• Title/Summary/Keyword: Square Wave Voltammetry

Search Result 75, Processing Time 0.025 seconds

Electrochemical Assay of Neurotransmitter Glycine in Brain Cells

  • Ly, Suw-Young;Kim, Dong-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.515-519
    • /
    • 2007
  • Neurotransmitter glycine in the nano gram range was analyzed using a paste electrode (PE) in cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV). An anodic peak caused by oxidation of the glycine ion appeared at the 0.4 V (versus Ag/AgCl/KCl) potential in a 0.1 M NH4H2PO4 electrolyte solution. At optimized conditions, the working range of the SWSV and CV concentration was found to be 5-60 ngL-1 glycine; precision of R2 = 0.9816 (SWSV) and 0.9986 (CV); and detection limit of 0.65 ngL-1 (5.82 × 10-12 molL-1) (S/N = 3). The optimized conditions were applied to an assay in a fish brain tissue and a living brain cell in real time.

Antibiotics Assay of Doxycycline in Food System using Stripping Voltammetry

  • Ly, Suw Young;Lee, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.726-733
    • /
    • 2016
  • A voltammetric analysis of doxycycline was developed using DNA immobilized onto a carbon nanotube paste electrode (PE). An anodic peak current was indicated at 0.2 V (versus Ag/AgCl) in a 0.1M $NH_4H_2PO_4$ electrolyte solution. The linear working range of the cyclic and square wave stripping voltammetry was obtained to $1-27ngL^{-1}$ with an accumulation time of 800 s. Final analytical parameters were optimized to be as follows: amplitude, 0.35 V; frequency, 500 Hz; and pH, 5.43. Here detection limit was found to be $0.45ngL^{-1}$, this result can be applied in foods systems and in the biological diagnostics

Redox Reaction of Multivalent Ions in Glass Melts

  • Kim, Kidong
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.83-91
    • /
    • 2015
  • The redox reaction $M^{(x+n)+}+\frac{n}{2}O^{-2}{\rightleftarrows}M^{x+}+\frac{n}{4}O_2$ of multivalent ions in glass melts influences the melting process and final properties of the glass including the fining (removal of bubbles), infrared absorption and homogenization of melts, reaction between metal electrodes and melts or refractory and melts, and transmission and color of glass. In this review paper, the redox behaviors that occur frequently in the glass production process are introduced and the square wave voltammetry (SWV) is described in detail as an in situ method of examining the redox behavior of multivalent ions in the melt state. Finally, some voltammetry results for LCD glass melts are reviewed from the practical viewpoint of SWV.

Diagnostic ex vivo assay of glucose in live cell using voltammetry

  • Ly, Suw Young;Leea, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1379-1385
    • /
    • 2018
  • The hand held voltammetry systems searched diabetic assay using glucose sensor of fluorine nafion doped carbon nanotube electrode (FCNE). An inexpensive graphite carbon pencil was used as an Ag/AgCl reference and Pt counter electrode. Upon combining and using three electrode systems, optimum square wave (SW) stripping results were attained to 1.0-9.0 ug/L with 8 points. Statistic RSD precision was of 6.02 % with n=15 in 0.1 mg/L glucose. After a total of 200 second accumulation times, analytical detection limit of 0.8 ug/L was obtained. This developed technique was applied to urine samples from diabetic patients urine for fluid analysis, it was determined that the sensor can be used with a diagnostics in the ex vivo of live cells and non treated biological fluid.

Electrochemical Behaviors and Square Wave Voltammetric Determinations of Cefotaxime Sodium and Ceftriaxone Sodium (세포탁심나트륨과 세프트리악손나트륨의 전기화학 거동 및 네모파 전압전류법 정량)

  • Kim, Min-Kyung;Hahn, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.50 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Square wave voltammetric (SWV) and cyclic voltammetric (CV) behaviors of cefotaxime sodium and ceftriaxone sodium have been investigated in the potential range between -0.10 V and -1.30 V using the phosphate buffers of various pH values ($2.00{\sim}9.10$). Two main peaks observed were irreversible and protons were involved in their electrochemical reductions. The first peaks of these cephalosporin antibiotics are due to the reduction of the azomethine double bond in the methoxyimino group of the side chain at position 7. The second peaks of cefotaxime sodium and ceftriaxone sodium are related to the reductions of the ${\Delta}^3$ double bond and the dioxo moiety of the side chain at position 3, respectively. The calibration curve of cefotaxime sodium in the concentration range between $1.0{\times}10^{-7}M$ and $1.0{\times}10^{-5}M$ yielded the linearity with the correlation coefficient of 0.9998 when the first peak of the antibiotic in a phosphate buffer of pH 3.02 was measured at the conditions of frequency of 120 Hz and pulse height of 50 mV by SWV. The present fast, simple and accurate SWV assay method was applied to determine cefotaxime sodium in the commercial antibiotic powder of injection.

