• Title/Summary/Keyword: Spot measurement

Search Result 234, Processing Time 0.024 seconds

Simple Bluetooth Wireless Multi-gas Measurement System (간단한 블루투스 무선다중가스센서 계측시스템)

  • Kim, Chul min;Kim, Doyoon;Kim, Yeonsu;Kim, Gyu-tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.51-54
    • /
    • 2020
  • To develop gas-distinguishing sensor system, it is highly required to integrate multiple sensors for effective detection of a single targeted gas or mixture of gases. In addition, it is important to collect the reliable data from individual sensors into one integrated measuring device. Collecting the data of toxic gases on the spot should be done without inhalation. We suggest simple wirelessly running system for data collection that guarantees both reliability of data sources and safety. Here, we made a multi-gas measuring instrument(device) combined with Bluetooth module which provides a safe and precise big data accumulation system.

The ablation of ITO thin films by KrF Eximer laser and its characteristics (KrF 엑시머 레이저에 의한 ITO 박막의 어블레이션과 표면특성관찰)

  • Lee, Kyoung-Cheol;Lee, Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.511-514
    • /
    • 2000
  • This work aimed to develop ITO (Indium Tin Oxide) thin films ablation with a KrF Eximer laser required for the application in flat panel display, especially patterning into small geometry on a large substrate area. The threshold fluence for ablating ITO on glass substrate is about 0.1 J/cm$^2$. And its value is much smaller than using third harmonic Nd:YAG laser. Through the optical microscope measurement the surface color of the damaged ITO is changed into dark brown and irradiated spot is completely isolated form the undamaged surroundings by laser light. The XPS analysis showed that the relative surface concentration of Sn and In were essentially unchanged (In :Sn=5:1) after irradiating Eximer laser. Using aluminium mask made by second harmonic Nd:YAG laser the ITO patterning is carried out.

  • PDF

Plasma spectroscopy aimed at quantifying the flame equivalence ratio (화염의 정성적 당량비 측정을 위한 Plasma Diagnostics에 관한 연구)

  • Lee, SeokHwan;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.99-101
    • /
    • 2013
  • The equivalence ratio is measured by LIBS(Laser-induced Breakdown spectroscopy) in hydrocarbon flame and high temperature (${\sim}3200^{\circ}C$) oxyhydrogen flame, where a stoichiometric mixture of hydrogen and oxygen is produced from water through electrolysis. The ratio of the hydrogen and oxygen (H/O) atomic lines intensities is used for quantitatively determining the quivalence ratio. laser energy is evaluated for determining the optimal condition for plasma diagnostics. The minimum laser energy for generating plasma in a laminar premixed hydrocarbon flame was about 70 mJ, whereas oxyhydrogen flame. consequently the irradiated spot of a lower density in high temperature oxyhydrogen flame gave rise to bigger plasma in size, thus limiting the spatial resolution of the LIBS measurement.

  • PDF

A Study of Voice signal Capture for communication in the AFV (기동무기체계에서의 통신을 위한 음성신호 포착 연구)

  • 김석봉;이성태
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.81-90
    • /
    • 2003
  • In the military communication environment, it is very difficult to obtain clear voice signal due to the high level noise. The purpose of this study is to find out the best body spot to get the vocal chords signal by measuring the skin or the bone conducting vibrations of different body positions within the noise environment. Based on the experimental study, it was found out that the measurement of sound signal within the ear is the best way to get the voice which comes from the vocal chords and this method can prevent the interruption of noise. This study will give the effective voice communication method in the high noise environment and be applicable to military purpose.

Precise Measurement of the change n the optical length of a fiber Fabry-Perot interferometer. (광섬유 Fabry-Perot 간섭계를 이용한 위상 변화량의 정밀 측정)

  • 김영준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.113-118
    • /
    • 1989
  • By using the single mode optical fiber, we fabricated Fiber-optic Fabry-Perot interferometer (FFPI). The change over a wide range in the optical path length of a FFPI is observed. The temporal movement of the interference fringes by external condition to P.Z. T) is converted to circular motion on an oscilloscope display and then recorded with a micro-computer. The two output voltages of the D/A converters are applied to X and Y terminals of oscilloscope to display circular motion on oscilloscope. Thus the direction of phase shift can be determined with observing the direction of circular motion. The variation of the optical length can be measured by calculating the angle of spot of circle with an accuracy of λ/90 wave length due to variation of temperature in this system 2.7x10-4$^{\circ}C$.

  • PDF

A Theoretical and Empirical Survey of Computer Attitudes

  • JUNG, Sei-Hwa
    • Educational Technology International
    • /
    • v.9 no.2
    • /
    • pp.57-77
    • /
    • 2008
  • For years, research on the impact of students' attitudes on learning has maintained a spot amongst the most highly discussed topics in education. Particularly, over the past decades, researchers have made great strides in better understanding attitudes toward computers. This article presents a critical review of the current state of research by re-examining how attitudes toward computers have been studied. First, the review introduces an overview of the theoretical foundations and the origins of research on attitudes toward computers. Then, the article summarizes previous literature and knowledge about computer attitudes and provides a review of major findings from research on the effects of some factors affecting the formation of computer attitudes. The discussion reveals a number of major issues and challenges, which include unclear characterization of computer attitudes, problems with measurement tools, and the lack of studies using methods other than brief questionnaires. The unsolved problems cause conflicting, inconsistent and inconclusive results and affect interpretation in the study of computer attitudes. The article also suggests the main recent and future directions of research on attitudes toward computers. Finally, it concludes by providing implications for educators.

