• Title/Summary/Keyword: Sprinkler

Search Result 282, Processing Time 0.027 seconds

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.

Analysis of Irrigation Amounts and Soil Volumetric Water Contents by Irrigation Method in Saemangeum Reclaimed Tideland (새만금 간척지 밭 토양의 관개 방식별 관개용수량과 토양 용적수분함량 변화 분석 연구)

  • Son, Jae-Gwon;Yoon, Sang-Won;Song, Jae-Do
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.73-80
    • /
    • 2023
  • This study was conducted to analyze changes of irrigation water and soil volumetric water content by irrigation method of field soil in Saemangeum reclaimed tideland. The main test irrigation methods was surface drip irrigation, sprinkler irrigation, and sub drip irrigation. In addition, the correlation between irrigation amounts and crop yield by irrigation method was investigated. For soil volumetric water contents increases by 25%, surface drip irrigation took 1.5 hour, sprinkler irrigation took 2.0 hours, and sub drip irrigation took 3.0 hours. As a result of analyzing the irrigation amounts according to the yield, the surface drip irrigation was 2.66 mm/day in the seedling stages, 3.31 mm/day in the vegetative growth stages, and 5.09 mm/day in the flowering stages. Sprinkler irrigation was 2.90 mm/day in the seedling stages, 3.87 mm/day in the vegetative growth stages, and 7.11 mm/day in the flowering stages. Sub drip irrigation was 2.42 mm/day in the seedling stages, 3.09 mm/day in the vegetative growth stages, and 4.87 mm/day in the flowering stages. It was analyzed that there was a statistically significant difference in irrigation amounts by fresh weight and irrigation method (F=4.002, p=0.022), and irrigation amounts by dry weight and irrigation method (F=3.499 p=0.034). Surface drip irrigation was judged to be more appropriate than sprinkler irrigation or sub drip irrigation for field crops in Saemangeum reclaimed land.

A Study on Safety by Risk Assessment of Clean Room (Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구)

  • Song Yun-Suk;Yoon Myong-O;Hyun Seong-Ho;Lee Chang-Woo;Yoon Yo-Song;Kim Sung-Min
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.78-85
    • /
    • 2004
  • This research analyzes Clean Room accidents, and presents research Clean Room, major fire prevention standards of Clean Room (FM, IRI, and NFPA Code), various results from Fire Simulation of analysis. The results are : the smoke diffusion is very quick coupled with the Heating, Ventilating, and Air Conditioning (HVAC) systems under fire ; the possibility of getting the result and the possibility the role of the Sprinkler systems to reduce the diffusion of the smoke. We learn about the importance to stop operating Heating, Ventilating, and Air Conditioning (HVAC) systems and to operate the Sprinkler system for securing safety with fire detection. Therefore, This research will be contributing to secure safety of Clean Room.

Directional Water Spray Characteristics of Sprinkler Heads (스프링클러 헤드의 방향성 살수 특성 비교 연구)

  • Park Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.35-41
    • /
    • 2004
  • The water spray characteristics of the sprinkler heads is a very important factor affecting the fire suppression performance, and it is largely dependent on the shape of the head nozzle. This study investigated shape factors and spray distribution performances for the sprinkler heads of four domestic companies with big market shares. The experimental results revealed that all flow constants exceeded the required regulation limits, however showed big differences between head types although they have the same design limit. They were however relatively consistent regardless of the pressure increases. The spray distribution of some head samples showed severe directional eccentricity, which suggests more study for the improvement.

