• Title/Summary/Keyword: Square rods

Search Result 40, Processing Time 0.03 seconds

Heat Transfer Characteristics of Confined Slot Jet Impingement on a Flat Plate with Square Rods (사각봉이 배열된 슬롯제트 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) clearance(c) between square rods and the plate, and the length(d) of a side of the square rod were examined. Measurement or heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region.

  • PDF

Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods (사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향)

  • Chung, In-Kee;Park, Si-Woo;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

Cyclic test of buckling restrained braces composed of square steel rods and steel tube

  • Park, Junhee;Lee, Junho;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.423-436
    • /
    • 2012
  • In this study total of six buckling-restrained braces (BRBs) were manufactured using a square steel rod as a load-resisting core member and a hollow steel tube as restrainer to prevent global buckling of the core. The gap between the core and the tube was filled with steel rods as filler material. The performances of the proposed BRB from uniaxial and subassemblage tests were compared with those of the specimens filled with mortar. The test results showed that the performance of the BRB with discontinuous steel rods as filler material was not satisfactory, whereas the BRBs with continuous steel rods as filler material showed good performance when the external tubes were strong enough against buckling. It was observed that the buckling strength of the external tube of the BRBs filled with steel rods needs to be at least twice as high as that of the BRBs filled with mortar to ensure high cumulative plastic deformation of the BRB.

Effect of Turbulence Promoter Width on Heat Transfer Augmentation in Impinging Air Jet System (충돌공기분류계(衝突空氣噴流系)에서 난류촉진체(亂流促進體)의 폭변화(幅變化)가 전열증진(傳熱增進)에 미치는 영향(影響))

  • Kum, S.M.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.427-438
    • /
    • 1994
  • This experimental study was earned out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods and to find out the optimum rods arrangement. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow.

  • PDF

Heat Transfer Characteristics by Rods in Transition Region of Impinging Air Jet (충돌제트 천이영역에서 로드에 의한 열전달특성)

  • Kum, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • This research has been proceeded over the transition region(H/B=10) of two-dimensional impinging air jet system, in which square rods has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in cases the clearance from rods to heating surface(C=1, 2, 4, 6 mm) and the width of rods(W=4, 6, 8 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C=1 mm, and as the width is 8 mm, it is largely influenced by eddies and acceleration in case width of rods changed.

An Experimental Study on Heat Transfer Augmentation by Square Rod in Impinging Air Jet System(Effect of Rod Width) (사각로드를 이용한 충돌분류계의 열전달증진에 관한 연구(로드폭의 영향))

  • Kum, Seong-Min;Lee, Yong-Hwa;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.127-140
    • /
    • 1995
  • This experimental study was carried out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow. When rods are installed in front of the plate, the acceleration of the flow and the turbulence generation due to the rods and reattachment of the flow seem to contribute to the observed heat transfer augmentation and the heat transfer augmentation increases as the clearance decreases. With wider individual rod the heat transfer coefficient is higher, which is due to the increased acceleration and development of the eddies just before the rods.

  • PDF

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;김점식;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

Effect of Heat Transfer Augmentation by Square Rod Array in Impinging Air Jet System(Heat Transfer Characteristic of Potential Core Region) (충돌공기분류계에서 사각 ROD에 의한 전열증진 효과(포텐셜코어영역에서의 전열특성))

  • Kum, Seong-Min;Oh, Soo-Cheol;Seo, Jeong-Yoon
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 1995
  • This research has been proceeded over the potential core region(H/B=2) of two-dimensional impinging air jet sytem, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in eases of the clearance from rods to heating surface(C=1, 2, 4, 6 mm) and the pitch between each rods(P=30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C=1mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed.

  • PDF

A Study on the Flow Characteristics according to the Shapes of Rod on Impinging Jet by PIV Measurement (충돌 Jet에서 Rod 형상에 따른 유동특성의 PIV 계측에 의한 연구)

  • 나우정;정진도;송민근;이상범;손승우;주은선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.152-161
    • /
    • 2004
  • The thermal load is a very important problem to be solved in many industrial systems including the electronic equipment. Impinging Jets have been known to provide a large heat transfer rates on surface for many years. The turbulence enhancement of fluid flow is requested for the efficiency elevation of heat transfer. A study on flow fields by rods attached to the wall surface as a promoter of turbulence enhancement has been carried out. The exact analysis on chracteristics of impinging jet field is requested to obtain the optimum design of the impinging jet system. By visualizing the flow field and processing the high digital image by computer PIV can afford exact data on the velocity vector kinetic energy and turbulence intensity in the complex turbulence field. In this study. three kinds of rod shape such as square. triangle. and semicircle are selected as the turbulence promoter. Nozzle diameters are 10mm. 17mm. and 23mm. And the analysis of the flow characteristics due to the above rods is carried out at Re No. 2.000, 3.000. and 4,000 by PIV measurement. It is clarified that the rod setup is very useful to obtain the turbulence enhancement and the turbulence intensity according to the shapes of rod appears large in order of the shapes of rod such as square 〉 triangle 〉semicircle.