Development of accuracy for the statical inclinometer by error analysis (다축 수준기의 오차분석을 통한 측정 정밀도 향상)

  • Lee J.K.;Park J.J.;Cho N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1797-1802
    • /
    • 2005
  • In this study, we were developed an accuracy of the proposed two dimensional statical inclinometer what used a position sensitive detector(PSD) by an error analysis. The inclinometer consists of a laser source, a mass, an optic-fiber, and a PSD. The gravity direction on a base platform of the inclinometer is changed by an unknown inclination angle. And a laser spot is moved from the origin to another position of a PSD following a variation of an optical path by the gravity. These processes enable the inclinometer to estimate the inclination angle from distance information of the moving spot. A design methodology on the basis of a sensitivity analysis was applied to improve the measurement performance such as a full measuring range and a resolution. But it still has error factors, so we analyze the uncertainty of the inclinometer to evaluate the systematic errors from alignments, assembly error and so on. The experimental performance evaluation about the design objectives as a measuring range and a resolution was performed. And the validity and the feasibility of the design process were certified by an experimental process. Systematic errors eliminated to improve the accuracy of the inclinometer by the corrected measuring model from the calibration process between the inclination angle and the PSD position instead of the nominal measuring model. The ANOVA(analysis of variance) confirmed the effect of eliminating the systematic errors in the inclinometer. From these methodologies, the proposed inclinometer was able to measure with a high resolution(35.14sec) and a wide range(from $-15^{\circ}\;to\;15^{\circ}$

  • PDF

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Analysis and Cut-off Adjustment of Dried Blood Spot 17alpha-hydroxyprogesterone Concentration by Birth Weight (신생아의 출생 체중에 따른 혈액 여과지 17alpha-hydroxyprogesterone의 농도 분석 및 판정 기준 조정)

  • Park, Seungman;Kwon, Aerin;Yang, Songhyeon;Park, Euna;Choi, Jaehwang;Hwang, Mijung;Nam, Hyeongyeong;Lee, Eunhee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.14 no.2
    • /
    • pp.150-155
    • /
    • 2014
  • The measurement of $17{\alpha}$-hydroxyprogesterone ($17{\alpha}$-OHP) in a dried blood spot on filter paper is an important for screening of congenital adrenal hyperplasia (CAH). Since high levels of $17{\alpha}$-OHP are frequently observed in premature infants without congenital adrenal hyperplasia, we evaluated cuts-off based on birth weight and performed validation. Birth weight and $17{\alpha}$-OHP concentration data of 292,204 newborn screening subjects in Greencross labopratories were analyzed. The cut-off values based on birth weight were newly evaluated and validated with the original data. The mean $17{\alpha}$-OHP concentration were 7.25 ng/mL in very low birth weight (VLBW) group, 4.02 ng/mL in low birth weight (LBW) group, 2.53 g/mL in normal birth weight (NBW) group, and 2.24 ng/mL in heavy birth weight (HBW) group. The cut-offs for CAH were decided as follows: 21.12 ng/mL for VLBW and LBW groups and 11.14 ng/mL for NBW and HBW groups. When applied new cut-offs for original data, positive rates in VLBW and LBW groups were decreased and positive rates in NBW and HBW groups were increased. The cut-offs based on birth weight should be used in the screening for CAH. We believe that our new cut-off reduce the false positive rate and false negative rate and our experience for cut-off set up and validation will be helpful for other laboratories doing newborn screening test.

A New EGG System Design and Speech Analysis for Quantitative Analysis of Human Glottal Vibration Patterns (성문진동 패턴의 정량적인 해석을 위한 새로운 시스템 설계와 음성분석)

  • 김종찬;이재천;김덕원;오명환;윤대희;차일환
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.427-433
    • /
    • 1999
  • The purpose of the study is to develop an improved pitch extraction method that can be used in a variety of speech applications such as high-puality compression and vocoding, and recognition and synthesis of speech. To do so, we develop a new electroglottograph (EGG) measurement system that is based on the four modulation-demodulation type spot electrodes for detecting the EGG signals. Then, the glottal closure instant(GCI) is determined from the EGG signals on a real-time basis. We can obtain the pitch contour using the information on the GCI. It turns out that the new pitch contour algorithm (PCA) operates more reliably as compared to the conventional speech-only-based algorithm. In addition, we study the speech source models and glottal vibratory patterns for Koreans by measuring and analyzing the diversified vibration patterns of the vocal from the EGG signals.

  • PDF