• 제목/요약/키워드: Square section

검색결과 542건 처리시간 0.027초

Ultimate moment capacity of foamed and lightweight aggregate concrete-filled steel tubes

  • Assi, Issam M.;Qudeimat, Eyad M.;Hunaiti, Yasser M.
    • Steel and Composite Structures
    • /
    • 제3권3호
    • /
    • pp.199-212
    • /
    • 2003
  • An experimental investigation of lightweight aggregate and foamed concrete contribution to the ultimate strength capacity of square and rectangular steel tube sections is presented in this study. Thirty-four simply supported beam specimens, 1000-mm long, filled with lightweight aggregate and foamed concretes were tested in pure flexural bending to calculate the ultimate moment capacity. Normal concrete-filled steel tubular and bare steel sections of identical dimensions were also tested and compared to the filled steel sections. Theoretical values of ultimate moment capacity of the beam specimens were also calculated in this study for comparison purposes. The test results showed that lightweight aggregate and foamed concrete significantly enhance the load carrying capacity of steel tubular sections. Furthermore, it can be concluded from this study that lightweight aggregate and foamed concretes can be used in composite construction to increase the flexural capacity of the steel tubular sections.

4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가 (Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy)

  • 유하늬;이주윤;송규동
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

EVALUATION OF FAST NEUTRON FLUENCE FOR KORI UNIT 3 PRESSURE VESSEL

  • Yoo, Choon-Sung;Kim, Byoung-Chul;Chang, Kee-Ok;Lee, Sam-Lai;Park, Jong-Ho
    • Nuclear Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.665-674
    • /
    • 2006
  • Three-dimensional neutron flux and fluence of Kori Unit 3 were evaluated using the synthesis technique described in Regulatory Guide 1.190 for all reactor geometry. For this purpose DORT neutron transport calculations from Cycle 1 to Cycle 15 were performed using BUGLE-96 cross-section library. The calculated flux and fluence were validated by comparing the calculated reaction rates to the measurement data from the dosimetry sensor set of the $5^{th}$ surveillance capsule withdrawn at the end of cycle 15 of Kori Unit 3. And then the best estimation of the neutron exposures for the reactor vessel beltline region was performed using the least square evaluation. These results can be used in the assessment of the state of embrittlement of Kori Unit 3 pressure vessel.

On efficient estimation of population mean under non-response

  • Bhushan, Shashi;Pandey, Abhay Pratap
    • Communications for Statistical Applications and Methods
    • /
    • 제26권1호
    • /
    • pp.11-25
    • /
    • 2019
  • The present paper utilizes auxiliary information to neutralize the effect of non-response for estimating the population mean. Improved ratio type estimators for population mean have been proposed and their properties are studied. These estimators are suggested for both single phase sampling and two phase sampling in presence of non-response. Empirical studies are conducted to validate the theoretical results and demonstrate the performance of the proposed estimators. The proposed estimators are shown to perform better than those used by Cochran (Sampling Techniques (3rd ed), John Wiley & Sons, 1977), Khare and Srivastava (In Proceedings-National Academy Science, India, Section A, 65, 195-203, 1995), Rao (Randomization Approach in Incomplete Data in Sample Surveys, Academic Press, 1983; Survey Methodology 12, 217-230, 1986), and Singh and Kumar (Australian & New Zealand Journal of Statistics, 50, 395-408, 2008; Statistical Papers, 51, 559-582, 2010) under the derived optimality condition. Suitable recommendations are put forward for survey practitioners.

Shielding effects on a tall building from a row of low and medium rise buildings

  • Zu, G.B.;Lam, K.M.
    • Wind and Structures
    • /
    • 제27권6호
    • /
    • pp.439-449
    • /
    • 2018
  • Wind loading of a tall building built amidst a group of buildings in urban environment is always greatly affected by shielding effects. Wind tunnel tests were carried out to assess the shielding provided by a row of low-rise or medium-rise buildings upstream a square-section tall building of height-to-breadth ratio 6. Mean and dynamic wind loads on the tall building were measured at different wind incidence angles and presented as interference factors (IFs). It is found that presence of a row of upstream buildings provides significant shielding to the tall building. At normal wind incidence, the mean along-wind loads and all components of fluctuating wind loads on the tall building are always reduced by shielding. Vortex shedding seems to still occur on the upper exposed part of the tall building but the vortex excitation levels are largely reduced. The degree of shielding is found to depend on a number of arrangement parameters of the row of upstream buildings. Empirical equations are proposed to quantify the shielding effect based on the wind tunnel data.

