• Title/Summary/Keyword: Square law Detector

Search Result 20, Processing Time 0.028 seconds

A Programmable Doppler Processor Using a Multiple-DSP Board (다중 DSP 보드를 이용한 프로그램 가능한 도플러 처리기)

  • 신현익;김환우
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.5
    • /
    • pp.333-340
    • /
    • 2003
  • Doppler processing is the heart of pulsed Doppler radar. It gives a clutter elimination and coherent integration. With the improvement of digital signal processors (DPSs), the implementation using them is more widely used in radar systems. Generally, so as for Doppler processor to process the input data in real time, a parallel processing concept using multiple DSPs should be used. This paper implements a programmable Doppler processor, which consists of MTI filter, DFB and square-law detector, using 8 ADSP21060s. Formulating the distribution time of the input data, the transfer time of the output data and the time required to compute each algorithm, it estimates total processing time and the number of required DSP. Finally, using the TSG that provides radar control pulses and simulated target signals, performances of the implemented Doppler processor are evaluated.

Analysis of Improved Cyclostationary Spectrum Sensing with SLC Diversity over Composite Multipath Fading-Lognormal Shadowing Channels

  • Zhu, Ying;Liu, Jia;Feng, Zhiyong;Zhang, Ping
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.3
    • /
    • pp.799-818
    • /
    • 2014
  • Spectrum sensing is a key technical challenge for cognitive radio (CR). It is well known that multi-cycle cyclostationarity (MC) detector is a powerful method for spectrum sensing. However, conventional MC detector is difficult to implement due to its high computational complexity. This paper pays attention to the fact that the computation complexity can be reduced by simplifying the test statistic of conventional MC detector. Based on this simplification process, an improved MC detector is proposed. Compared with the conventional one, the proposed detector has the low-computational complexity and sufficient-accuracy on sensing performance. Subsequently, the sensing performances are further investigated for the cases of Rayleigh, Nakagami-m, Rician, composite Rayleigh fading-lognormal shadowing and composite Nakagami fading-lognormal shadowing channels, respectively. Furthermore, the square-law combining (SLC) is introduced to improve the detection capability over fading-shadowing channels. The corresponding closed-form expressions of average detection probability are derived for each case by the moment generation function (MGF) approach. Finally, illustrative and analytical results show that the efficiency and reliability of proposed detector and the improvement on sensing performance by SLC over composite fading-shadowing channels.

A Detection Scheme for Random Signals under Dependent Noise Environment (종속 잡음 환경에서 확률 신호 검파 방식)

  • Kim, Kwang-Soon;Won, Dae-Han;Song, Iick-Ho;Yun, Hyung-Sik;Lee, Ju-Mi;Kim, Sun-Yong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.69-75
    • /
    • 2000
  • In this paper, we consider the problem of discrete-time random signal detection problem under the presence of additive noise exhibiting weak dependence The test statistic of the locally optimum detector for correlated random signals under a weakly dependent noise model is derived The performance characteristic of the locally optimum detector is analyzed and compared with that of the square-law detector in terms of the asymptotic relative efficiency.

  • PDF

Design of a Radiation Spectroscopy Detector using a Spherical Scintillator and Development of a Radiation Source Position Tracking System (구형의 섬광체를 이용한 방사선 스펙트로스코피 검출기 설계 및 방사선원 위치 추적 시스템 개발)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • A radiation spectroscopy detector using a spherical scintillator was designed, and a system was developed to track the position of a radiation source using several detectors. The position tracking algorithm was designed based on the theory that the number of radiations decreases according to the inverse square law of distance, and the position of the radiation source was calculated by measuring the number of radiations generated from the radiation sources at various positions. The radiation generated from the radiation source is detected by different coefficients in each detector, and the difference between these detected coefficients varies in proportion to the inverse square of the distance. Geant4 Application for Tomographic Emission (GATE) simulation was performed to verify and evaluate the performance of the designed radiation source position tracking system, and radiation generated from radiation sources placed at different positions was counted with each detector. The number of measured radiations was tracked through the radiation source position tracking algorithm, and the error between the actual radiation source position and the position calculated by the algorithm was evaluated. The error between the position of the actual radiation source and the calculated position was measured as an average of 0.11% on the X-axis and 0.37% on the Y-axis, and it was verified that the position can be measured very accurately.

