• 제목/요약/키워드: Square Cross Sectional

검색결과 292건 처리시간 0.025초

한면에 리브가 설치된 4면 수축 사각채널에서 리브의 각도가 열전달에 미치는 영향 (Effects of Rib Angles on Heat Transfer in a Square Convergent Channel with Ribs on One Wall)

  • 이명성;김범수;안수환
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.69-74
    • /
    • 2016
  • The local heat transfer and pressure drops of developed turbulent flows in the convergent channels with square cross-sectional areas along the streamwise distance have been investigated experimentally. Four different parallel angled ribs (a = $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$) are placed to the one sided wall only, respectively. The ribbed walls are manufactured with a fixed rib height (e)=10 mm and the ratio of rib spacing (p) to height (e) = 10. The measurement was run within the range of Reynolds numbers from 22,000 to 79,000. The result shows that the increases in the Nusselt numbers for the flow attack angles can be seen in the order of $30^{\circ}$, $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$.

Thermal-Hydraulic Aspects of an Advanced Reactor Core with Triangular Lattice Fuel Assemblies

  • Hwang, Dae-Hyun;Yoo, Yeon-Jong;Kim, Young-Jin;Chang, Moon-Hee
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.379-384
    • /
    • 1996
  • Thermal-hydraulic performance has been analyzed for an advanced reactor core loaded with hexagonal fuel assemblies. Currently available CHF prediction models and data base for triangular lattice bundles have been thoroughly reviewed, and as a result the KfK-3 CHF correlation with limit CHFR of 1.235 has been determined to be most appropriate. The pressure drop model in COBRA-IV-I code has been modified for the analysis of triangular lattice rod bundles. In view of maximizing the thermal margin, the geometry of a hexagonal fuel assembly, such as rod diameter and rod pitch, has been optimized with a fixed fuel assembly cross sectional area The optimum value of the moderator-to-fuel volume ratio is estimated to lie between 0.65 to 1 with 9.5 mm rod diameter. The thermal margin of these hexagonal fuel assemblies in the AP600 core has been evaluated and compared with that of square lattice fuel assemblies such as VANTAGE-5H and KOFA. The analysis result shows that the performances of hexagonal fuel assemblies are more favorable than the square fuel assemblies in the aspect of steady-state overpower margin.

  • PDF

Basal Area-Stump Diameter Models for Tectona grandis Linn. F. Stands in Omo Forest Reserve, Nigeria

  • Chukwu, Onyekachi;Osho, Johnson S.A.
    • Journal of Forest and Environmental Science
    • /
    • 제34권2호
    • /
    • pp.119-125
    • /
    • 2018
  • The tropical forests in developing countries are faced with the problem of illegal exploitation of trees. However, dearth of empirical means of expressing the dimensions, structure, quality and quantity of a removed tree has imped conviction of offenders. This study aimed at developing a model that can effectively estimate individual tree basal area (BA) from stump diameter (Ds) for Tectona grandis stands in Omo Forest Reserve, Nigeria, for timber valuation in case of illegal felling. Thirty-six $25m{\times}25m$ temporary sample plots (TSPs) were laid randomly in six age strata; 26, 23, 22, 16, 14, and 12 years specifically. BA, Ds and diameter at breast height were measured in all living T. grandis trees within the 36 TSPs. Least square method was used to convert the counted stumps into harvested stem cross-sectional areas. Six basal area models were fitted and evaluated. The BA-Ds relationship was best described by power model which gave least values of Root mean square error (0.0048), prediction error sum of squares (0.0325) and Akaike information criterion (-15391) with a high adjusted coefficient of determination (0.921). This study revealed that basal area estimation was realistic even when the only information available was stump diameter. The power model was validated using independent data obtained from additional plots and was found to be appropriate for estimating the basal area of Tectona grandis stands in Omo Forest Reserve, Nigeria.