Study of the effect of varying shapes of holes in energy absorption characteristics on aluminium circular windowed tubes under quasi-static loading

  • Baaskaran, N;Ponappa, K;Shankar, S
    • Structural Engineering and Mechanics
    • /
    • 제70권2호
    • /
    • pp.153-168
    • /
    • 2019
  • In this paper, energy absorption characteristics of circular windowed tubes with different section shapes (circular, ellipse, square, hexagon, polygon and pentagon) are investigated numerically and experimentally. The tube possesses the same material, thickness, height, volume and average cross sectional area which are subjected under axial and oblique quasi-static loading conditions. Numerical model was constructed with FE code ABAQUS/Explicit, the obtained outcome of simulation is in good matching with the experimental data. The energy absorbed, specific energy absorption, crash force efficiency, peak and mean loads along with the collapse modes with their initiation point of simple and windowed tubes were evaluated. The technique for order of preference by similarity ideal solution (TOPSIS) approach was employed for assessing their overall crushing performances. The obtained results confirm that efficacy of crash force indicators have improved by introducing windows and tubes with pentagonal and circular windows achieves the maximum ranking about 0.528 and 0.517, it clearly reveals the above are best window shapes.

지관이 회전된 냉간성형 각형강관 T형 접합부의 최대내력(II)-주관 웨브 파괴모드- (Ultimate Strength of branch-rotated T-joints in Cold-formed Square Hollow Sections-Chord web failure mode-)

  • 배규웅;박금성;강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제15권1호
    • /
    • pp.69-76
    • /
    • 2003
  • 본 논문에서 새로운 냉간성형 각형강관 T형 접합부의 최대내력과 변형제한치에 대한 연구이다. 새로운 접합부는 지관을 트러스 평면에 대하여 $45^{\circ}$회전시켜서 주관에 용접하는 형상이고, 지관 $45^{\circ}$회전형 T형 접합부 실험결과 중에서 주관 웨브 파괴가 지배하는 접합부만을 대상으로 설정하였다. $16.7{\leq}2{\gamma}(B/T){\leq}33.3$이고 $0.63{\leq}{\beta}(b_1/B){\leq}0.7$ 범위의 지관 $45^{\circ}$회전형 T형 접합부에 대하여, 최대내력을 정의를 위한 변형제한치는 주관폭의 3% 변형량(3%B) 으로 제안하였다. $0.63{\leq}{\beta}{\leq}0.7$ 범위의 기본형에 대한 기존의 항복선모델을 검토하고, 지관 $45^{\circ}$회전형에 대한 내력식을 제안하였다. 제안내력식은 기둥좌굴이론에 근거하고 있고, 냉간성형시 발생한 곡률부분을 고려하였다. 최종적으로 최적화된 주관단면 선택을 위한, 항복응력도와 $2{\gamma}$의 최적조건을 제안하였다.

원격판독 의료기관에서 시행한 원격판독의 동료평가: 세부전공분야와 촬영장비에 따른 판독 불일치 정도와 불일치 판독의 임상적 의의 비교 (Peer Review of Teleradiology at a Teleradiology Clinic: Comparison of Unacceptable Diagnosis and Clinically Significant Discrepancy between Radiology Sections and Imaging Modalities)

  • 서형석;박재성;오유환;성동욱;이아름
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1545-1555
    • /
    • 2021
  • 목적 동료평가를 시행하여 원격판독 불일치의 정도와 불일치 판독의 임상적 의의를 세부전공분야와 촬영장비별로 평가하고자 하였다. 대상과 방법 한 국내 원격판독 의료기관에서 2018년과 2019년에 시행한 동료평가를 대상으로 세부전공분야와 촬영장비별로 판독 불일치를 분석하였다. 동료평가 점수를 적격 진단과 부적격 진단으로 분류하였고, 판독 불일치는 임상적 의의에 따라 무의한 불일치와 유의한 불일치로 분류하였다. 카이제곱 검증으로 통계를 시행하였다. 결과 총 1312건의 동료평가 중 부적격 진단은 117건(8.9%)이고, 총 462건의 진단 불일치 중 유의한 불일치는 104건(21.6%)이었다. 세부전공분야에서 부적격 진단율은 근골격(21.4%)이 가장 높았고(각각 p < 0.05), 복부(7.3%)는 신경두경부(1.3%)에 비해 높았다(p < 0.05). 유의한 불일치는 흉부(32.7%)가 복부(17.1%)와 근골격(19.5%)에 비해 높았다(각각 p < 0.05). 촬영장비에서 부적격 진단은 MR (16.2%)이 일반촬영(7.8%)에 비해 높았고(p < 0.05), 유의한 불일치는 차이가 없었다. 결론 동료평가를 통해서 원격판독의 부적격 진단과 임상적 유의한 불일치의 정도, 세부전공분야와 촬영장비에 따른 차이를 알 수 있었다.

