• 제목/요약/키워드: Spring-go

검색결과 69건 처리시간 0.026초

A Light-Weight Spring-Driven and Hydraulically-Damped Multiple Piston Corer

  • Lee, Tae-Hee;Go, Sung-Jun;Huh, Sung-Hoi;Lee, Tong-Sup
    • Journal of the korean society of oceanography
    • /
    • 제34권3호
    • /
    • pp.179-183
    • /
    • 1999
  • A light-weight multiple piston corer to meet increasing coring needs in areas where R/V access is limited, is designed and discussed. Hydraulically-damped and spring-driven piston system not only virtually undisturbed surface sediments but also facilitate the recovery and subsequent operation including pore water extraction and core slicing on board the ship. It is designed as compact, light-weight and easy to dissemble that whole gear can be carried by small passenger vehicle yet it permits thick-walled core tube for thermal insulation or large opening core tubes. Because single spring instead of heavy weights of conventional gravity-driven multiple corers is used, this device is very simple and cheap to construct.

  • PDF

천연 탄산 온천수의 아토피 유발 쥐 모델에 대한 혈소판 응집 억제 효능 평가 (The anti-coagulation effect of natural carbonated hot spring water on DNCB-induced NC/Nga mice.)

  • 장순우;박정환;곽진영;고영미;안택원
    • 혜화의학회지
    • /
    • 제26권1호
    • /
    • pp.19-24
    • /
    • 2017
  • Objectives:Spring water is widely known to relax muscles by promoting blood circulation. This study was conducted to analyze theantithrombotic effect of naturally carbonated hot spring water (NCHW) to assess its influence on blood circulation. Methods:Atopic dermatitis was induced in the skin of the mice used in this experiment. NCHW was applied, and the antithrombotic effect was assessed and compared with that of other interventions. The positive control group was treated orally with aspirin. Results:After 3 weeks of exposure to NCHW, the experimental groupshowed a significant antithrombotic effect. NCHW also produced inhibitory responses to both collagen- and ADP-induced platelet aggregation, whereas the group given aspirin reacted only to collagen-induced platelet aggregation. Conclusions:The experiment demonstrated the intrinsic antithrombotic effects of NCHW compared with those of artificially carbonated water, tap water, and aspirin. This result suggests the possibility that NCHW can be used as a supportive and alternative treatment for vascular diseases.

  • PDF

Beamline Automation of RIKEN Structural Genomics Beamlines

  • Ida, Koh;Yamamoto, Masaki;Kumasaka, Takashi;Ueno, Go;Kanda, Hiroyuki;Miyano, Masashi;Ishikawa, Tetsuya
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.463-465
    • /
    • 2002
  • RIKEN Structural Genomics Beamlines have been constructed for the crystallographic analysis in the structural genomics research at synchrotron radiation facility SPring-8. Synchrotron radiation accelerates the crystallographic analysis of protein structure. The target of the research and development is focused on the automatic beamline operation to maximize beamline efficiency. We are developing the sample management system, which is composed of the sample auto-changer and the database system, for high-throughput data collection. The sample management system and the beamline operating system make it possible to execute automatic data collection without any operators. The beamlines will be ready for user operation in autumn 2002. The concept of automatic beamline operation and the present status of RIKEN Structural Genomics Beamlines will be presented.

  • PDF

노년기 여성의 의복 디자인 선호도 및 의복 만족도에 대한 연구 (A Study of Clothing Design Preference & Clothing Satisfaction for Older Women)

  • 서미아;이선희
    • 복식문화연구
    • /
    • 제3권1호
    • /
    • pp.41-64
    • /
    • 1995
  • A clothing design preference & clothing satisfactions(a general satisfaction, fitness) was studied for women 55 years and older. The major results are as followings. In view of a clothing design preference, 1) Styles of outdoor clothes for spring-fall : ① Two-pieces ② Blouse(Sweater) & Slacks ③Blouse(Sweater) & Skirts. 2) Colors of clothes for seasons: (Spring - Pink, Light yellow, beige), (Summer - Light blue, Blue, Light green), (Fall - Brown, Red purple, Beige), (Winter - Black, Brown, Gray). 3) Fabric prints ; ① Unicolor without print ② Geometric print ③ Traditional print. 4) Kinds of textiles : ① Easy Laundriability ② A style of dressing ③ Uncrumple. In view of clothing satisfactions for ready made clothes, they have unsatisfactory trends as following orders. 1) Considering a general satisfaction : ① Clothing which go with oneself ② Fitness ③ Matching with other clothes. 2) Considering fitness for clothes : ① Sleve length ② Shoulder width ③ Length in Blouse (Sweater) & Jacket, ① Length ② Waist ③ Girth of hip (under abdomen) in slacks (skirts).

  • PDF

3D 스캐너를 이용한 커브드 모니터의 스프링백 분석 연구 (A study on the springback analysis of a curve monitor using a 3D scanner)

  • 윤형우;이춘규
    • Design & Manufacturing
    • /
    • 제12권3호
    • /
    • pp.13-18
    • /
    • 2018
  • Flexible display tends to grow every year, It tends to be larger, slimmer, and higher in image quality. Therefore, accuracy is required in the manufacturing process of each part. In the curved monitor, the bottom chassis has a structure to which other parts can be attached. The accuracy of the curvature which the bottom chassis of the curve monitor monitors has is important. If the curvature error is large, serious defects such as cracks, warpage, twisting and the like occur. Curvature was analyzed using 3D scanner. In the Forming process and Restriking process steps, spring go occurred, and spring back occurred in the Notching process and Bending process steps. Even in the same process, it was confirmed that the curvature value varied depending on the formed shape.

계면 Dzyaloshinskii-Moriya 상호작용과 궤도 자기 모멘트의 상관관계 연구

  • Kim, Sanghoon;Ueda, Kohei;Yamada, Kihiro;Suzuki, Motohiro;Kotani, Yoshinori;Nakamura, Tetsuya;Go, Gyungchoon;Jang, Peong-Hwa;Lee, Kyung-Jin;Belabbes, Abderrezak;Manchon, Aurelien;Nakamura, Kohji;Koyama, Tomohiro;Chiba, Daichi;Moriyama, Takahiro;Kim, Kab-Jin;Ono, Teruo
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2016년도 임시총회 및 하계학술연구발표회
    • /
    • pp.167-168
    • /
    • 2016
  • PDF

DNCB로 아토피가 유도된 NC/Nga생쥐에서 천연 탄산 온천수의 온도별 항아토피 효과 (The anti-atopic effect of natural carbonated hot spring water on DNCB-induced NC/Nga mice under different temperature)

  • 고가연;박정환;장순우;김윤하;박정미;안택원
    • 혜화의학회지
    • /
    • 제25권1호
    • /
    • pp.119-132
    • /
    • 2016
  • Objectives : The aim of this study is to investigate the effect of natural carbonated hot spring water (NCHW) on DNCB-induced NC/Nga mice, an atopic dermatitis (AD) model. Methods :At first, NC/Nga mice were prepared and induced to have atopic lesion on their back skin by dinitrochlorobenzene (DNCB). They swam for 20 minutes everyday in tanks where the one is filled with $28^{\circ}C$ NCHW, the other is with $25^{\circ}C$ carbonated hot spring water and another is with artificial carbonated hot spring water (ACHW). After 3 weeks, We assessed the skin clinical score and macroscopic appearance, total IgE, IgG1 levels, WBC differential counting, IFN-${\gamma}$, IL-4, IL-13, TNF-${\alpha}$ production levels and histological changes. Results : There are meaningful results of improving atopic lesion-state by relieving the count of total IgE, IgG1 levels, WBC differential counting, IFN-${\gamma}$, IL-4, IL-13, TNF-${\alpha}$ production levels and recovering skin clinical score in the group with $28^{\circ}C$ NCHW in comparison with the other groups. Conclusions : The NCHW may have potential as an effective treatment for atopic dermatitis.

리니어 모터구동 진공펌프 설계 및 해석 (The Design and Analysis of vacuum Pump Driven by Linear Motor)

  • 김동수;안영희;이원희;김광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.680-683
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of vacuum pump driven by linear motor. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve when spring farce (14.8N) is exerted. The results of simulation. it was turned out that reached vacuum pressure was about -0.55 bar at 150 seconds, magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF

야드형 AGV-서스펜션 파라미터의 최적화를 위한 충격하중 해석 (Analysis of Impact Load for Optimum of Suspension Parameter of Yard AGV)

  • 홍도관;김재헌;안찬우;전언찬;김중완
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2002년도 추계공동학술대회논문집
    • /
    • pp.161-167
    • /
    • 2002
  • Cai-go management facility of harbor are required an expansion due to increase of cargo quantity. Design technology of Yard AGV call be possible to deal many cargo rapidly and accurately. So it is produced a profit about cal-go management. This study is presented optimum of suspension parameter for design technology Yard AGV. Model I, II are modeled about Initial of container weight, height. When the maximum stroke of suspension is 0.26m, optimum is achieved to reduce the reaction force at the minimum. Also, the reaction force is study to become stability in I second. A change of spring constant and coefficient of damper make change the reaction force and minimum reaction force appear in optimum value. All modeling and analysis are used combination. contact element of Ansys program.

  • PDF

의료용 펌프의 리니어 모터 설계 및 해석 (Design and Analysis of Linear Motor for Medical Appliance Pump)

  • 김동수;이원희;박재범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2683-2686
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of linear motor for medical appliances. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve, when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve, when spring force (14.8N) is exerted. The results of simulation, it was turned out that magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF