• 제목/요약/키워드: Stability Limit

검색결과 1,064건 처리시간 0.026초

상호작용하는 메탄-수소 예혼합 대향류화염에 관한 연구 (A Study on Interacting $CH_4$-Air and $H_2/N_2$-Air Premixed Counterflow Flames)

  • 문창우;박정;권오붕;배대석;김정수
    • 한국연소학회지
    • /
    • 제15권1호
    • /
    • pp.38-42
    • /
    • 2010
  • Using a counterflow burner, downstream interactions between $CH_4$-air and $H_2/N_2$-Air premixed flames with various equivalence ratios has been experimentally investigated. Flame stability maps on triple and twin flames are provided in terms of global strain rate and equivalence ratio. Lean and rich flammable limits are examined for methane/air and hydrogen/nitrogen/air mixtures over the entire range of mixture concentrations in the interacting flames. Results show that these flammable limits can be significantly modified in the presence of interaction such that mixture conditions beyond the flammability limit can be still burn if it is supported by stronger flame. The experiment also discusses various oscillatory instabilities in a stability map.

산업용 전력계통의 안정도 유지를 위한 과전류계전기의 시간지연 한계 (Time Delay Limit of Over Current Relay for Maintaining Stability in Industrial Power Systems)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.190-192
    • /
    • 2002
  • The industrial power distribution system is a radial system and therefore usually protected with time delayed over current relays (OCR's). Proper time dial settings are provided at the OCR's. Meanwhile, the systems, where synchronous generator, or synchronous motors, or large induction motors are operating, can not be protected with only OCR's with time grading. This paper presents a technical limit and a suitable range of time delay in applying OCR's to clearing faults in the industrial power systems for maintaining stability. Dynamic simulations are made to show them employing a real power systems of a large petro-chemical complex.

  • PDF

메탄 과농-희박 예혼합화염의 안정화 메커니즘 (Stabilizing Mechanism for Methane Rich-Lean Flame)

  • 이원남;서동규
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.19-24
    • /
    • 2002
  • Recent studies of a triple flame suggested that the presence of triple point (triple line in this planar configuration) could explain the mechanisms of stable fuel-lean premixed flames with equivalence ratio lower than the flammability limit. In the present study, for better understanding of the stability mechanisms of fuel rich-lean premixed flames, the fuel-rich flames were replaced with hot coils that will provide heat flux into the fuel-lean flames. It is found that the fuel-lean premixed flames could be stabilized without any triple point (triple line): however, the equivalence ratio limit for stable fuel-lean flame in this case is higher than that of the present work with the presence of fuel-rich flames. These results demonstrate that heat flux coming from fuel-rich flames should be considered in order to properly understand the roll of a triple flame for stable fuel rich-lean flames.

  • PDF

Development of a Chloroform Reference Material for the Proficiency Testing of Hazardous Compounds in Commercial Consumer Chemical Products Under the Consumer Chemical Products and Biocide Safety Management Act (K-BPR)

  • Lee, Sang Tak;Lee, Jae-ung;Kim, Joo-Hyon;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제10권4호
    • /
    • pp.112-116
    • /
    • 2019
  • In this study, a chloroform consumer chemical product (CCP) reference material (RM) is successfully developed, with potential to be used in the proficiency testing of hazardous compounds in CCPs for analysis and testing agencies. Validation experiments are rigorously conducted to evaluate whether the RM meets the requirements set by the ISO 13528 and ISO Guide 35, using a reliable GC/MS method for the analysis of chloroform. The obtained calibration plot linearity, limit of detection (LOD), and limit of quantitation (LOQ) are excellent. The developed RM meets the homogeneity and stability requirements; the between-unit (sbb) and within-unit (swb) standard deviations are less than 2.5%, and the stability is found to be guaranteed for 50 days.

Reactive Reserve based Contingency Constrained Optimal Power Flow to Enhance Interface Flow Limits in Terms of Voltage Stability

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • 제11권X00호
    • /
    • pp.27-32
    • /
    • 2001
  • This paper presents a concept of reactive reserve based contingency constrained optimal power flow (RCCOPF). RCCOPF for enhancement of interface flow limit is composed of two modules, which are the modified continuation power flow (MCPF) and reactive optimal power flow (ROPF). In RCCOPF, two modules are repeatedly performed to increase interface flow margins of selected contingent states until satisfying the required enhancement of interface flow limit. In numerical simulation, a simple example with New England 39-bus test system is shown.

