• Title/Summary/Keyword: Staircase

Search Result 170, Processing Time 0.024 seconds

Prediction of Reliability of Fatigue Limit of S34MnV Steel for Marine Diesel Engine Crank Throw Components (선박용 디젤 엔진 크랭크 스로 부품용 S34MnV강의 피로한도에 대한 신뢰도 예측)

  • Kim, Seon Jin;Kong, Yu Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.751-757
    • /
    • 2016
  • The aim of this study is to estimate the reliability of fatigue limit of the material used for crank throw components according to the staircase method. The material used for crank throw components is forged S34MnV grade steel, which is heat treated by normalizing and tempering. In this work, to predict the reliability of the design fatigue strength, axially loaded constant amplitude fatigue testing was conducted. The test specimens were loaded with an axial push/pull load with a mean stress of 0 MPa, which corresponds to a stress ratio of R=-1. The fatigue test results were evaluated by Dixon-Mood formulas. The values of mean fatigue strength and standard deviation predicted by the staircase method were 296.3 MPa and 10.6 MPa, respectively. Finally, the reliability of the fatigue limit in some selected probability of failure is predicted. The proposed method can be applied for the determination of fatigue strength for design optimization of the forged steel.

ROTATION NUMBER OF A CIRCLE HOMEOMORPHISM

  • Kim, Bong-Jo
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • We knew attractive qualities of a rotation number for an analytic diffeomorphism, for example, Arnold tongues and staircase. Numerical computer simulation let us know easily that the pattern of rotation number of a non analytic homeomorphism is similar to its of an analytic homeomorphism for some cases. Also we define new rotation function and investigate it's properties.

  • PDF

Design and Implementation of a New Multilevel DC-Link Three-phase Inverter

  • Masaoud, Ammar;Ping, Hew Wooi;Mekhilef, Saad;Taallah, Ayoub;Belkamel, Hamza
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.292-301
    • /
    • 2014
  • This paper presents a new configuration for a three-phase multilevel voltage source inverter. The main bridge is built from a classical three-phase two-level inverter and three bidirectional switches. A variable DC-link employing two unequal DC voltage supplies and four switches is connected to the main circuit in such a way that the proposed inverter produces four levels in the output voltage waveform. In order to obtain the desired switching gate signals, the fundamental frequency staircase modulation technique is successfully implemented. Furthermore, the proposed structure is extended and compared with other types of multilevel inverter topologies. The comparison shows that the proposed inverter requires a smaller number of power components. For a given number of voltage steps N, the proposed inverter requires N/2 DC voltage supplies and N+12 switches connected with N+7 gate driver circuits, while diode clamped or flying capacitor inverters require N-1 DC voltage supplies and 6(N-1) switches connected with 6(N-1) gate driver circuits. A prototype of the introduced configuration has been manufactured and the obtained simulation and experimental results ensure the feasibility of the proposed topology and the validity of the implemented modulation technique.

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.

Inundation Simulation of Underground Space using Critical Dry Depth Scheme (임계 마름 수심기법을 이용한 지하공간 침수 모의)

  • Rhee, Dong Sop;Kim, Hyung-Jun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.63-69
    • /
    • 2015
  • In this study, a 2D hydrodynamic model equipped with critical dry depth scheme was developed to reproduce the flow over staircase. The channel geometry of hydraulic experiment conducted by Ishigaki et al. was generated in the computational space, and the developed model was validated against flow properties such as discharge, velocity and momentum. In addition, the water surface profile and the velocity distribution evolved in flow over two layers staircases were analyzed. When the initial water depth at the upper floor was 0.3 m, the maximum velocity at lower floor was 4.2 m/s, and the maximum momentum was $1.2m^3/s^2$, and its conversion to force per unit width was 1.2 kN/m. This value was equivalent to the hydrostatic force with 50 cm water depth, and evacuation became difficult, as proposed by Ishigaki et al. For the flow over staircases connecting two layers, the maximum run-up height in flat part connecting two layers was approximately two times higher than the initial water depth in upper floor, and the rapid shock wave with sharp front and long tail was propagated.