A Simple Fast Analog Storage Device and Its Applications (간단한 Analog 기억장치의 제작과 그 응용)

  • In Tae Bae;Q. Won Choi;Ha Suck Kim
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • An inexpensive, yet convenient analog storage device was constructed. Sequentially MOSFET-switched 20 sample and holds equipped with a high input impedance preamplifier were parallelly matched to the digitally controlled shift register system in variable speeds up to 3 kHz. To verify its usefulness, square wave train, sinusiodal wave and some electrochemical data, such as fast-scan voltammogram and transient current-time curves of differential pulse polarography were tested.

  • PDF

Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Jung, Min-Ki;Ko, Kwang-Hee;Kim, Byung-Jin;Lee, Ki-Chul;Choi, Byung-Min
    • Toxicological Research
    • /
    • v.26 no.3
    • /
    • pp.233-236
    • /
    • 2010
  • The analytical in vivo chromium ion was searched for using a voltammetric hollow-fiber dialysis sensor via square wave stripping voltammetry (SW), cyclic voltammetry (CV), and chronoamperometry. Under optimum parameters, the analytical results indicated linear working ranges of 50~400 mg/l CV and $10{\sim}80\;{\mu}g/l$ SW within a 30-sec accumulation time. The analytical detection limit (S/N) was $6.0\;{\mu}g/l$. The developed method can be applied to in vivo tissues and in ex vivo toxicity assay, as well as to other materials that require chromium analysis.

Voltammetric Assay of Antibiotics for Modified Carbon Nanotube Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Lee, Chang-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.443-449
    • /
    • 2012
  • A investigation of electrochemical analysis of antibiotics Neomycin ($C_{23}H_{46}N_6O_{13}$) was searched using electrochemical square wave (SW) stripping and cyclic voltammetry (CV) using working sensor of the modified carbon nanotube combination electrodes, optimum diagnostic parameters were searched by anodic stripping, final conditions were attained to working range of 1.0-14.0 ng/L, detection limit (S/N) was found to be 0.6 ng/L. The developed method was discovered to be fitting in quality control in the food, pharmaceutical and other manufacturing sectors.

Electrochemical Detection of Trace Level Copper in in vivo Cell (생체 세포내 미량 구리의 전기화학적 검출에 관한 연구)

  • Lee, Chang-Hyun
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1333-1338
    • /
    • 2012
  • In order to measure the minute amount of Cu(II) in our environment, cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV) were performed for a trace copper assay using bismuth immobilized on a carbon nanotube paste electrode. An analytical working range of 30 to $240{\mu}g/L$ Cu(II) was obtained for CV and SWSV. The SWSV precision obtained was 0.47 % (n = 15) RSD in $30.0{\mu}g/L$ Cu(II). The detection limit obtained was 3.1 ng/L Cu(II) using SWSV, while the CV yielded the nano-range detection limit through the pre-concentration step. By using this research method, Cu(II) value could be determined in the urine of human sample and in the brain of fish sample. This research can be effectively applied to other cases of measuring minute amount of Cu(II) in living organisms.

Electrochemical oxidation-reduction and determination of urea at enzyme free PPY-GO electrode

  • Mudila, Harish;Prasher, Parteek;Rana, Sweta;Khati, Beena;Zaidi, M.G.H.
    • Carbon letters
    • /
    • v.26
    • /
    • pp.88-94
    • /
    • 2018
  • This manuscript explains the effective determination of urea by redox cyclic voltammetric analysis, for which a modified polypyrrole-graphene oxide (PPY-GO, GO 20% w/w of PPY) nanocomposite electrode was developed. Cyclic voltammetry measurements revealed an effective electron transfer in 0.1 M KOH electrolytic solution in the potential window range of 0 to 0.6 V. This PPY-GO modified electrode exhibited a moderate electrocatalytic effect towards urea oxidation, thereby allowing its determination in an electrolytic solution. The linear dependence of the current vs. urea concentration was reached using square-wave voltammetry in the concentration range of urea between 0.5 to $3.0{\mu}M$ with a relatively low limit of detection of $0.27{\mu}M$. The scanning electron microscopy was used to characterize the morphologies and properties of the nanocomposite layer, along with Fourier transform infrared spectroscopy. The results indicated that the nanocomposite film modified electrode exhibited a synergistic effect, including high conductivity, a fast electron-transfer rate, and an inherent catalytic ability.