Workplace Smoking Ban Policy and Smoking Behavior

  • Kim, Beom-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • 제42권5호
    • /
    • pp.293-297
    • /
    • 2009
  • Objectives : To evaluate the impact of the workplace smoking ban in South Korea, where the male smoking rate is high (57%), on smoking behavior and secondhand smoke exposure. Methods : A workplace smoking ban legislation implemented in April 2003 requires offices, meeting rooms, and lobbies located in larger than 3,000 square meter buildings (or 2,000 square meter multipurpose buildings) should be smoke free. A representative cross-sectional survey, the third wave (2005) of health supplements in the National Health Nutrition Survey of South Korea, was used to measure the impact of the 2003 workplace smoking ban implementation on smoking behavior. It contained 3,122 observations of adults 20 to 65 years old (excluding selfemployed and non-working populations). A multivariate statistical model was used. The self-reported workplace smoking ban policy (full workplace ban, partial workplace ban, and no workplace ban) was used as the key measure. Results : A full workplace smoking ban reduced the current smoking rate by 6.4 percentage points among all workers and also decreased the average daily consumption among smokers by 3.7 cigarettes relative to no smoking ban. Secondhand smoke showed a dramatic decrease of 86 percent (= -1.74/2.03)from the sample mean for full workplace ban. However, public anti-smoking campaign did not show any significant impact on smoking behavior. Conclusions : The full workplace ban policy is effective in South Korea. Male group showed bigger impact of smoking ban policy than female group. The public antismoking campaign did not show any effectiveness.

AL 박육부재의 에너지 흡수 제어특성 (Energy Absorbing Control Characteristic of Al Thin-walled Tubes)

  • 양용준;양인영
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.86-91
    • /
    • 2008
  • The structural members must be designed to control characteristics of energy absorption for protecting passengers in a car accident. Study on collapse characteristics of structural member is currently conducted in parallel with other studies on effective energy absorption capacity of structural members with diverse cross-sectional shapes and various materials. This study concerns the crashworthiness of the widely used vehicle structural members, square thin-walled tubes, which are excellent in the point of the energy absorption capacity. The absorbed energy, mean collapse load and deformation mode were analyzed for side member which absorbs most of the collision energy. To predict and control the energy absorption, controller is designed in consideration of its influence on height, thickness and width ration in this study. The absorbed energy and mean collapse load of square tubes were increased by $15{\sim}20%$ in using the controller, and energy absorbing capability of the specimen was slightly changed by change of the high controller's height.

LDV에 의한 곡관 후류에 연결된 직관에서 난류맥동유동의 유동특성 (Flow Characteristics of a Turbulent Pulsating Flow in a Straight Duct Connected to a Curved Duct by using an LDV)

  • 손현철;이행남;박길문
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.177-186
    • /
    • 2003
  • In the present study, the flow characteristics of developing turbulent flows are investigated at the exit region of a square cross-sectional 180" curved duct with dimensions of 40mm$\times$40mm$\times$4000mm (height $\times$ width $\times$length). Smoke particles produced from mosquito coils were used as seed particles for the LDV measurement. Experiments were carried out to measure axial velocity profiles, shear stress distributions and entrance lengths by using an LDV system and Rotating Machinery Resolver RMR with PHASE software. Experimental results clearly show that the time-averaged Reynolds number does not affect oscillatory flow characteristics because the turbulent components tend to balance the oscillatory components in the fully developed flow region. Also, the velocity profiles are in good agreement with 1/7power law such as the results of steady turbulent flows. The turbulent intensity linearly increases along the walls and is slightly higher, especially in the period of deceleration. On the other hand, the LDV measurements show that shear stress values in slightly higher in the period of deceleration due to the flow characteristics in the exit region. The entrance length where flows become stable appears at the point that is 40 times the length of hydraulic diameter.eter.

중국 건강불평등 현상에 대한 고찰 (Investigation on the Health Inequality in China)

  • 미설;임재영
    • 국제지역연구
    • /
    • 제20권2호
    • /
    • pp.175-194
    • /
    • 2016
  • 본 연구는 사회경제적 요인이 중국인의 건강상태에 미치는 영향을 통해 건강불평등 현상의 존재 여부를 고찰하는데 그 목적이 있다. 이를 위하여 중국인의 건강 상태와 사회경제적 특성과 관련된 다양한 정보를 포함하고 있는 자료원인 중국 건강 영양 자료(China Health and Nutrition Survey)의 2000년, 2004년, 2009년 자료를 병합하여 얻은 자료를 바탕으로 Ordinary Least Square model (OLS) 모델과 Ordered Logit 모델을 이용해서 실증분석을 수행하였다. 본 연구에서 얻은 실증분석 결과를 소개하면, 사회경제적 특성을 나타내는 변수들이 중국인의 건강 수준을 나타내는 변수들에 미치는 영향을 분석한 결과, 이들 변수가 중국인의 건강 수준에 미치는 영향이 통계적으로 유의했던바, 이를 토대로 2000년 이래로 중국의 건강불평등 현상이 존재함을 확인하였다.

