• Title/Summary/Keyword: Stack performance

Search Result 619, Processing Time 0.113 seconds

Experimental Analyses of Cell Voltages for a Two-cell PEM Stack Under Various Operating Conditions

  • Park, Sang-Kyun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.881-890
    • /
    • 2011
  • Analyses of performance and behavior of the individual PEM fuel cells (PEMFC) under different operating conditions are of importance optimally to design and efficiently to operate the stack. The paper focuses on experimental analyses of a two-cell stack under different operating conditions, which performance and behavior are measured by the voltage of a cell as well as the stack. Experimental parameters include stoichiometric ratio, temperature of the air supplied under different working stack temperatures and loads. Results showed that the cell voltages are dominantly influenced by the temperature of the air supplied among others. In addition, an inherent difference between the first and the second cell voltage exists because of the tolerances of the cell components and the resulting different over-potentials at different equilibrium states. Furthermore, it is shown that the proton conductivity in the membranes conditioned by the humidity in the cathode channel highly affects the voltage differences of the two cells.

A Study on the Optimization of Fuel-Cell Stack Design (연료 전지 냉각판의 최적 설계)

  • 홍민성;김종민
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.92-96
    • /
    • 2003
  • Feul-Cell system consists of fuel reformer, stack and energy translator. Among these parts, stack is a core part which produces electricity directly. In order to set a stack module, fabrication of appropriate stack, design of water flow path in stack and control of coolant are needed. Especially, oater or air is used as a coolant to dissipate heat. The different temperature of each electric cell after cooling affects the performance of the stack. Therefore, it is necessary that the relationship between coolant hearing rate, width of stack, properties of stack, and the shape of water flow path must be understood. For the optimal design, the computational simulation by CFD-ACE has been conducted and the resulting database has been constructed.

Analytical Study on the Oscillating Flow Effect in a Anode Channel of Direct Methanol Fuel Cells (연료극 왕복유동이 직접 메탄올 연료전지에 미치는 영향에 대한 해석적 연구)

  • Hwang, Yong-Sheen;Lee, Dae-Young;Kim, Seo-Young;Choi, Hoon;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.27-30
    • /
    • 2007
  • This study considers the feasibility of the concentration control of the methanol solution by oscillating flow in the anode channel of passive type Direct Methanol Fuel Cells(DMFC). DMFC stack performance is largely influenced by the fuel concentration. If the fuel concentration is either lower than 0.5M or more than 2M, its performance deteriorates seriously because of the fuel starvation or the fuel crossover. In this respect the optimization of the fuel concentration is crucially important to maximize the DMFC stack performance. In this work, the effects of oscillating actuation in the fuel supply are studied to control the fuel concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the DMFC stack.

  • PDF

Optimization of Fuel-cell stack design using CFD-ACE (CFD-ACE를 이용한 연료 전지 냉각판의 최적 설계)

  • 홍민성;김종민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.14-18
    • /
    • 2003
  • Feul-cell system consists of fuel reformer, stack and energy translator. Among these parts, slack is a core part which produces electricity directly. In order to set a stack module, fabrication of appropriate stack, design of water flow path in stack, and control of coolant are needed. Especially, water or air is used as a coolant to dissipate heat. The different temperature of each electric cells after cooling and the high temperature of the stack affect the performance of the stack, Therefore, it is necessary that the relationship between coolant, healing rate, width of slack, properties of stack, and the shape of water flow path must be understood. For the optimal design, the computational simulation by CFD-ACE has been conducted and the resulting database has been constructed.

  • PDF

A Study of Deduction of evaluation Items for Design of SOFC stack safety performance evaluation system (SOFC 스택 안전성능 평가 시스템 제작을 위한 평가항목 도출에 관한 연구)

  • Park, Tae-Seong;Nam, Tae-Ho;Lee, Duk-Gwon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.81-87
    • /
    • 2017
  • SOFC(Solid Oxide Fuel Cell) is one of the high-temperature fuel cells, SOFC system and Stack has a high temperature operating Characteristics. These Characteristics cause a lot of trouble in the design of the system and selection materials, securing durability, and securing safety performance. Therefore, For Commercialization and Supply of SOFC, the development of safety performance assessment techniques and evaluation systems should go together. In this study, we analyzed the evaluation items of SOFC Safety performance standards and risk factors of the stack for design of stack safety performance evaluation system. Based on the analyzed data, the evaluation item was deducted for design of stack safety performance evaluation system. Through the results of this study, we expect to facilitate the supply of SOFC and contribute to a safe use environment.