Evaluation of staircase accidents using 3D virtual simulation based on behavioral characteristics of the elderly (가상공간 시뮬레이션을 활용한 고령자 행동특성 기반 계단 낙상사고 평가)

  • Yang, Hyun-Cheul;Na, Sun-Cheol;Kim, Dong-Hyun;Lee, Jae-Wook
    • Journal of KIBIM
    • /
    • v.7 no.4
    • /
    • pp.21-30
    • /
    • 2017
  • Due to the rapidly aging population, the death rate of elderly people by safety accidents has been increasing. In particular, precautions are needed for falls prevention because they either directly or indirectly cause death. In the case of elderly people, most of the fall accidents occur in dense residential areas, and particularly, the staircase poses a risk of falling. Therefore, a safety assessment should be performed from the design phase. However, in general, staircases are designed using existing stair data or only aims to satisfy the installation criteria. Laws and regulations only define minimum requirements for safety, so it is not possible to prevent fall accidents even if they satisfy the requirements. Therefore, this study proposes a simulation-based method for evaluating the safety of staircases. The behavioral characteristics of the elderly are implemented to an virtual user in a virtual space including staircases, and fall accidents are evaluated by the evaluation logic related to the behavioral characteristics. The result shows that the safety of staircases can be preevaluated and reflected on the design to reduce the possibility of fall accidents of the elderly.

Parabolic mirror test using Computer Generated Hologram (Computer Generated Hologram을 이용한 포물명경 형상측정)

  • 김성하;곽종훈;최옥신;송재봉;이윤우;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.80-84
    • /
    • 2000
  • Parabolic almninium mlITOr of m.5('||'&'||'cent; 50 nun) was fabncated by a diamond tummg machine. Computer generated hologram (CGH) for the test of parabolic mirror was encoded by binary phase hologram Approximation of curved fringe to line was made by staircase encoding. After fringe data 1ransformed mto a Post Scnpt file. magnified master CGH was printed by a laser printer, and then it reduced to the photographIc film. Parabolic mirror was tested by Twyman-Green interferometer with CGH at VIewing arm. Its experimental result was compared with those of surface profile and auto-collimatIon test, and then the errors were analyzed.

  • PDF

Deinterlacing Using Multi-Directional Edge Information (다각도의 에지 정보를 이용한 디인터레이싱)

  • Lee, Dong-Wook;Kang, Mun-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.92-96
    • /
    • 2010
  • Deinterlacing methods are usually divided into inter-field deinterlacing and intra-field deinterlacing. The most common method of intra-field deinterlacing is the linear method which uses line doubling or line averaging. There are also some edge-enhancement methods such as ELA(Edge Based Line Average) and modified ELA. However, the linear interpolation generates edge blurring or staircase artifacts. The methods using ELA or modified ELA show poor deinterlacing at various types of edges because of insufficient edge information in a certain direction. This paper presents an intra-field deinterlacing algorithm that considers the interpolation based on edges in 7 directions and an edge line in the horizontal direction. It demonstrates better picture quality by reducing the staircase phenomenon of object in the conventional methods.

A Novel Conformal FETD Method for Modeling Arbitrary Dielectric Surfaces (임의 유전체 경계면의 FDTD 모델링을 위한 새로운 적합법)

  • 이재용;명노훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.180-186
    • /
    • 1999
  • Conformal methods such as staircase approximation and effective medium theory have been used to model arbitrary dielectric surfaces in Cartesian FDTD(finite-difference time-domain) grids. However, the staircase approximation doesn't guarantee accurate results and the effective medium theory cannot be applied for frequency dispersive medium. In this paper, a simple conformal method is introduced for analyzing arbitrary dielectric surfaces. These arbitrarily shaped dielectric surfaces make nonuniformly filled FDTD cells. E(H)-field in a nonuniformly filled FDTD cell is calculated by considering the cell as the combination of two kinds of uniformly filled cells whose material boundaries are normal and parallel to the E(H)-field in the cell. TM scattering from a rotated 2-D dielectric and a ferrite square cylinder is analyzed to show the accuracy of the proposed method.

  • PDF

The Evaluation of the Village Community Center in Aspects of Universal Design Principles - Focused on 25 Village Community Centers in Hwasoon Province - (농촌 마을회관의 유니버설디자인 적용성 평가 - 전남 화순군 25개 마을회관을 중심으로 -)

  • Moon, In-Young;Kim, Mi-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.1
    • /
    • pp.162-171
    • /
    • 2014
  • This study aimed to evaluate how universal design principles are embodied in the village community center. It will provide preliminary data on constructing a physical space of village community center as small community space in agricultural districts. To achieving the purpose in this study, the research conducted inspection using checklist to 25 village community centers at Hwasoon, Jeonnam province. The conclusion of this study is as follows: Living room and kitchen/dining room by supportive design urgently need installation of Western Style furniture and solutions of stair gap by accessible design, and also the evaluation is unsuited on a fire-gas alarm system and prevention of electric shook system on safety-oriented design. Entrance evaluated in principle for insufficient on safety handle by supportive design and spare chair by adaptable design, and also it unsuited on the solutions of door sill by accessible design and non-skid by safety-oriented design. Bathroom is insufficient lever handle and safety grip by supportive design, sink isn't suitable by adaptable design. Outdoor space information legislation staircase ramp installation and horizontal installation of the staircase was not built.