• 제목/요약/키워드: Square Cross-Section

검색결과 233건 처리시간 0.02초

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage

  • Kim, Noh-Yu;Achenbach, J.D.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.417-426
    • /
    • 2006
  • A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also introduced to overcome distortion of the Compton backscatter data due to attenuation effects attributed to beam hardening and quantum noise.

DICOM 영상과 설계 모델링을 융합한 외이도의 형태적 변화 관찰 연구 (An Observational Study on the Morphological Changes of the External Ear Canal by Converging DICOM Imaging and Design Modeling)

  • 김형균
    • 한국융합학회논문지
    • /
    • 제10권11호
    • /
    • pp.173-179
    • /
    • 2019
  • DICOM 영상은 인체의 진단과 치료에 중요한 역할을 하고 있으며 설계모델링은 목적에 따라 형상을 3차원으로 계획하는 기술이다. 본 연구는 이러한 두 가지 기술을 융합하여 외이도의 형태적 변화에 대한 횡단면, 부피, 표면적의 관계를 관찰하고자 하였다. 실험은 인체의 단면 획득 의료영상기술을 적용하여 19귀의 외이도를 추출한 3차원 형상을 스테레오리소그래피, 3-매틱(matic) 프로그램으로 센터라인 생성 및 분할 기술을 적용하였다. 그 결과 외이도의 횡단면 구조는 타원형(38.5%), 반원형(28.2%), 혼재형(17.9%), 네모형(10.2%), 주름형(5.1%)등 다양한 형태가 나타났다. 또한 외이도 길이가 길수록 위상별 횡단면 면적은 크게 나타났으며 부피와 표면적은 고막방향으로 갈수록 감소하였지만 그 감소율은 상대적으로 낮게 나타났다. 이는 외이도의 형태가 고막방향으로 갈수록 불규칙한 구조로 되어 있음을 나타냈다.

Peak Pressures Acting on Tall Buildings with Various Configurations

  • Bandi, Eswara Kumar;Tanaka, Hideyuki;Kim, Yong Chul;Ohtake, Kazuo;Yoshida, Akihito;Tamura, Yukio
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.229-244
    • /
    • 2013
  • Twenty six pressure models of high rise buildings with various cross-sections including twisted models were tested in a boundary layer wind tunnel. The cross-sections were triangular, square, pentagon, hexagon, octagon, dodecagon, circular, and clover. This study investigates variations in peak pressures, and effects of various cross-sections and twist angles on peak pressures. To study the effects of various configurations and twist angles on peak pressures in detail, maximum positive and minimum negative peak pressures at each measurement point of the building for all wind directions are presented and discussed. The results show that peak pressures greatly depend on building cross-section and twist angle.

Compressive performances of concrete filled Square CFRP-Steel Tubes (S-CFRP-CFST)

  • Wang, Qingli;Shao, Yongbo
    • Steel and Composite Structures
    • /
    • 제16권5호
    • /
    • pp.455-480
    • /
    • 2014
  • Sixteen concrete filled square CFRP-steel tubular (S-CFRP-CFST) stub columns under axial compression were experimentally investigated. The experimental results showed that the failure mode of the specimens is strength loss of the materials, and the confined concrete has good plasticity due to confinement of the CFRP-steel composite tube. The steel tube and CFRP can work concurrently. The load versus longitudinal strain curves of the specimens can be divided into 3 stages, i.e., elastic stage, elasto-plastic stage and softening stage. Analysis based on finite element method showed that the longitudinal stress of the steel tube keeps almost constant along axial direction, and the transverse stress at the corner of the concrete is the maximum. The confinement effect of the outer tube to the concrete is mainly focused on the corner. The confinements along the side of the cross-section and the height of the specimen are both non-uniform. The adhesive strength has little effect both on the load versus longitudinal strain curves and on the confinement force versus longitudinal strain curves. With the increasing of the initial stress in the steel tube, the load carrying capacity, the stiffness and the peak value of the average confinement force are all reduced. Equation for calculating the load carrying capacity of the composite stub columns is presented, and the estimated results agree well with the experimental results.