저선회 연소기의 선회각도에 따른 영향 (Effect of Swirl Angles in Low-Swirl Combustor)

  • 정황희;최인찬;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.123-125
    • /
    • 2015
  • A study has been conducted to investigate the effect of swirl angle in low swirl combustor. In this study, the employed swirl angles were $28^{\circ}$, $32^{\circ}$ and $37^{\circ}$. Direct flame photos show that the width of the flame is expanded and the length of the flame is shortened when swirl angle is increased. Also, as the swirl angle was increased, the flame stability region could be widened due to the expansion of lower flammable limit. Between 3 and 7kW, CO emissions was below 10 ppm and NOx emissions was also below 27 ppm at $O_2$ 15% basis over the lean burning range of 0.6 < ${\Phi}$ < 0.9. From this investigation of stability expansion effect and emission performance, it was identified that the swirl angle $37^{\circ}$ is most suitable swirling condition in the low swirl model combustor.

  • PDF

ZAERO를 이용한 시간영역에서의 접는 날개 비선형 공탄성 해석 (Nonlinear Aeroelastic Analysis in Time Domain for Folded Fins using ZAERO)

  • 이동민;김정영
    • 한국군사과학기술학회지
    • /
    • 제11권4호
    • /
    • pp.159-165
    • /
    • 2008
  • The purpose of this paper is to study the impact of concentrated nonlinearities, freeplays, on the aeroelastic behaviors of single- and double-folded control fins. The nonlinearities may cause limit cycle oscillation(LCO) below the linear flutter boundary. The effects of nonlinear hinges on LCO characteristics of the fins are examined as flight condition changes. Nonlinear time-domain flutter analyses are performed, using ZAERO. The results show that the aeroelastic stability boundaries of double-folded fin(DF) are higher than those of the single-folded fin(SF) and the lower hinge freeplay impact more critically on the stability than the upper hinge freeplay of the DF.

컨테이너 화차의 주행안정성 평가에 관한 실험적 연구 (The Experimental Study on the Estimation of Running Stability for Container Carrier Car)

  • 함영삼;홍재성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2004
  • A domestic's freight stock is about 14,000 cars. Most of them is consisted of casting bogie type. Casting bogie type has some problems such as maintenance, part abrasion, running safety etc. Now a day casting bogie type have replaced with welded type bogie for high speed. The maximum speed of the container freight car is 70km/h limit at empty weight condition in case of casting type bogie frame. So there are some difficulty in commercial service for high speed coaches. Then we should re-decide whether the casting bogie type has speed up 90km/h limit at empty weight through out the vibration characteristic.

  • PDF

콘크리트궤도 침하복원을 위한 궤도/노반 인터페이스부 그라우팅이 주행안정성에 미치는 영향 (Effect of Settlement Restoration Grouting between concrete track/Roadbed on the train service stability)

  • 이일화;이성진;이태균;강태호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.796-804
    • /
    • 2008
  • Various design factors should be considered in order to apply the concrete slab track system on the soil/rock roadbed. One of the important factors is the settlement of roadbed. This settlement of concrete track should be supervised under the allowable settlement limit. If the settlement of roadbed under the concrete track exceed the allowable limit, the train serviceability will considerably come down and furthermore the fatal disaster may happen. Therefore, in this paper we introduced a digitalized grouting method as a settlement restoration method that can be suitably adopted to the concrete slab track. And we also evaluated the train service stability through the analysis of the track behavior according to the difference of the stiffness between the grouted part and the original roadbed.

  • PDF

현장계측에 의한 쏘일네일링 보강벽체의 변형특성에 관한 고찰 (A Consideration on Deformation Characteristics of Soil Nailed Retaining-Walls on Field Measurements)

  • 윤배식;이종문;강인규;권영호;김홍택
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.534-537
    • /
    • 2007
  • The soil nailing was generally using method in practical business, in application of the soil nailing, the analysis was primarily used to Beam-Colum Method, Finite Element Method and Limit Equilibrium Method. Beam-Colum Method and Finite Element Method were able to examine transformation but widely using Limit Equilibrium Method wasn't able to examine transformation and displacement Therefore, this study was focused on presenting stability in comparison with former study-results about horizontal displacement of the soil nailing retaining-walls satisfing a criterion safety factor of Limit Equilibrium. There were performing comparison field measurements and former study-results in first step.

  • PDF