Effects of the Methanol Concentration, Wind Velocity and Stack Temperature on the performance of Direct Methanol Fuel Cell (직접 메탄올 연료 전지의 성능에 대한 메탄올 농도, 풍속 및 스택 온도의 영향)

  • Kim, Yong-Ha;Kim, Seok-Il
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.2
    • /
    • pp.21-26
    • /
    • 2007
  • DMFC(Direct Methanol Fuel Cell) has been considered as an attractive option to produce electric power in many application. In this study, in order to estimate the effects of the methanol concentration, wind velocity and temperature on the performance of DMFC, a physical prototype of DMFC was designed and manufactured, and the stack voltage of DMFC was measured during the operation of DMFC. Expecially, the experimental results showed that a low stack temperature, a low wind velocity and an excess methanol concentration lead to the increase of the time to reach the maximum stack voltage.

  • PDF

Dead-end Mode Operation of a Large Scale PEM Fuel Cell Stack (대면적 고분자전해질 연료전지의 데드엔드 운전)

  • Jeong, Jeehoon;Shin, Hyunkhil;Han, In-Su;Seo, Hakyu;Kim, Minsung;Cho, Sungbaek;Hur, Taeuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.1-83.1
    • /
    • 2010
  • A Dead-end mode operation is one of the best way to maximize the gas usage rate. But, some components of fuel cell stack like gas diffusion layer(GDL) or membrane can be damaged in dead-end mode operation. In this study, a Large Scale Polymer electrolyte membrane fuel cell(PEMFC) for a dead-end operation has been developed. The stack is composed with 4 cells which has over 400cm2 of active area. Hydrogen is used as a fuel, and oxygen is used as a oxidant. The dead-end operation performance was evaluated by a long-term dead-end mode operation. The fuel cell stack is operated over 1,500 hours in dead-end mode operating fuel cell test station. And the performance change of the fuel cell stack was investigated.

  • PDF

Review of alternative gate stack technology research during the last decade

  • Lee, Byoung-Hun;Kirsch, Paul;Alshareef, Husam;Majhi, Prashant;Choi, Rino;Song, Seung-Chul;Tseng, Hsing Huang;Jammy, Raj
    • Ceramist
    • /
    • v.9 no.4
    • /
    • pp.58-71
    • /
    • 2006
  • Scaling of the gate stack has been one of the major contributors to the performance enhancement of CMOSFET devices in past technology generations. The scalability of gate stack has diminished in recent years and alternative gate stack technology such as metal electrode and high-k dielectrics has been intensively studied during the last decade. Tody the performance of high-k dielectrics almost matches that of conventional $SiO_2-based$ gate dielectrics. However, many technical challenges remain to be resolved before alternative gate stacks can be introduced into mainstream technology. This paper reviews the research in alternative gate stack technologies to provide insights for future research.

  • PDF

Operation Characteristics of 100W Class Molten Carbonate Fuel Cell Stack (100W 급 용융탄산염 연료전지 스택운전특성)

  • Lim, Hee-Chun;Lee, Chang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.94-96
    • /
    • 1994
  • To develop the 2kw class MCFC stack, preliminarly 3 cell and 10 cell stack having a $100cm^2$ effective electrode area were fabricated and tested. These stacks showed 30 W and 100 W of output respectively and average cell voltage of 0.734V at $150mA/cm^2$. The stack performance decreased with the increase of fuel utilization rate. In durability test of 10 cell stack, the performance was sharply decreased at the rate of 180mV/1000Hr during 720hours operation time.

  • PDF

TA Study on the Performance and the Efficiency in Polymer Electrolyte embrane Fuel Cell (고분자전해질형 연료전지의 성능해석 및 효율에 관한 연구)

  • Kim Hong-Gun;Kim Yoo-Shin;Yang Sung-Mo;Nah Seok-Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.75-80
    • /
    • 2005
  • An experimental study is carried out to investigate the performance and the efficiency humidifying Membrane Electrolyte Assembly and having the double-tied catalyst layers in a fuel cell system which is taken into account the physical and thermal concept. Subsequently, an electric output produced by PEMFC(Polymer Electrolyte Membrane Fuel Cell) is measured to assess the performance of a stack, and the efficiency is also evaluated according to the different situation in which unit cell is placed with and without the humidification of the MEA. It is found that the measured values of stack voltage and current are influenced by the stack temperature, humidification, and the double-tied catalyst layers which give more enhanced values to be applied to electric units.