An Experimental Study of Improving Fire Performance with Steel-fibers for Internally Anchored Square Composite Columns  

Kim, Sun Hee (Department of Architectural Engineering, University of Seoul)
Yom, Kong Soo (Harmony Structural Engineering)
Kim, Yong Hwan (Department of Architectural Design, Kyun-dong University)
Choi, Sung Mo (Department of Architectural Engineering, University of Seoul)
Publication Information
Journal of Korean Society of Steel Construction / v.26, no.6, 2014 , pp. 499-509 More about this Journal
Abstract
This study focuses on mixing steel fiber in the concrete to improve the ductility and toughness of the columns. The purpose of the study is to evaluate the load capacity and deformation capacity associated with the amount of steel fiber and loading condition and to analyze the interplay between the steel fiber reinforced concrete and the welding built-up square tube in terms of structure and fire resistance performance. Reinforcement of concrete with steel fiber(Vf=0.375%), when cross-section shape and boundary condition (load ratio) remained unchanged, improved fire resistance performance by 1.1~1.3 times. It is deemed that the area resisting thermal load increased and fire resistance performance was improved since the concrete reinforced with steel fiber restrained cracking. In addition, the fact that the cross-sections of the concrete were barely damaged indicates that load share capacity was greatly improved.
Keywords
Steel-fiber; Fire-Performance; Internally anchored square column; Mixing ratio; Thermal stress;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Kodur, V.K.R. and Mackinnon, D.H. (2000) Design of Concrete Filled Hollow Structural Steel Column for Fire Endurance, Engineering Journal-AISC Vol.37, No.1, pp.13-24.
2 Kodur, V.K.R. and Wang, T.C. (2004) Stress-Strain Curve for High Strength Concrete at Elevated Temperature, Journal of materials in Civil Engineering, Vol.16, No.1, pp.84-94.   DOI   ScienceOn
3 AISC (2005, 2010) Steel Construction Manual, American Institute of Steel Construction Ins.
4 ACI Committee 544 (1988) Design Consideration for Steel Fiber Reinforced Concrete : Workability, Behavior under Long-Term Loading, and Air-Void Characteristics, ACI, Vol.85, No.3, pp.189-196.
5 DIN-Normen Ausschuss (1998) Beton und Stahlbetos, Bemussung und Ausfuhrung-DIN 1045.
6 이성희, 김선희, 김영호, 최성모 (2009) 조립각형 CFT 기둥의 용접크기 결정을 위한 수압실험 및 해석, 한국강구조학회논문집, 한국강구조학회, 제 21권, 제5호, pp.515-526.(Lee, S.H., Kim, S.H., Kim, Y.H., and Choi, S.M. (2009) Water pressure Test and analysis for Welding Thickness Decision for New Cold-formed Type Concrete Filled Tubular Square Column, Journal of Korean Society of Steel Construction, KSSC, Vol.21, No.5, pp.515-526 (in Korean).)   과학기술학회마을
7 구철회, 이철호, 안재권(2013) 화재 시 무피복 CFT 기둥의 축강도 평가를 위한 단면온도분포 예측기법의 개발, 한국강구조학회논문집, 한국강구조학회, 제25권, 제6호, pp. 587-599.(Koo, C.H., Lee, C.H., and Ahn, J.K. (2013) Prediction of Temperature Distribution to Evaluate Axial Strength of Unprotected Concrete-filled Steel Tubular Columns under Fire, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.6, pp.587-599 (in Korean).)   과학기술학회마을   DOI
8 김해수, 이치형(2010) 내화피복종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구, 한국강구조학회논문집, 한국강구조학회, 제22권, 제6호, pp.523-532.(Kim, H.S. and Lee, C.H. (2010) An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection, Journal of Korean Society of Steel Construction, KSSC, Vol.22, No.6, pp.523-532 (in Korean).)
9 Kodur, V.K.R. and Lie, T.T. (1997) Evaluation of fire Resistance of Rectangular Steel Columns Filled with Fiber-Reinforced Concrete, Canadian Journal of Civil Engineering, Vol.24, pp.339-349.   DOI   ScienceOn
10 Kodur, V.K.R. and Lie, T.T. (1996b) Fire Resistance of Circular Steel Ccolumns Filled with Fiber Reinforced Concrete, Journal of Structural Engineering, Vol.122, pp.776-782.   DOI   ScienceOn
11 Kodur, V.K.R. (1998) Design Equations Evaluating fire Resistance of SFRC-filled HSS Columns, Journal of Structural Engineering, Vol.124, pp.671-677.   DOI   ScienceOn
12 Kodur, V.K.R. (1999) Perforce Based Fire Resistance Design of Concrete Filled Steel Columns, Journal of Constructional Steel Research, Vol.51, pp.21-36.   DOI   ScienceOn
13 ASTM C 1018-84 (1984) Standard Test Method for Flexural Toughness and First - Crack Strength of Fiber - Reinforced Concrete (using Beam with Third Point Loading), ASTM C 1018-84, pp.656-661.
14 김선희, 염경수, 최성모(2013) 내부 앵커형 콘크리트 충전기둥의 내력 및 변형 능력에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제25권, 제4호, pp.347-357.(Kim, S.H., Yom, K.S., and Choi, S.M. (2013) A Study on the Load Carrying Capacity and Deformation capacity of the Internal Anchors Welded Cold Formed Concrete Filled Columns, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.4, pp.347-357 (in Korean).)
15 이성희, 정헌모, 김대중, 김진호, 최성모(2008) 용접조립각형 CFT기둥-보 외다이아프램 접합부의 구조특성, 한국강구조학회논문집, 한국강구조학회, 제20권, 제6호, pp.711-722.(Lee, S.H., Jung, H.M., Kim, D.J., Kim, J.H., and Choi, S.M. (2008) Structural Characteristics of Welded Built-up Square CFT Column to Beam Connections with External, Journal of Korean Society of Steel Construction, KSSC, Vol.20, No.6, pp.711-722 (in Korean).)
16 이성희, 최영환, 염경수, 김진호, 최성모(2008) 용접조립각형 CFT단주의 구조특성에 관한 실험적 연구, 한국강구조학회논문집, 한국강구조학회, 제20권, 제5호, pp.645-653.(Lee, S.H., Choi, Y.H., Yom, K.S., Kim, J.H., and Choi, S.M. (2008) An Experimental Study on Structural Performance of Welded Built-up Square stub Columns, Journal of Korean Society of Steel Construction, KSSC, Vol.20, No.5, pp.645-653 (in Korean).)
17 김선희, 원용안, 최성모(2012) 비재하 가열실험을 통한 이중강관 CFT기둥의 잔존강도 평가연구, 한국강구조학회논문집, 한국강구조학회, 제24권, 제1호, pp.81-89.(Kim, S.H., Won, Y.A., and Choi, S.M. (2012) A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.1, pp.81-89 (in Korean).)   과학기술학회마을   DOI   ScienceOn