of current control in respect of four cases of battery energy storage system (BESS) in a stand-alone microgrid. The stand-alone microgrid is composed of BESS, diesel generator and controllable loads, where all of them have a rated power of 50kW. The four cases are considered as following: 1) BESS with a stiff grid 2) BESS with the diesel generator 3) BESS with passive damping + diesel generator 4) BESS with active damping + diesel generator, and their stabilities are analyzed in the frequency domain and discrete time domain. The comparative analysis for four cases are verified through simulation and experiments through demonstration site of the stand-alone microgrid, where the DC link is connected to a 115kW battery bank composed of 48 lead-acid batteries (400AH/12V). Experimental results show a good agreement with the analysis.

태양광발전을 이용한 독립형 지하수 양수 시스템 개발 (Development of Stand-Alone Underground Water Pumping System using Photovoltaics System)

  • 이승훈;황정훈;조운식;김만일;이준기;박문희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

Accuracy Evaluation of IGS-RTS Corrections to Stand-Alone Positioning Based on GPS Code-Pseudorange Measurements

  • Kang, Min-Wook;Won, Jihye;Kim, Mi-So;Park, Kwan-Dong
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제5권2호
    • /
    • pp.59-66
    • /
    • 2016
  • The International GNSS Service (IGS) provides the IGS-Real Time Service (IGS-RTS) corrections that can be used in stand-alone positioning in real time. In this study, the positioning accuracy before and after the application of the corrections to broadcast ephemeris by applying the IGS-RTS corrections at code pseudo-range based stand-alone positioning was compared with positioning result using precise ephemeris. The analysis result on IGS-RTS corrections showed that orbit error and clock error were 0.05 m and 0.5 ns compared to precise ephemeris and accuracy improved by about 8.5% compared to the broadcast ephemeris-applied result when the IGS-RTS was applied to positioning. Furthermore, regionally dispersed five observatories were selected to analyze the effect of external environments on positioning accuracy and positioning errors according to location and time were compared as well as the number of visible satellites and position dilution of precision by observatory were analyzed to verify a correlation with positioning error.

인버터 시스템과 상용 전력 계통과의 병렬 운전에 관한 연구 (A Study on Parallel Operation Between Inverter System and Utility Line)

  • 천희영;박귀태;유지윤;안호균
    • 대한전기학회논문지
    • /
    • 제41권4호
    • /
    • pp.369-378
    • /
    • 1992
  • This paper proposes a utility parallel processing inverter system, which consists of a voltage source PWM inverter, isolation transformer and a reactor linking the inverter to utility line. This system realizes following functions : (1) voltage phase frequency and amplitude synchronization between inverter and utility line at stand-alone mode. (2) current phase synchronization between inverter and load at parallel mode. Therefore, despite sudden increase in load current over setting point at stand-alone mode, inverter system can be transferred into parallel mode immediately without transient current. Furthermore, high frequency(18KHz) PWM control and sinusoidal filtering improve the inverter output waveform by eliminating high order harmonic components as well as low order. As a switching device, IGBT is used for high frequency switching and large current capacity.

  • PDF

태양전지를 이용한 독립형 전원시스템 (A Stand-alone Source System using the Solar cell)

  • 이정준;조정민;성낙규;이승환;오봉환;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2565-2567
    • /
    • 1999
  • The output characteristics of solar cell vary with load and solar insolation. Therefore solar cell must always track maximum power point. If photovoltaic system is stand-alone. It is necessary to maintain for output of voltage source inverter. In this paper, stand-alone photovoltaic system consists of boost chopper and voltage source inverter. We make it to track maximum power point by revolution of solar cell array instead of detecting situation of sun in any conditions. And we prove that maximum power point tracking by revolution of solar cell array is better than fixed solar cell.

  • PDF