• Title/Summary/Keyword: Stability Limits

Search Result 354, Processing Time 0.025 seconds

Comparative Study of Two Congestion Management Methods for the Restructured Power Systems

  • Manikandan, B.V.;Raja, S. Charles;Venkatesh, P.;Mandala, Manasarani
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.302-310
    • /
    • 2011
  • Congestion management is one of the most challenging tasks of a system operator to ensure the operation of transmission system within operating limits. In this paper, cluster/zone method and relative electrical distance (RED) method for congestion management are compared based on the considered parameters. In the cluster/zone method, rescheduling of generation is based on user impact on congestion through the use of transmission congestion distribution factors. In the RED method, the desired proportions of generations for the desired overload relieving are obtained. Even after generation rescheduling, if congestion exists, load curtailment option is also introduced. Rescheduling cost, system cost, losses, and voltage stability parameter are also calculated and compared for the above two methods of congestion management. The results are illustrated on sample 6-bus, IEEE 30-bus, and Indian utility 69-bus systems.

On the Characteristics of Extinction and Re-ignition in a Crossed Twin Jet Counterflow (Crossed Twin Jet Counterflow에서의 소염과 재점화 특성)

  • Lee, B.K.;Yang, S.Y.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.25-31
    • /
    • 2002
  • For the better understanding of the stability of turbulent combustion, more researches on extinction and re-ignition are needed. Flame interactions in non-premixed flame have also not been greatly researched. We made a hybrid twin jet flame, the combinations of diffusion flame and partially-premixed diffusion flame, in a twin jet counterflow configuration. The extinction limits of a crossed twin jet counterflow have been extended in comparison with those of a one-dimensional counterflow because of flame interactions through heat transfer and joint ownership of various radicals. Besides, we have obtain ignition $Damk\"{o}hler$ number by experimental method without external ignition source using the extinction characteristic in a crossed twin jet counterflow flame. From results, we can identify the hysteresis between extinction and ignition $Damk\"{o}hler$ number in S-curve.

  • PDF

The Z-CUSUM Control Chart for the Process with Recurring Cycles or Frequent Small Shifts (순환 주기나 빈번한 작은 이동이 발생하는 공정관리를 위한 Z-CUSUM 관리도)

  • Kang Hae Woon;Kang Chang Wook;Paik Jae Won
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2004.04a
    • /
    • pp.57-63
    • /
    • 2004
  • CUSUM control charts are widely used to monitor processes with small shifts. CUSUM control charts, however, are less effective in detecting for recurring cycles or frequent small shifts in the process. With Shewhart control charts, we have applied the variety of run rules to check the stability of process in addition to the situations that some points fall outside the control limits. In this paper, we propose the Z-CUSUM control chart for monitoring the process with recurring cycles or frequent small shifts by use of the zone concept as like the Shewhart control charts.

  • PDF

A Study on the Strength of Geotextile and the Influence of Settlement in a Waste Landfill (폐기물 매립지 인공합성 차수재 강도와 침하영향에 관한 연구)

  • 장연수;임학수;권강오
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.241-245
    • /
    • 2000
  • In this paper, the results of the direct shear interface friction test is introduced to understand interface friction between geosynthetic materials that are required for analyzing slope stability of the liner system of waste landfills. Tensile stresses that occur in a liner system due to differential settlement with waste load are estimated using FLAC. It was shown that HDPE/geocomposite inteface friction angle is 11.9$^{\circ}$, HDPE/wastes is 12.0$^{\circ}$ and geotextile/wastes is 28.0$^{\circ}$. Tensile stress due to settlement in a foundation of landfill is well within the limits of tensile strength regulated by waste treatment law.

  • PDF

Effect on Body Balance due to mouth guard (마우스 가드가 신체 균형에 미치는 영향)

  • Won, Hyeon-Jin;Kim, Chi-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose: This study, it was observed on the effect of material and thickness of the mouth guard on postural balance in order to assess the influence of the use of a mouth guard. Methods: The mouth guards of 10 adults selected as the experiment subject was sorted into each of hard and soft material, and these were made as thickness of 2.0 mm, 2.5 mm, 3.0 mm, 3.5 mm by each of the material. Results: The results of this study are expected to wear the mouthguard hard to influence positive influence on the improvement of the muscle strength, static balance. Conclusion: Suggest the need for additional research on dynamic balance.