Effects of the Phase Noise in the Frequency Synthesizer on the SFH/M-NCFSK System (주파수 합성기의 위상 잡음이 SFH/M-NCFSK 시스템에 미치는 영향)

  • 손종원;이준서;유흥균;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.685-691
    • /
    • 2003
  • This paper newly analyzes the effect of the phase noise in the frequency synthesizer on the performance of SFH/M-NCFSK system by standard frequency deviation(equation omitted) when noncoherent FSK demodulation of the square-law detector is considered. We derive the SER in the SFH system and analyze the effect of phase noise on the SFH/M-NCFSK system performance according to the hopping frequency spacing (1/T$\_$h/) and the variation of the standard frequency deviation (equation omitted). The required SNR is about 13.4 dB to meet Ps=10$\^$-3/ when the standard frequency deviation is about 4.0 Hz and the hopping frequency spacing (1/T$\_$h/) in the SFH/2-NCFSK system is 30. So, there is about 2.4 dB power penalty than the phase noise-free system. If the hopping frequency spacing 1/T$\_$h/ is under 30, the error floor may happen and SER considerably grows up. We show that the analytic results closely match with the simulation results.

Design of a W-band Radiometer Simultaneously Operating with a Single-Antenna Configured FMCW Radar (단일 안테나를 사용하는 FMCW 레이더와 동시 운용이 가능한 W-대역 레디오미터 설계)

  • Jung Myung-Suk;Kim Wan-Joo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.4 s.346
    • /
    • pp.67-74
    • /
    • 2006
  • We present the design of a radiometer in W-band which operates simultaneously with a single antenna configured FMCW radar. We choose a total power radiometer(TPR) which shares an antenna and a front-end with the radar for miniaturizing the system. We separate the radiometer signal from the radar signal using a diplexer in IF band. Because the radiometer has an unwanted transmitter section due to the common use of the MMW front-end with the radar, some additional noise signals caused by the transmitter degrade the sensitivity of the radiometer system. To compensate the degradation of sensitivity, we use matching circuits and a diode detector configured as the voltage doubler. Through some experiments, we have verified that the designed radiometer system has good performances in detecting metal targets tying at several hundred meters.

Performance Improvement in Optical CDMA System Under The Presence of Beat Noise Using a Cancellation Method

  • Benaree, Warut;Noppanakeepong, Suthichai;Leelaruji, Nipha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1206-1210
    • /
    • 2005
  • This paper presents performance improvement in optical CDMA system under the presence of beat noise using a cancellation technique. Optical fibers and atmospheric optical communications have been proposed the connection between base stations and central station. The optical signal beat noise is due to interference between lightwave, many optical waves are simultaneously incident on each receiver photodiode. Since the photodiode acts as a square-law detector, beat noise can occur in the receiver. While A two-stage cancellation technique is analyzed and verified via simulation employed here because of its system simplicity. By using the random ingredients of all user signals are estimated, the beat noise is rebuilt and removed from the intended signal. In addition to cancellation technique cancel the inherent multiuser interference (MUI) in CDMA system and nonlinear distortion (NLD) in optical system. It is performed at the receiver of the central station where the random ingredients of all user signals are estimated and the MUI and the NLD are rebuilt and removed from the received signal. The validity of the cancellation technique is theoretically analyzed and shown by numerical results. The increasing of capacity in two stage cancellation are obtained.

  • PDF

Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer (자궁경부암의 강내치료를 위한 선량측정)

  • 김진기;김정수;김형진;권형철
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • Dose distribution of HDR-RALS source represents an inverse square law as the distance. Difference of measurement value and calculation value according of brachytherapy. Therefore, in HDR-RALS dose calibration and calculation have an important effect in treatment of uterine cervical cancer and absorbed dose of interesting points. In intracavitary therapy, particula attention is paid for precise determination of the doses to be applied. In this report, we have discussed that the calibration of a HDR-RALS, differences between calculation dose use of isodose chart and measurement in rectum. Dose rate calibration of radiation sources are obtained from air kerma and Г factor with calibraed ion chamber for cobalt source. and used semiconductor detector for compared with measurement in phantom. Eighteen patients were treated with a HDR-RALS for intrcavitarty irradiation (ICR) using a cobalt-cesium source. Repoductivity of dose measurements were 0.3 -1.1% in phantom. The means of dose distribution was -6- +21% between calculation of isodose chart and measurement of recyum, and was same mean value upper 6.3% in measurement value than calculation does.

  • PDF

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF