• Title/Summary/Keyword: Sprinkler Head

Search Result 59, Processing Time 0.02 seconds

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

A study on the thermal reponsivenes of automatic sprinklers (스프링클러 소화설비의 열감지에 관한 연구)

  • Son, Bong-Se
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.9-12
    • /
    • 1991
  • As the present idustry is devolping rapidly, automatic sprinklers continue to play a key role in modern fire protection. But the technical basis and methods of measurement of the thermal response of sprinklers are not studying in our country. Therefore, the purpose of this paper is to analyze the thermal response characteristics and condition parameters of automatic sprinkler head.

  • PDF

A Study about Introductory Plan of Automatic Wet Pipe Sprinkler System to Hydraulically Designed System (습식 스프링클러설비의 수리계산방식 도입방안에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2007
  • Our country automatic wet pipe sprinkler system of hydraulically designed system has not deviated from the pipe regulation process, therefore we face limitations when using an independent method to hydraulically designed system. Therefore. after reviewing a developed country's methods using the drainage-density concept, we found it necessary for our country to introduce the drainage-density concept. Currently, under the National Fire Safety Codes(NFSC), this does not solve the problem and the limitation of hydraulically designed system because different problems arise depending on where the head was installed. To make improvements, first, such as the developed country, overcome the difference by introducing the drainage-density concept to determine the amount of drainage. Second, by using diverse head caliber and decreasing the limits on the amounts of distribution, we can expect a leveling off of the drainage density. Third, using the increase of hydraulically designed system through the application of the rule to hydraulically designed system, finally, development to performance based fire protection design.

Development of Independent Sprinkler for Fire Safety (소방안전을 위한 독립 스프링클러 개발)

  • Yun, Hae-Yong;Kim, Seon-Yeop;Kim, Ho-Chan;Park, In-Beck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

A Study on the Corrosion According to Post-Forming Treatment of a Horizontal Side Wall Sprinkler Head Deflector (측벽형 스프링클러 헤드 디플렉터의 성헝후처리에 따른 부식특성에 관한 연구)

  • 민인홍;전동일;김형종;박종연
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.77-83
    • /
    • 2002
  • The objective of this study is to propose a method to prevent the possible stress corrosion cracking of a horizontal side-wall sprinkler head deflector in the same atmosphere of ammonia gas as it regulated in the UL (Underwriters Laboratory). A corrosion test is carried out for three types of specimen according to post-forming treatment, one of which is annealing, another sand blasting and the other no treatment. The observation of the test specimens with a metal micro-scope says that the tensile residual stress is a major factor causing corrosion cracking, and that a proper heat treatment can remove or reduce the residial stress and prevent a crack from occurring even in a severe corrosive atmosphers.

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.

An Experimental Study of Flow Behaviour in Underground Stairway Fire (지하계단 화재에서 유동에 대한 실험연구)

  • 정진용;홍기배;이재하;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.821-827
    • /
    • 2003
  • Reduced-scale experimental study was carried out on the heat flow behavior which flows under the sloped ceiling in underground fire. Temperature and flow velocity were measured to characterize the ceiling jet along the sloped stairway ceiling. The methanol fuel was used as a model fire source giving 2.2 and 3.4 kW, with changing the slope angle of stairway adopting of 15, 25, 35, and 45 deg. Based on the experimental data, excess temperature and velocity along the sloped stairway ceiling were examined which are usefully applicable to estimate the activating conditions of heat detector and sprinkler head mounted on the sloped ceiling. Excess temperature in upper exit of the sloped stairway was also examined to analyze the soffit which delays the smoke diffusion. The result shows that the activating conditions of heat detector and sprinkler in the sloped stairway ceiling have to be considered differently in a point of about 30 deg.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.37-41
    • /
    • 1997
  • 스프링클러 소화설비는 화재가 발생하였을 때 자동적으로 감열, 작동하여 초기화재 진압을 목적으로 하는 소화설비로서 소화특성은 화재발생으로부터 소화가 시작되는 화재감지특성과 화재제어 및 진압에 대한 방사특성1) 으로 FRS2) 3)와 FMRC4)에서는 열응답의 민감도를 나타내는 반응시간지수(RTI)의 측정방법과 이론을 제시하였다. 반응시간지수는 스프링클러헤드의 작동에 필요한 충분한 열을 주위로부터 얼마나 빠른 시간내에 흡수 할 수 있는지를 나타내는 특성치로서 가열공기의 온도 및 속도에 의해 결정되며 값이 적을수록 헤드가 조기에 작동하게 된다. (중략)

  • PDF