인장웨브재 형태에 따른 각형강관 갭K형 접합부의 거동 비교 (Comparison on the Behavior according to Shapes of Tension Web member in gap K-joints in Cold-formed Square Hollow Sections)

  • 정상민;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.561-568
    • /
    • 2005
  • 본 논문의 목적은 트러스 인장웨브재의 형상이 정방형 각형강관인 기존 연구(강관웨브형)와 고장력 강봉을 인장웨브재로 사용하기 위해 연결플레이트를 가지는(강봉웨브형) 냉간성형 각형강관 갭 K형 접합부의 거동 비교를 통하여 고장력 강봉 사용의 적정성을 알아보기 위한 것이다. 주관폭두께비가 33.3으로 동일한 강관웨브형 실험체 4개와 강봉웨브형 실험체 8개의 최대내력, 파괴모드, 초기강성, 연성율 등을 비교하였다. 비교 결과, 접합부의 내력은 강관웨브형에서는 압축지관의 선행파괴로 결정되었으며, 강봉웨브형에서는 인장측의 선행파괴로 결정되었다. 무차원화 내력은 동일 폭비에서 강관웨브형이 높게 나타났으며, 폭비 증가에 따른 내력증가현상도 강관웨브형에서 뚜렷하게 나타나고, 강봉웨브형은 일정한 경향이 나타나지 않은 반면에 인장과 압축폭비로 나누어 살펴보면 인장폭비 증가에 따라서는 선형적인 증가현상이 나타남을 알았다. 파괴모드는 강관웨브형의 경우에는 압축지관의 미소 국부좌굴과 인장웨브와 주관 접합면의 소성파괴가 나타났고, 강봉웨브형의 경우는 주관플랜지면 소성변형 후 연결플레이트 용접부위의 파단이 나타났다. 따라서, 강봉웨브형에서 연결 플레이트를 갖는 갭K형 접합부의 경우에는 강관웨브형에 비해 주관의 폭두께비를 낮게 할 필요가 있으며, 폭비도 인장지관과 압축지관과의 관계를 고려하여 결정하여야 할 것으로 판단된다.

지지격자가 있는 봉다발과 축방향으로 평행한 유동의 압력손실에 관한 실험적 연구 (Experimental Study on Pressure Loss of Flow Parallel to Rod Bundle with Spacer Grid)

  • 이치영;신창환;박주용;인왕기
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.689-695
    • /
    • 2012
  • 지지격자가 있는 봉다발과 축방향으로 평행한 유동에서, 봉다발 마찰계수와 지지격자 손실계수를 평가하였다. 시험부는 외경 9.5 mm, 길이 2000 mm 인 봉 25 개를 $5{\times}5$ 정사각 구조로 배열하여 제작하였으며, 봉 중심간 거리와 봉 외경의 비는 1.35 였다. 지지격자로는 plain 지지격자, split-vane 지지격자, hybrid-vane 지지격자를 이용하였다. 지지격자가 없는 봉다발의 마찰계수는 기존 상관식과 비교적 잘 일치하였다. 지지격자가 있는 봉다발 실험의 경우, hybrid-vane 지지격자에서 봉다발 마찰계수 및 지지격자 손실계수가 가장 크게 측정되었으며, 이는 지지격자의 유동단면 막음비 증가와 혼합날개 형상에 의한 유동 교란이 증가되기 때문인 것으로 판단된다. Re=$5{\times}10^5$ 조건에서 plain 지지격자, split-vane 지지격자, hybrid-vane 지지격자의 손실계수는 약 0.79, 0.80, 0.88 로 예측되었다.