Application a Loop Compensation type 2-DOF PID Controller tuned by Neural Network to Gas Turbine Control Loop (가스터빈 제어 루프에 대한 신경망 튜닝 루프 보상형 2-자유도 PID 제어기의 응용)

  • Kim, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.781-786
    • /
    • 1998
  • Since a gas turbine is still a significant contributor to peak time, it is very important to tune the gains of P. I. D to get a maximum power and stability within permissible limits. In the gas turbine, the main control loop must adjust the fuel flow to ensure the correct output power and frequency. but it is not easy, because the control loop is composed of many subsystems. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply a loop compensation type 2-DOF PID controller tuning by neural-network to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

Robust Fuzzy Load-Frequency Control of Nonlinear Power Systems Using Intelligent Digital Redesign Technique (지능형 디지털 재설계 기법을 이용한 비선형 전력 계통의 강인 퍼지 부하 주파수 제어)

  • 이남수;이연우;전상원;주영훈
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.05a
    • /
    • pp.142-145
    • /
    • 2000
  • A new robust load-frequency control (LFC) methodology is proposed for nonlinear power systems with the valve position limits of the governor in the presence of parametric uncertainties. The Takagi-Sugeno (TS) fuzzy model is adopted for fuzzy modeling of the nonlinear power system. A sufficient condition of the robust stability is presented in the sense of Lyapunov for the TS fuzzy model with parametric uncertainties. The intelligent digital redesign technique for the uncertain nonlinear power system is also studied. The effectiveness of the proposed robust fuzzy LFC controller design method is demonstrated through a numerical simulation.

  • PDF

$H_\infty$ Optimal tuning of Power System Stabilizer using Genetic Algorithm (유전알고리즘을 이용한 전력계통 안정화 장치의 강인한 $H_\infty$최적 튜닝)

  • Jeong, Hyeong-Hwan;Lee, Jun-Tak;Lee, Jeong-Pil;Han, Gil-Man
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.3
    • /
    • pp.85-94
    • /
    • 2000
  • In this paper, a robust H$\infty$ optimal tuning problem of a structure-specified PSS is investigated for power systems with parameter variation and disturbance uncertainties. Genetic algorithm is employed for optimization method of PSS parameters. The objective function of the optimization problem is the H$\infty$-norm of a closed loop system. The constraint of the optimization problem are based on the stability of the controller, limits on the values of the parameters and the desired damping of the dominant oscillation mode. It is shown that the proposed H$\infty$ PSS tuned using genetic algorithm is more robust than conventional PSS.

  • PDF

HYPERSTABILITY OF A SUM FORM FUNCTIONAL EQUATION RELATED DISTANCE MEASURES

  • Lee, Young Whan
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.33 no.1
    • /
    • pp.147-156
    • /
    • 2020
  • The functional equation related to a distance measure f(pr, qs) + f(ps, qr) = M(r, s)f(p, q) + M(p, q)f(r, s) can be generalized a sum form functional equation as follows $${\frac{1}{n}}{\sum\limits_{i=0}^{n-1}}f(P{\cdot}{\sigma}_i(Q))=M(Q)f(P)+M(P)f(Q)$$ where f, g is information measures, P and Q are the set of n-array discrete measure, and σi is a permutation for each i = 0, 1, ⋯, n-1. In this paper, we obtain the hyperstability of the above type functional equation.

Facilitated ion transport through cellulose triacetate-based polymer inclusion membranes: A promising method for treatment of nuclear wastewater

  • Samuel P.Kusumocahyo;Toshiyuki Kanamori;Kim, io-Sumaru;Toshio Shinbo;Hideto Matsuyama;Masaaki Teramoto
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.43-46
    • /
    • 2004
  • The large quantity of liquid wastes from nuclear industries such as nuclear power plants would become a serious storage problem in view point of the environmental safety. The liquid wastes should be concentrated to a smallest possible volume before the storage. The use of supported liquid membranes (SLMs) for this purpose is very attractive [1,2], however loss of solvent and carrier in the surrounding solutions limits the stability of SLMs and hinders their commercial application in the industries.(omitted)

  • PDF