Development of Independent Sprinkler for Fire Safety (소방안전을 위한 독립 스프링클러 개발)

  • Yun, Hae-Yong;Kim, Seon-Yeop;Kim, Ho-Chan;Park, In-Beck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

Use of Hydrazine for Pitting Corrosion Inhibition of Copper Sprinkler Tubes: Reaction of Hydrazine with Corrosion By-Products

  • Suh, Sang Hee;Kim, Sohee;Suh, Youngjoon
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.247-256
    • /
    • 2017
  • The feasibility of using hydrazine for inhibiting pitting corrosion in copper sprinkler tubes was investigated by examining microscopical and structural evolution of corrosion by-products with SEM, EDS, and XRD. Hydrazine removed dissolved oxygen and reduced CuO and $Cu_2O$ as well. The stable phase was changed from CuO to $Cu_2O$ or Cu depending on hydrazine concentration. Hydrazine concentration of 500 ppm could convert all CuO corrosion by-products to $Cu_2O$. In a tightly sealed acryl tube filled with aqueous solution of 500 ppm hydrazine, octahedral $Cu_2O$ particles were formed while plate-like structures with high concentration of Cu, O, N and C were formed near a corrosion pit. The inside structure of a corrosion pit was not altered by hydrazine aqueous solution. Uniform corrosion of copper was almost completely stopped in aqueous solution of 500 ppm hydrazine. Corrosion potential of a copper plate was linearly dependent on log (hydrazine concentration). The concept of stopping pitting corrosion reaction by suppressing oxygen reduction reaction could be verified by applying this method to a reasonable number of real sprinkler systems before full-scale application.

Evaluation of Seismic Performance of 2-Story Fire Protection Sprinkler Piping System (화재방호계통 복층구조 스프링클러 파이프라인 내진성능 평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.458-464
    • /
    • 2014
  • Fire protection (sprinkler) piping system is an essential element for the energy supply and for the protection against the seismic-induced fire during and after an earthquake. The primary objective of this study was to understand the seismic performance of complex two-story piping system installed in a low-rise building subjected to bi-directional and three-directional earthquakes. The result of current study revealed that the displacement of the piping system in accordance with floor level was significantly different due to acceleration-sensitivity but the effect of the piping system due to the vertical direction earthquake was not significant.

Development of glass bulb for sprinkler head system (스프링클러용 유리발브의 개발)

  • Kim, Byung-Cheol;Joung, Hoon-Choul;Seo, Yo-Won;Myung, Young-Sup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.144-147
    • /
    • 2008
  • A glass bulb is the most reliable and simplest device for a fire sprinkler head system. We had developed an accurate glass bulb. The glass bulb is composed with a glass ampoule, liquid filled within the ampoule and an air bubble in the liquid. The first step of the development was to establish a stable mass production system for uniform glass ampoule. The second step is to optimize the composition of the liquid and the size of the bubble. It was also a difficult problem to devise manufacturing process to form uniform bubble size. The final step for the development is to control the mechanics for glass breaking by surface treatment for the glass bulb.

  • PDF

Numerical Study of the Factors Affecting Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재풍속에 영향을 미치는 인자들에 관한 수치해석적 연구)

  • Kim, Byeongjun;Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2016
  • When an interior fire occurs in an apartment building, pollution of the entrance area by fire smoke before an air fan operates makes the evacuation of people very difficult aswhen the fire doors are opened. Numerical simulations using Fire Dynamics Simulator were conducted to determine the impact of a sprinkler on the fire flow velocity. The fire flow velocity was compared depending on the presence of sprinklers and the sprayed droplet size. The configuration and actual dimensions of an apartment building were used in the numerical simulations. The simulation results showed that fire flow velocity becomes smaller when a sprinkler is installed. In addition, the smaller droplet size results in a smaller fire flow velocity because smaller droplets can be evaporated more easily.

A Brief Study on Smoke Suppression Effects by Sprinkler Spray System (스프링클러설비에 의한 연기제어효과 고찰)

  • Cha, Jong-Ho;Yoon, Myung-O;Choi, Chun-Bae;Lee, Sun-Kyung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.560-565
    • /
    • 2006
  • Sprinkler system is the most effective fire suppression with high confidence among active fire extinguishing systems. According to the installation of the related system on buildings, more separation area of fire protection can be considered to the fire protection design, and also lower differential pressure (12.5 Pascal) is permitted on lobby of fire escape stairs and emergency elevator (25 Pascal shall be considered for none sprinkler system) with economic factor. More details will be handled on the related studies.

  • PDF