정방형 실린더 주위 유동패턴에 대한 자유수면의 영향 (EFFECTS OF THE FREE SURFACE ON THE FLOW PATTERN PAST A SQUARE CYLINDER)

  • 안형수;양경수
    • 한국전산유체공학회지
    • /
    • 제22권1호
    • /
    • pp.81-87
    • /
    • 2017
  • The characteristics of flow past a square cylinder submerged under the free surface have been numerically studied. An immersed boundary method was adopted for implementation of the cylinder cross-section in a Cartesian grid system. Also, a level-set method was used to capture the interface of the two fluids. The case for Reynolds number 150 was examined. At the specific Reynolds number, by varying the gap ratio(0.25, 0.40, 0.55, 0.70, 1.00, 1.50, 2.50, 5.00) the effects of the free surface on the force coefficients and Strouhal number of vortex shedding were identified. The presence of the free surface very close to the cylinder significantly affects the shedding pattern, resulting in considerable deviation of the force coefficients and Strouhal number from those of the single-phase flow. In addition, the influence of Froude number was considered in this study. By increasing Froude number(0.2-0.4), flow topology change was identified at the specific gap ratios(0.40, 0.70, 1.50, 5.00).

2차원(次元) 충돌분류(衝突噴流)의 열전달(熱傳達) 증진(增進)에 관(關)한 실험적(實驗的) 연구(硏究) (사각(四角) Rib폭(幅)의 효과(效果)) (Augmentation of Heat Transfer by two Dimensional Impinging Air Jet (Effect of Square Rib Width))

  • 이용화;이관석;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.350-356
    • /
    • 1988
  • The impinging air jet system is still being used in the various fields with its inherent merits, that is, the easiness in engineering application and high heat transfer coefficients at stagnation point. The purpose of this study is augmentation of heat transfer without additional power in the rectangular air jet which impinges vertically to the heating surface. As a method of passive heat transfer augmentation in a two-Dimensional impinging jet, the transverse-repeated surface roughness of square cross-section is used. This paper deals with the experimental study on the characteristics of heat transfer at the x-direction in between nozzle exit and heating surface of flat plate, and that of ribbed plate. And this study also investigates the effect of square rib widths. The integral average heat transfer coefficient of ribbed plate is about 2.2 times larger than that of flat plate.

  • PDF

Flexural performance of cold-formed square CFST beams strengthened with internal stiffeners

  • Zand, Ahmed W. Al;Badaruzzaman, W.H. Wan;Ali, Mustafa M.;Hasan, Qahtan A.;Al-Shaikhli, Marwan S.
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.123-139
    • /
    • 2020
  • The tube outward local buckling of Concrete-Filled Steel Tube (CFST) beam under high compression stress is still considered a critical problem, especially for steel tubes with a slender section compared to semi-compact and compact sections. In this study, the flexural performance of stiffened slender cold-formed square tube beams filled with normal concrete was investigated. Fourteen (14) simply supported CFST specimens were tested under static bending loads, stiffened with different shapes and numbers of steel stiffeners that were provided at the inner sides of the tubes. Additional finite element (FE) CFST models were developed to further investigate the influence of using internal stiffeners with varied thickness. The results of tests and FE analyses indicated that the onset of local buckling, that occurs at the top half of the stiffened CFST beam's cross-section at mid-span was substantially restricted to a smaller region. Generally, it was also observed that, due to increased steel area provided by the stiffeners, the bending capacity, flexural stiffness and energy absorption index of the stiffened beams were significantly improved. The average bending capacity and the initial flexural stiffness of the stiffened specimens for the various shapes, single stiffener situations have increased of about 25% and 39%, respectively. These improvements went up to 45% and 60%, for the double stiffeners situations. Moreover, the bending capacity and the flexural stiffness values obtained from the experimental tests and FE analyses validated well with the values computed from equations of the existing standards.