An enhanced simulated annealing algorithm for topology optimization of steel double-layer grid structures

  • Mostafa Mashayekhi;Hamzeh Ghasemi
    • Advances in Computational Design
    • /
    • 제9권2호
    • /
    • pp.115-136
    • /
    • 2024
  • Stochastic optimization methods have been extensively studied for structural optimization in recent decades. In this study, a novel algorithm named the CA-SA method, is proposed for topology optimization of steel double-layer grid structures. The CA-SA method is a hybridized algorithm combining the Simulated Annealing (SA) algorithm and the Cellular Automata (CA) method. In the CA-SA method, during the initial iterations of the SA algorithm, some of the preliminary designs obtained by SA are placed in the cells of the CA. In each successive iteration, a cell is randomly chosen from the CA. Then, the "local leader" (LL) is determined by selecting the best design from the chosen cell and its neighboring ones. This LL then serves as the leader for modifying the SA algorithm. To evaluate the performance of the proposed CA-SA algorithm, two square-on-square steel double-layer grid structures are considered, with discrete cross-sectional areas. These numerical examples demonstrate the superiority of the CA-SA method over SA, and other meta-heuristic algorithms reported in the literature in the topology optimization of large-scale skeletal structures.

일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가 (Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads)

  • 박수희;송경철;류재용;정경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.655-663
    • /
    • 2008
  • 본 연구에서는 콘크리트충전 원형강관(원형 CFT)기둥의 내화성능을 평가하기 위하여 수치해석을 수행하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 축력, 단면 직경을 변수로 설정하였다. 수치해석의 정확성을 검증하기 위하여, 기존의 각국 내화성능설계식들에 의한 계산 결과값과 비교 평가 하였다. 또한, 기존의 실대 원형 CFT기둥의 내화성능 평가 실험 결과와 함께 비교 분석하여 수치해석의 타당성을 검증하였다. 원형 CFT기둥의 내화실험 및 수치해석적 연구를 통해 도출된 내화저항시간과 축력비, 단면직경, 콘크리트 강도의 영향을 각형 CFT기둥의 내화성능과 비교 분석하여 각 영향인자들의 영향을 평가하였다. 본 연구의 수치해석적 연구는 실험결과와 비슷한 거동 및 내화성능을 보였다. 따라서 본 연구에서의 수치해석에 의한 CFT기둥의 내화 성능 예측은 타당하다고 판단된다.

소오스/드레인 영역의 도펀트 양의 증가에 따른 코발트실리사이드의 물성변화 (Influence of Dose on the Property of Cobalt Silicides in Source/Drain Area)

  • 정성희;송오성;김민성
    • 한국재료학회지
    • /
    • 제13권1호
    • /
    • pp.43-47
    • /
    • 2003
  • As and BF$_2$dopants are implanted for the formation of source/drain with dose of 1${\times}$10$^{15}$ ions/$\textrm{cm}^2$∼5${\times}$10$^{15}$ ions/$\textrm{cm}^2$ then formed cobalt disilicide with Co/Ti deposition and doubly rapid thermal annealing. Appropriate ion implantation and cobalt salicide process are employed to meet the sub-0.13 $\mu\textrm{m}$ CMOS devices. We investigated the process results of sheet resistance, dopant redistribution, and surface-interface microstructure with a four-point probe, a secondary ion mass spectroscope(SIMS), a scanning probe microscope (SPM), and a cross sectional transmission electron microscope(TEM), respectively. Sheet resistance increased to 8%∼12% as dose increased in $CoSi_2$$n^{+}$ and $CoSi_2$$p^{V}$ , while sheet resistance uniformity showed very little variation. SIMS depth profiling revealed that the diffusion of As and B was enhanced as dose increased in $CoSi_2$$n^{+}$ and $CoSi_2$$p^{+}$ . The surface roughness of root mean square(RMS) values measured by a SPM decreased as dose increased in $CoSi_2$$n^{+}$ , while little variation was observed in $CoSi_2$$p^{+}$ . Cross sectional TEM images showed that the spikes of 30 nm∼50 nm-depth were formed at the interfaces of $CoSi_2$$n^{+}$ / and $CoSi_2$/$p^{+}$, which indicate the possible leakage current source. Our result implied that Co/Ti cobalt salicide was compatible with high dose sub-0.13$\mu\textrm{m}$ process.