Experimental and numerical investigation of strengthened deficient steel SHS columns under axial compressive loads

  • Shahraki, Mehdi;Sohrabi, Mohammad Reza;Azizyan, Gholam Reza;Narmashiri, Kambiz
    • Structural Engineering and Mechanics
    • /
    • 제67권2호
    • /
    • pp.207-217
    • /
    • 2018
  • In past years, numerous problems have vexed engineers with regard to buckling, corrosion, bending, and overloading in damaged steel structures. This article sets out to investigate the possible effects of carbon fiber reinforced polymer (CFRP) and steel plates for retrofitting deficient steel square hollow section (SHS) columns. The effects of axial loading, stiffness, axial displacement, the position and shape of deficient region on the length of steel SHS columns, and slenderness ratio are examined through a detailed parametric study. A total of 14 specimens was tested for failure under axial compression in a laboratory and simulated using finite element (FE) analysis based on a numerical approach. The results indicate that the application of CFRP sheets and steel plates also caused a reduction in stress in the damaged region and prevented or retarded local deformation around the deficiency. The findings showed that a deficiency leads to reduced load-carrying capacity of steel SHS columns and the retrofitting method is responsible for the increase in the load-bearing capacity of the steel columns. Finally, this research showed that the CFRP performed better than steel plates in compensating the axial force caused by the cross-section reduction due to the problems associated with the use of steel plates, such as in welding, increased weight, thermal stress around the welding location, and the possibility of creating another deficiency by welding.

철근콘크리트 기둥의 좌굴거동에 관한 실험적 연구 (Experiments for the Buckling Behavior of Reinforced Concrete Columns)

  • 조성찬;장정수;김진근;김윤용;김광석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.284-289
    • /
    • 1993
  • To analyze the effects of compressive strength of concrete and longitudinal steel ratio on buckling behavior of columns, 36tied reinforced concrete columns with hinged ends were tested. The 100mm square cross section was used and the amount of eccentricity was 10mm. The compressive strengths of column specimens with slenderness ratios of 15, 30 and 50 were 202, 513 and 752 kg/$\textrm{cm}^2$. The longitudinal steel ratio of columns with bending about a section diagonal and about a principal axis were 2.85%(4-D10). The ratio of ultimate load capacity to that of short column with the same eccentricity was much decreased at high slenderness ratio with increasing the compressive strength of concrete. And the lateral displacement of column at the ultimate load was decreased as the strength was increased. These are due to that at high slenderness ratio, the load capacity and behavior of column are affected by flexural rigidity. And, it was also found that for the same quantity of confining steel and level of axis load, there is little difference between the flexural strength for bending about a section diagonal and for bending about principal axis.

  • PDF

내화성능 개선을 위한 강섬유 보강 내부 앵커형 각형강관 합성기둥의 실험연구 (An Experimental Study of Improving Fire Performance with Steel-fibers for Internally Anchored Square Composite Columns)

  • 김선희;염경수;김용환;최성모
    • 한국강구조학회 논문집
    • /
    • 제26권6호
    • /
    • pp.499-509
    • /
    • 2014
  • 본 연구에서는 해결방안으로 내부 콘크리트를 강섬유와 혼입하여 기둥자체의 연성과 인성을 증대시키는 것에 중점을 맞추고 있다. 즉, 강섬유 혼입량과 하중조건에 따른 내력 및 변형능력을 종합적으로 파악하여 강섬유 콘크리트와 용접조립각형 강관기둥의 상호작용을 구조, 내화측면에서 분석해 보고자 한다. 동일한 형상과 경계조건(하중비)에서 강섬유 혼입(0.375%)으로 내화성능은 약 1.1~1.3배 향상된 실험결과를 얻을 수 있었다. 강섬유 콘크리트의 균열 억제 특성은 열 하중에 의한 콘크리트의 변형저항 성능을 증가 시키면서 내화성능의 향상을 가져온 것으로 판단된다. 또한, 내부 리브의 열 변형에도 내부 콘크리트 단면은 건전한 상태로 남아있어 하중 분담능력이 증폭된 결과로 분석됐다.